2009
DOI: 10.1007/s00330-009-1672-3
|View full text |Cite
|
Sign up to set email alerts
|

Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

Abstract: ObjectivesThe purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases.MethodsFifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
76
0
2

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 105 publications
(83 citation statements)
references
References 27 publications
5
76
0
2
Order By: Relevance
“…In patients who cannot perform breath holds, 3D SSFP can acquire images during free breathing utilizing a diaphragm navigator sequence. In some studies, 3D SSFP MRA has actually been demonstrated to provide better measured SNR and CNR compared to CE MRA, with higher image quality of the aortic root (57). One of the drawbacks to 3D SSFP, particularly at 3T, are off resonance artifacts which can manifest as dark bands traversing the images and possibly mimic aortic dissection.…”
Section: Mr Angiography Of the Aortamentioning
confidence: 99%
See 1 more Smart Citation
“…In patients who cannot perform breath holds, 3D SSFP can acquire images during free breathing utilizing a diaphragm navigator sequence. In some studies, 3D SSFP MRA has actually been demonstrated to provide better measured SNR and CNR compared to CE MRA, with higher image quality of the aortic root (57). One of the drawbacks to 3D SSFP, particularly at 3T, are off resonance artifacts which can manifest as dark bands traversing the images and possibly mimic aortic dissection.…”
Section: Mr Angiography Of the Aortamentioning
confidence: 99%
“…2D SSFP was first developed but often has problematic out-ofslice contributions, with suboptimal voxel resolution (57). The development of 3D SSFP greatly minimized these shortcomings to become a valuable NC MRA technique ( Figure 6).…”
Section: Mr Angiography Of the Aortamentioning
confidence: 99%
“…It has demonstrated a higher sensitivity and specificity than other forms of MR imaging and echocardiography. [85] Emergency use of MR is limited. Steady state free procession MR is a newer technology that allows for better visualization of structures by decreasing surrounding interference without the use of contrast.…”
Section: Imaging Of the Aortic Rootmentioning
confidence: 99%
“…A rapid morphologic assessment can be achieved in urgent situations, such as demonstrating aortic abnormalities in unstable patients, for example intimal flaps and false lumens in aortic dissection (Pereles, 2002;Gebker, 2007). Free-breathing cardiac and respiratory-gated 3D SSFP MRA has also been shown valuable in the evaluation of thoracic vessels (Fuchs, 2003;Krishnam, , 2010, and represents an alternative for free-breathing SSFP MRA. SSFP sequences can also be acquired in a cine mode, and have become the foundation for cine imaging.…”
Section: "Bright Blood" Mr Angiographymentioning
confidence: 99%