Effective arterial elastance (Ea) is the coupling parameter between the left ventricle and peripheral circulation in normal subjects. If left ventricular end systolic pressure (Pes), contractility (Es) and Ea are known, left ventricular end diastolic volume (LVEDV) and ejection fraction of the ventricle are completely determined. The aim of this study was to give an analytical expression for Ea in patients with mitral and aortic regurgitation, and predict both LVEDV and the effect of vasodilator therapy on LVEDV. Twenty-three subjects with atypical chest pain, 15 patients with mitral insufficiency and 11 with aortic insufficiency underwent diagnostic cardiac catheterization, coronary angiography, and left ventricular cineangiography, which was analyzed quantitatively. Ea was 2.05 +/- 0.63 in normal subjects, while it was 1.28 +/- 0.71 and 1.57 +/- 0.87 in patients with mitral and aortic insufficiency, respectively. All these groups differed with ANOVA test (p = 0.0031). We tested the ability of the analytical expressions for Ea in normal subjects, and patients with mitral insufficiency or aortic insufficiency to predict measured Ea and LVEDV. Ea and LVEDV were predicted rather accurately in every case (p < 0.0001). We used published data to test the effect of resistance modulation on LVEDV. Predicted and measured LVEDV were linearly correlated both in aortic (p < 0.0001) and mitral insufficiency (p = 0.027). Moreover, in some cases a left ventricular enlargement after vasodilator therapy could be anticipated because of an unbalanced decrease in resistance and heart rate. Ea seems to be the coupling parameter between the left ventricle and the peripheral circulation not only in normal subjects, but also in patients with mitral or aortic regurgitation; its measurement before administering vasodilating drugs may be useful in order to predict the effects on LVEDV, and achieve an optimal ventriculoarterial coupling.
Both single- and dual-coil transvenous ICD lead systems were associated with high rates of successful ICD implantation, and we found no significant differences in ventricular arrhythmias interruption between the two ICD lead systems configuration. Instead, anodal defibrillation was more likely to be successful than cathodal defibrillation.
Thoracic vein aneurysms are very rare vascular lesions, usually detected as incidental findings. We describe the case of a patient with an advanced atrioventricular block who underwent definitive pacemaker implantation. In order to explain the difficult advancement of a pacemaker lead, vein angiography was performed during the procedure and a large innominate vein aneurysm was observed. Successful lead placement was then performed without further complications. (PACE 2008; 31:627-629)
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.