Background-There is a lack of information on the incidence and predictors of early mortality at 30 days and late mortality between 30 days and 1 year after transcatheter aortic valve implantation (TAVI) with the self-expanding CoreValve Revalving prosthesis. Methods and Results-A total of 663 consecutive patients (mean age 81.0Ϯ7.3 years) underwent TAVI with the third generation 18-Fr CoreValve device in 14 centers. Procedural success and intraprocedural mortality were 98% and 0.9%, respectively. The cumulative incidences of mortality were 5.4% at 30 days, 12.2% at 6 months, and 15.0% at 1 year.
In myocarditis, biventricular dysfunction at diagnosis was the main predictor of death/transplantation. AHA identified immune-mediated myocarditis in the majority of cases. Viral genome was a univariate predictor of adverse prognosis. Our approach of using AHA and positive PCR as aetiopathogenetic markers should help patient selection and recruitment in future studies on aetiological therapy.
Background—
Three-dimensional electroanatomic voltage mapping offers the potential to identify low-voltage areas that correspond to regions of right ventricular (RV) myocardial loss and fibrofatty replacement in patients with arrhythmogenic RV cardiomyopathy/dysplasia (ARVC/D).
Methods and Results—
Thirty-one consecutive patients (22 men and 9 women; mean age, 30.8±7 years) who fulfilled the criteria of the Task Force of the European Society of Cardiology and International Society and Federation of Cardiology (ESC/ISFC) for ARVC/D diagnosis after noninvasive clinical evaluation underwent further invasive study including RV electroanatomic voltage mapping and endomyocardial biopsy (EMB) to validate the diagnosis. Multiple RV endocardial, bipolar electrograms (175±23) were sampled during sinus rhythm. Twenty patients (group A; 65%) had an abnormal RV electroanatomic voltage mapping showing ≥1 area (mean 2.25±0.7) with low-voltage values (bipolar electrogram amplitude <0.5 mV), surrounded by a border zone (0.5 to 1.5 mV) that transitioned into normal myocardium (>1.5 mV). Low-voltage electrograms appeared fractionated with significantly prolonged duration and delayed activation. In 11 patients (group B; 35%), electroanatomic voltage mapping was normal, with preserved electrogram voltage (4.4±0.7 mV) and duration (37.2±0.9 ms) throughout the RV. Low-voltage areas in patients from group A corresponded to echocardiographic/angiographic RV wall motion abnormalities and were significantly associated with myocyte loss and fibrofatty replacement at EMB (
P
<0.0001) and familial ARVC/D (
P
<0.0001). Patients from group B had sporadic disease and histopathological evidence of inflammatory cardiomyopathy (
P
<0.0001). During the time interval from onset of symptoms to the invasive study, 11 patients (55%) with electroanatomic low-voltage regions received an implantable cardioverter/defibrillator because of life-threatening ventricular arrhythmias, whereas all but 1 patient with a normal voltage map remained stable on antiarrhythmic drug therapy (
P
=0.02).
Conclusions—
Three-dimensional electroanatomic voltage mapping enhanced accuracy for diagnosing ARVC/D (1) by demonstrating low-voltage areas that were associated with fibrofatty myocardial replacement and (2) by identifying a subset of patients who fulfilled ESC/ISFC Task Force diagnostic criteria but showed a preserved electrogram voltage, an inflammatory cardiomyopathy mimicking ARVC/D, and a better arrhythmic outcome.
Background-Transcatheter aortic valve implantation (TAVI) is a new option for patients with severe aortic stenosis at high surgical risk. The standard retrograde approach through the femoral artery is contraindicated in case of unfavorable iliofemoral anatomy or extensive disease. In these patients, a trans-subclavian approach may be feasible. No specific complications for the subclavian access (vessel rupture, vertebral or internal mammary ischemia) were reported. The learning curve for the subclavian approach led to a wider use of local anesthesia. Thirty-day mortality was 0% versus 6.1% in the subclavian versus femoral groups, respectively (Pϭ0.13). Six-month mortality rate was 9.4% versus 15.8% (Pϭ0.44), whereas valve-related adverse events were 13.6% versus 13.9% (Pϭ0.79). Conclusions-TAVI through the subclavian approach appeared feasible and safe, with excellent procedural success and low in-hospital complication rates. This new technique allows patients with contraindications to the femoral approach to be treated with TAVI. (Circ Cardiovasc Interv. 2010;3:359-366.)
Methods and Results-Between
An "aggressive" diagnostic approach, requiring coronary angiography in asymptomatic DM2 patients with < or =1 associated RF for CAD and abnormal MCE, identified patients with a subclinical CAD characterized by a more favorable angiographic anatomy. The criterion of > or =2 RFs did not help to identify asymptomatic patients with a higher prevalence of CAD and is only related to a more severe CAD with unfavorable coronary anatomy.
An early/minor form of ARVC/D may mimic idiopathic RVOT tachycardia. Electroanatomical voltage mapping is able to identify RVOT tachycardia due to concealed ARVC/D by detecting RVOT electroanatomical scars that correlate with fibrofatty myocardial replacement at EMB and predispose to sudden arrhythmic death.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.