Background Coronary artery calcium (CAC) is an established predictor of future major adverse atherosclerotic cardiovascular events in asymptomatic individuals. However limited data exist as to how CAC compares to functional testing (FT) in estimating prognosis in symptomatic patients. Methods In the Prospective Multicenter Imaging Study for Evaluation of Chest Pain (PROMISE) trial, patients with stable chest pain (or dyspnea) and intermediate pre-test probability for obstructive coronary artery disease (CAD) were randomized to FT (exercise electrocardiography, nuclear stress, or stress echocardiography) or anatomic testing. We evaluated those who underwent CAC testing as part of the anatomic evaluation (n=4,209) and compared to results of FT (n=4,602). We stratified CAC and FT results as normal or mildly, moderately or severely abnormal (for CAC: 0, 1–99 Agatston Score [AS], 100–400 AS and >400 AS, respectively; for FT: normal, mild=late positive treadmill, moderate=early positive treadmill or single-vessel ischemia and severe=large ischemic region abnormality). The primary endpoint was all-cause death, myocardial infarction or unstable angina hospitalization over a median follow-up of 26.1 months. Cox regression models were used to calculate hazard ratios and C-statistic to determine predictive and discriminatory value. Results Overall, the distribution of normal or mildly, moderately or severely abnormal test results was significantly different between FT and CAC (FT = normal 3588 [78.0%], mild 432 [9.4%], moderate 217 [4.7%], severe 365 [7.9%]; CAC = normal 1,457 [34.6%], mild 1340 [31.8%], moderate 772 [18.3%], severe 640 [15.2%], p <0.0001). Moderate and severe abnormalities in both arms robustly predicted events (moderate: CAC HR 3.14, 95% CI 1.81–5.44 and FT HR 2.65, 95% CI 1.46–4.83; severe: CAC HR 3.56, 95% CI 1.99–6.36 and FT HR 3.88, 95% CI 2.58–5.85. In the CAC arm, the majority of events (n=112/133; 84%) occurred in patients with any positive CAC test (score >0) whereas less than half of events occurred in patients with mild, moderate or severely abnormal FT (n=57/132; 43%) (p<0.001). In contrast, any abnormality on FT was significantly more specific for predicting events (78.6% for FT vs 35.2% for CAC, p<0.001). Overall discriminatory ability in predicting the primary endpoint of mortality, nonfatal myocardial infarction, and unstable angina hospitalization was similar and fair for both CAC and FT (c-statistic, 0.67 vs. 0.64). Coronary computed tomographic angiography provided significantly better prognostic information compared to FT and CAC testing (C-index: 0.72). Conclusion Among stable outpatients presenting with suspected CAD, most patients experiencing clinical events have measurable CAC at baseline while less than half have any abnormalities on FT. However, an abnormal FT was more specific for cardiovascular events, leading to overall similarly modest discriminatory abilities of both tests. Clinical Trial Registration URL: https://clinicaltrials.gov; Unique Identifier: NCT01174550
In the past decade, lung transplantation has become established as an accepted therapy for end-stage pulmonary disease. Complications of lung transplantation that may occur in the immediate or longer postoperative term include mechanical problems due to a size mismatch between the donor lung and the recipient thoracic cage; malposition of monitoring tubes and lines; injuries from ischemia and reperfusion; acute pleural events; hyperacute, acute, and chronic rejection; pulmonary infections; bronchial anastomotic complications; pulmonary thromboembolism; upper-lobe fibrosis; primary disease recurrence; posttransplantation lymphoproliferative disorder; and native lung complications such as hyperinflation, malignancy, and infection. Radiologic imaging--particularly chest radiography, computed tomography (CT), and high-resolution CT--is critical for the early detection, evaluation, and diagnosis of complications after lung transplantation. To enable the selection of an effective and relevant course of therapy and, ultimately, to decrease morbidity and mortality among lung transplant recipients, radiologists at all levels of experience must be able to recognize and understand the imaging manifestations of posttransplantation complications.
Lung cancer is the leading cause of cancer-related deaths worldwide, with a dismal 5-year survival rate of 15%. The TNM (tumor-node-metastasis) classification system for lung cancer is a vital guide for determining treatment and prognosis. Despite the importance of accuracy in lung cancer staging, however, correct staging remains a challenging task for many radiologists. The new 7th edition of the TNM classification system features a number of revisions, including subdivision of tumor categories on the basis of size, differentiation between local intrathoracic and distant metastatic disease, recategorization of malignant pleural or pericardial disease from stage III to stage IV, reclassification of separate tumor nodules in the same lung and lobe as the primary tumor from T4 to T3, and reclassification of separate tumor nodules in the same lung but not the same lobe as the primary tumor from M1 to T4. Radiologists must understand the details set forth in the TNM classification system and be familiar with the changes in the 7th edition, which attempts to better correlate disease with prognostic value and treatment strategy. By recognizing the relevant radiologic appearances of lung cancer, understanding the appropriateness of staging disease with the TNM classification system, and being familiar with potential imaging pitfalls, radiologists can make a significant contribution to treatment and outcome in patients with lung cancer.
Purpose:To summarize data on computed tomographic (CT) radiation doses collected from consecutive CT examinations performed at 12 facilities that can contribute to the creation of reference levels. Materials and Methods:The study was approved by the institutional review boards of the collaborating institutions and was compliant with HIPAA. Radiation dose metrics were prospectively and electronically collected from 199 656 consecutive CT examinations in 83 181 adults and 3871 consecutive CT examinations in 2609 children at the five University of California medical centers during 2013. The median volume CT dose index (CTDI vol ), dose-length product (DLP), and effective dose, along with the interquartile range (IQR), were calculated separately for adults and children and stratified according to anatomic region. Distributions for DLP and effective dose are reported for single-phase examinations, multiphase examinations, and all examinations. Results:For adults, the median CTDI vol was 50 mGy (IQR, 37-62 mGy) for the head, 12 mGy (IQR, 7-17 mGy) for the chest, and 12 mGy (IQR, 8-17 mGy) for the abdomen. The median DLPs for single-phase, multiphase, and all examinations, respectively, were as follows: head, 880 mGy · cm (IQR, 640-1120 mGy · cm), 1550 mGy · cm (IQR, 1150-2130 mGy · cm), and 960 mGy · cm (IQR, 690-1300 mGy · cm); chest, 420 mGy · cm (IQR, 260-610 mGy · cm), 880 mGy · cm (IQR, 570-1430 mGy · cm), and 550 mGy · cm (IQR 320-830 mGy · cm); and abdomen, 580 mGy · cm (IQR, 360-860 mGy · cm), 1220 mGy · cm (IQR, 850-1790 mGy · cm), and 960 mGy · cm (IQR, 600-1460 mGy · cm). Median effective doses for single-phase, multiphase, and all examinations, respectively, were as follows: head, 2 mSv (IQR, 1-3 mSv), 4 mSv (IQR, 3-8 mSv), and 2 mSv (IQR, 2-3 mSv); chest, 9 mSv (IQR, 5-13 mSv), 18 mSv (IQR, 12-29 mSv), and 11 mSv (IQR, 6-18 mSv); and abdomen, 10 mSv (IQR, 6-16 mSv), 22 mSv (IQR, 15-32 mSv), and 17 mSv (IQR,(11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)(26). In general, values for children were approximately 50% those for adults in the head and 25% those for adults in the chest and abdomen. Conclusion:These summary dose data provide a starting point for institutional evaluation of CT radiation doses.q RSNA, 2015
ObjectivesThe purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases.MethodsFifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined.ResultsAbnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01).ConclusionOur results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material.
PurposeTo assess cardiothoracic structure and function in patients with pectus excavatum compared with control subjects using cardiovascular magnetic resonance imaging (CMR).MethodThirty patients with pectus excavatum deformity (23 men, 7 women, age range: 14-67 years) underwent CMR using 1.5-Tesla scanner (Siemens) and were compared to 25 healthy controls (18 men, 7 women, age range 18-50 years). The CMR protocol included cardiac cine images, pulmonary artery flow quantification, time resolved 3D contrast enhanced MR angiography (CEMRA) and high spatial resolution CEMRA. Chest wall indices including maximum transverse diameter, pectus index (PI), and chest-flatness were measured in all subjects. Left and right ventricular ejection fractions (LVEF, RVEF), ventricular long and short dimensions (LD, SD), mid-ventricle myocardial shortening, pulmonary-systemic circulation time, and pulmonary artery flow were quantified.ResultsIn patients with pectus excavatum, the pectus index was 9.3 ± 5.0 versus 2.8 ± 0.4 in controls (P < 0.001). No significant differences between pectus excavatum patients and controls were found in LV ejection fraction, LV myocardial shortening, pulmonary-systemic circulation time or pulmonary flow indices. In pectus excavatum, resting RV ejection fraction was reduced (53.9 ± 9.6 versus 60.5 ± 9.5; P = 0.013), RVSD was reduced (P < 0.05) both at end diastole and systole, RVLD was increased at end diastole (P < 0.05) reflecting geometric distortion of the RV due to sternal compression.ConclusionDepression of the sternum in pectus excavatum patients distorts RV geometry. Resting RVEF was reduced by 6% of the control value, suggesting that these geometrical changes may influence myocardial performance. Resting LV function, pulmonary circulation times and pulmonary vascular anatomy and perfusion indices were no different to controls.
Cardiac paragangliomas are among the rarest primary cardiac tumors. We present a case of left atrial paraganglioma in a patient who presented with symptoms and signs of catecholamine excess in which cardiovascular magnetic resonance in multiple orientations and PET-CT played an important role in the diagnosis and tissue characterization.
The increase in radiation exposure due to CT scans has been of growing concern in recent years. CT scanners differ in their capabilities and various indications require unique protocols, but there remains room for standardization and optimization. In this paper we summarize approaches to reduce dose, as discussed in lectures comprising the first session of the 2013 UCSF Virtual Symposium on Radiation Safety in Computed Tomography. The experience of scanning at low dose in different body regions, for both diagnostic and interventional CT procedures, is addressed. An essential primary step is justifying the medical need for each scan. General guiding principles for reducing dose include tailoring a scan to a patient, minimizing scan length, use of tube current modulation and minimizing tube current, minimizing-tube potential, iterative reconstruction, and periodic review of CT studies. Organized efforts for standardization have been spearheaded by professional societies such as the American Association of Physicists in Medicine. Finally, all team members should demonstrate an awareness of the importance of minimizing dose.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.