Purpose. To evaluate the corneal endothelial cell density and morphology in normal Egyptian eyes. Methods. In total, 568 healthy eyes of 568 Egyptian volunteers aged 20 to 85 years were examined using noncontact specular microscopy for the central corneal thickness (CCT), mean endothelial cell density (MCD), coefficient of variation (CV) in cell area, mean cell area (MCA), and hexagonal cell (Hex) percentage. Variables were compared between sexes and between different age groups. Results. The mean CCT, MCD, and MCA were 514.45 ± 43.04 μm, 2647.50 ± 382.62 cells/mm2, and 390.59 ± 149.94 μm2, respectively. MCD and MCA showed no significant differences between men and women (P=0.171 and 0.099, respectively), whereas CV (%) and Hex (%) showed significant differences (P=0.024 and 0.015, respectively). CCT (P=0.007, r = −0.113) and MCD (P<0.001, r = −0.357) exhibited a significant negative correlation with age, whereas CV (%) (P<0.001, r = 0.341) and MCA (P=0.008, r = 0.111) exhibited a significant positive correlation. The mean rate of endothelial cell loss from 20 to 85 years of age was 0.3% per year. Conclusions. Our results provide normative data for the corneal endothelium in healthy Egyptian eyes, thus increasing the knowledge base for corneal endothelial cell parameters in healthy Egyptian eyes. Furthermore, our findings can be used as baseline values for comparisons between Egyptian and other populations and for studies of the endothelial cell reserve and capacity for intraocular surgery and corneal transplantation.
Purpose. To examine the morphological changes in the meibomian glands of patients with keratoconus as well as to study the relationship between these changes in the morphology and several tear film parameters. Methods. Examination of the meibomian gland (MG) of 300 keratoconus patients presenting to the center using infrared noncontact meibography system (Sirius, CSO, Italy) between January 2017—January 2019. 100 eyes of healthy individuals were also enrolled as a control group. Tear breakup time (TBUT) test and Schirmer test II were evaluated. Subjective symptoms were also assessed using Ocular Surface Disease Index (OSDI). Results. Mean age of keratoconus patients was 19 ± 12 years and 21 ± 14 years in control group. Average TBUT was 4.9 ± 2.1 sec. and average Schirmer test was 5.3 ± 2.2 mm which was significantly lower than control group (p=0.05). Meibomian gland dropout in the lower eyelid of the keratoconus group was as follows: grade 0 (no loss of meibomian glands): 100 eyes; grade 1 (gland dropout area <1/3 of the total meibomian glands): 85 eyes; grade 2 (gland dropout area 1/3 to 2/3): 68 eyes; and grade 3 (gland dropout >2/3): 47 eyes. Conclusion. Keratoconus shows significant meibomian gland dropout and distortion that can be recorded by noncontact meibography. Sirius meibography is a simple, cost-effective method of evaluating meibomian gland dropout as a part of the routine refractive examination.
Purpose. To study the relation between the serum 25-hydroxyl vitamin D (OH D) level and the occurrence of age-related cataract in a case-control study. Patients and Methods. 325 cataract patients and 385 control individuals of both sexes were examined for the 25-OH D level using the chemiluminescent microparticle immunoassay (CMIA) technology. Results. Mean 25-OH D level in cataract patients was 7.6 ± 5.5 ± 11.2 ng/mL and median was 5.6 (2.6–31.9), while in the control group, mean 25-OH D level was 18.5 ± 9.6 ng/mL and median was 17.8 (3.4–37.8) (p value < 0.001). There was a statistically significant difference among the different types of cataracts with the lowest level in nuclear cataract. Conclusion. 25-OH D levels in all enrolled individuals were below the reference levels with a severe deficiency in cataract patients. These results might highlight the role of deficiency of 25-OH D in age-related cataract patients.
Purpose To evaluate the outcomes of femtosecond laser-assisted implantation of a 355-degree intracorneal ring (ICR) (Keraring) in patients with keratoconus in the three-year follow-up. Setting Future Femtolaser Center, Sohag, Egypt. Design Prospective interventional case series. Patients and Methods A prospective case series of 38 eyes of 26 patients with keratoconus had implantation of the 355-degree ICR keraring after tunnel creation with a femtosecond laser. The uncorrected visual acuities (UCVA) and best-corrected visual acuities (BCVA), sphere, cylinder, and manifest refraction spherical equivalent (SE), and mean keratometry (K), K max, and K min were evaluated preoperatively and 3, 6, 12, 24, and 36 months postoperatively, and all complications were reported. Results 38 eyes of 26 patients with mean age 25.92 ± 5.44 years were enrolled in the study, 11 were males (42.3%). The mean UCVA improved from 0.93 ± 0.21 to 0.63 ± 0.21 logMAR (P ≤ 0.001) and the mean BCVA from 0.67 ± 0.22 to 0.43 ± 0.26 logMAR (P < 0.001). The mean sphere, cylinder, and spherical equivalent have been changed dramatically from preoperative to 3 month postoperative, which is statistically significant (P ≤ 0.001), and the changes between 1 and 2 years and 2 and 3 years are also considerable and statistically significant; the K max and K min and K mean improved and the changes were statistically significant (P ≤ 0.001), and the changes between one, two, and three years were also statistically significant. The safety and efficacy indices were changed through the three-year follow-up. The complications were corneal neovascularization (36.84%), corneal melting (26.3%), and ring extrusion (31.5%) at the end of the study. Conclusions Implantation of a 355-degree intracorneal keraring using femtosecond laser improved the visual, refractive, and topographic parameters in keratoconus patients, with a high rate of ICR extrusion and instability. The study has been registered for the Pan African Clinical Trial Registry (http://www.pactr.org) database within No: PACTR201810796878908 on 29 October 2018.
Background To document the visual acuity, spectral domain optical coherence tomography (SD-OCT) findings and prognosis in10 eyes of 6 patients with foveal damage from solar retinopathy in 1 year. Methods This was a prospective, observational case series of patients presented by solar maculopathy at Ophthalmology department, Sohag University. All patients underwent visual acuity (VA) testing, refraction, dilated fundus examination fluorescein angiography (FA) and SD-OCT (spectral Domain ocular coherence Tomography) imaging and follow up for 1 year. Results The mean age was 16.5 years (range 9–27 years, both eyes are affected in 4 patients. The mean spherical equivalent (SE) was – 0.25 ± 0.50 D. The visual acuity of the affected eyes ranged from 0.4 to 0.9 on presentation. At presentation Significant foveal pathology was identified on SD-OCT in 10 eyes, All eyes showed disruption of the photoreceptor ellipsoid zone and the interdigitation zone on SD-OCT, Follow up of the cases continued for 1 year.100% of cases showed improvement in VA: 20% eyes regained 1, 50% eyes with VA of 0.9; two eyes 20% 0.8 and one eyes (10%) with 0.4. The improvement began after 1 week and reached its maximum and became stationary after the 6th month of follow up, the outer retinal hole persist in OCT in 80% of cases. Conclusion Solar maculopathy has a good prognosis yet shows no improvement after 6 months. Young age might pose as a risk factor.
Purpose. To evaluate the prevalence, possible risk factors, and clinical results of femtosecond laser implanted intrastromal corneal ring segment (ICRS) extrusion in keratoconic eyes. Patients and Methods. This is a retrospective observational study evaluating 333 eyes of 269 patients who were subjected to femtosecond laser-implanted Keraring ICRS in the Sohag Refractive Center, Sohag, Egypt, from January 2014 to January 2019. The study included eyes with channels created by a femtosecond laser (60 kHz IntraLase femtosecond system; Advanced Medical Optics, Santa Ana, California, USA) with implantation of Keraring intrastromal corneal ring segments (Mediphacos, Belo Horizonte, Brazil). Patient data and causes of Keraring extrusions were identified as being those rings that migrated or showed melting of the cornea with no other reason which required segment removal. Results. Seven eyes were found to fit the criteria of ring extrusion (2.1%) out of the 333 eyes which had Keraring implantation. All extruded rings were from patients with keratoconus grade 3, with eccentric cones, and with femtosecond creation of the tunnel. Four eyes belonging to 3 patients (57.1%) had a history of vernal Keratoconjunctivitis, yet they did not show signs of activity at the time of implantation. They reported excessive rubbing just before they presented with conjunctival hyperemia and foreign body sensation. Five eyes (71.4%) showed chronic sun exposure. The mean minimal corneal thickness was 401.85 μm (range 384–420 μm), while the mean maximum keratometry was 61 D (range 55.18–68.96 D). Most of the extruded rings had large arcs. Six eyes had crosslinking (CXL) at the same session of the Keraring implantation. The simultaneous CXL treatment is considered as a possible significant risk factor for ring extrusion. Conclusion. ICRS is an effective reversible option for patients with keratoconus who are intolerant to hard contact lenses, yet the choice of cases and ring segments is mandatory for satisfactory results. Moreover, meticulous history taking and examination reduces the incidence of complications including extrusion.
PurposeTo compare the efficacy and outcome of phakic toric implantable collamer lens (TICL) and refractive clear lens extraction with AcrySof Toric intraocular lens (TIOL) implantation for the treatment of myopic astigmatism.Patients and methodsThis study assessed eyes with myopic astigmatism >−1 D and ≤−4 D with a spherical equivalent >10 D or <10 D if the patients were unsuitable for corneal refractive surgery. These eyes were divided into group A, in which Visian Toric ICL™ Phakic TICL was implanted, and group B, which involved clear lens extraction with implantation of an AcrySof IQ toric SN60T3-9™ IOL. The outcome and complications were evaluated.ResultsThis study enrolled 63 eyes of 38 patients with a follow-up period of at least 6 months. The mean postoperative spherical equivalent was −0.19±0.31 D in group A and −0.21±0.28 D in group B (P=0.69). The mean postoperative cylinder value was −0.46±0.53 D in group A and −0.32±0.41 D in group B (P=0.35). Postoperative cylinder was <1 D in 76.47% and 79.31% of eyes in groups A and B, respectively. The mean endothelial cell count was reduced by 4.32% in group A and by 5.32% in group B (P=0.003). The mean postoperative intraocular pressure increased insignificantly in group A (P=0.22) and reduced significantly in group B (P=0.004). The complication rate was 11.76% in group A and 6.90% in group B.ConclusionBoth procedures showed predictable results and good visual results. However, the loss of accommodation and risk of retinal complications in the TIOL group suggest that the use of TICL for myopic astigmatism is a better choice in younger patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.