Our study provides normative values for RA volumes and function measured by 3DE and 2D-STE in a relatively large cohort of healthy subjects with a wide age range. These data will help clinicians to identify RA remodelling and dysfunction.
Accordingly, in this prospective study, we aimed to (1) assess the presence and extent of measurement variability in relation to the various methods and definitions of RVLS, Background-Despite the fact that assessment of right ventricular longitudinal strain (RVLS) carries important implications for patient diagnosis, prognosis, and treatment, its implementation in clinical settings has been hampered by the limited reference values and the lack of uniformity in software, method, and definition used for measuring RVLS. Accordingly, this study was designed to establish (1) the reference values for RVLS by 2-dimensional speckle-tracking echocardiography; and (2) their relationship with demographic, hemodynamic, and cardiac factors. Methods and Results-In 276 healthy volunteers (55% women; age, 18-76 years), free wall and septum RVLS (6 segments) and free wall RVLS (3 segments) using both 6-and 3-segment regions of interest were obtained. Feasibility of 6-segment RVLS was 92%. Free wall RVLS from 3-versus 6-segment regions of interest had similar values, yet 6-segment region of interest was more feasible (86% versus 73%; P<0.001) and reproducible. Reference values (lower limits of normality) were as follows: 6-segment RVLS, −24.7±2.6% (−20.0%) for men and −26.7±3.1% (−20.3%) for women; 3-segment RVLS, −29.3±3.4% (−22.5%) for men and −31.6±4.0% (−23.3%) for women (P<0.001). Free wall RVLS was 5±2 strain units (%) larger in magnitude than 6-segment RVLS, 10±4% larger than septal RVLS, and 2±4% larger in women than in men (P<0.001). At multivariable analysis, age, sex, pulmonary systolic pressure, right atrial minimal volume, as well as right atrial and left ventricular longitudinal strain resulted as correlates of RVLS values. Conclusions-This is the largest study providing sex-and method-specific reference values for RVLS. Our data may foster the implementation of 2-dimensional speckle-tracking echocardiography-derived RV analysis in clinical practice.(Circ Cardiovasc Imaging. 2016;9:e003866.
Novel vendor-independent 3DE software enables an accurate, reproducible and faster quantitation of RV volumes and ejection fraction. Rather than optional, systematic verification of border tracking quality and manual editing are mandatory to ensure accurate 3DE measurements. These findings are relevant for echocardiography laboratories aiming to implement 3DE for RV analysis for both research and clinical purposes.
Apart from Lε, the inter-vendor agreement of Rε, Cε and Aε measured with Artida and VividE9 was poor. Reference values should be specific for each system and baseline and follow-up data in longitudinal studies should be obtained using the same 3D STE platform.
Background-Bridging therapy with low-molecular-weight heparin is usually recommended in patients who must stop oral anticoagulants before surgical or invasive procedures. To date, there is no universally accepted bridging regimen tailored to the patient's thromboembolic risk. This prospective inception cohort management study was designed to assess the efficacy and safety of an individualized bridging protocol applied to outpatients. Methods and Results-Oral anticoagulants were stopped 5 days before the procedure. Low-molecular-weight heparin was started 3 to 4 days before surgery and continued for 6 days after surgery at 70 anti-factor Xa U/kg twice daily in high-thromboembolic-risk patients and prophylactic once-daily doses in moderate-to low-risk patients. Oral anticoagulation was resumed the day after the procedure with a boost dose of 50% for 2 days and maintenance doses afterward. The patients were followed up for 30 days. Of the 1262 patients included in the study (only 15% had mechanical valves), 295 (23.4%) were high-thromboembolic-risk patients and 967 (76.6%) were moderate-to low-risk patients. In the intention-to-treat analysis, there were 5 thromboembolic events (0.4%; 95% confidence interval, 0.1 to 0.9), all in high-thromboembolic-risk patients. There were 15 major (1.2%; 95% confidence interval, 0.7 to 2.0) and 53 minor (4.2%; 95% confidence interval, 3.2 to 5.5) bleeding episodes. Major bleeding was associated with twice-daily low-molecular-weight heparin administration (high-risk patients) but not with the bleeding risk of the procedure. Conclusions-This management bridging protocol, tailored to patients' thromboembolic risk, appears to be feasible, effective, and safe for many patients, but safety in patients with mechanical prosthetic valves has not been conclusively established.
A multicenter, observational, retrospective, cross-sectional study of patients, receiving oral anticoagulation therapy (OAT) for stroke prophylaxis in chronic non-valvular atrial fibrillation (NVAF) was conducted in the US, Canada, France, Italy and Spain according to their predominant model of care [routine medical care (RMC) or Anticoagulation Clinic care (ACC)]. The study objectives were to assess anticoagulation control (time in target range), and to describe the features of the local model of care. Consecutive patients were recruited on the basis of a minimum of 60 days of oral anticoagulant treatment over a 12 month period, and clinic and physician details were captured by means of a structured face-to-face or telephone interview. Time in therapeutic range (TTR) was calculated by using linear interpolation between INR values. A total of 1511 patients were recruited, of whom 1445 were included in the analysis of TTR. TTR was higher in ACC (69.5% and 64.9% for Italy and Spain, respectively) with respect to RMC (58.1%, 62.8% and 59.3% for the US, Canada and France, respectively). Mean intervals between INR determinations were between 3 and 4 weeks. Dose changes in case of INR outside therapeutic range were more frequent in Spain and less frequent in France. Striking differences were observed in type of VKA used, specialists involved in patient management, and dosage instructions. Studying of anticoagulation management based on local models of care highlights important discrepancies among countries and suggests further standardization of the management of this important therapy is necessary.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.