Paired train-of-four (TOF) and double burst stimuli (DBS) were administered to the ulnar nerve at the wrist in 25 patients (group 1) paralysed with atracurium 0.5 mg kg-1; responses were measured mechanically (except every third DBS response which was manually evaluated). Another 30 patients (group 2) received a DBS every 60 s. A post-tetanic count (PTC) was performed when the first response (D1) was palpated. There was a significant correlation between the twitch heights of the first TOF response (T1) and D1 and likewise between the twitch heights of both second responses (r = 0.9; P less than 0.001), but there was a significant difference in regression coefficients of these two correlations (P less than 0.001). D1 was palpable first with a median PTC of 7. Our results showed that palpation of a single response implied a satisfactory level of paralysis. DBS may be useful for intraoperative clinical monitoring of neuromuscular block.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.