The application of THz to medical imaging is experiencing a surge in both interest and federal funding. A brief overview of the field is provided along with promising and emerging applications and ongoing research. THz imaging phenomenology is discussed and tradeoffs are identified. A THz medical imaging system, operating at ~525 GHz center frequency with ~125 GHz of response normalized bandwidth is introduced and details regarding principles of operation are provided. Two promising medical applications of THz imaging are presented: skin burns and cornea. For burns, images of second degree, partial thickness burns were obtained in rat models in vivo over an 8 hour period. These images clearly show the formation and progression of edema in and around the burn wound area. For cornea, experimental data measuring the hydration of ex vivo porcine cornea under drying is presented demonstrating utility in ophthalmologic applications.
Robot-assisted minimally invasive surgery has gained widespread use over the past decade, but the technique is currently operated in the absence of haptic feedback during tissue manipulation. We have developed a complete tactile feedback system, consisting of a piezoresistive force sensor, control system, and pneumatic balloon tactile display, and mounted directly onto a da Vinci surgical robotic system. To evaluate the effect of tactile feedback on robotic manipulation, a group of novices (n = 16) and experts ( n = 4) were asked to perform three blocks of peg transfer tasks with the tactile feedback system in place. Force generated at the end-effectors was measured in all three blocks, but tactile feedback was active only during the middle block. All subjects used higher force when the feedback system was inactive. When active, subjects immediately used substantially less force and still maintained appropriate grip during the task. After the system was again turned off, grip force increased significantly to prefeedback levels. These results demonstrate that robotic manipulations without tactile feedback are done with more force than needed to grasp objects. Therefore, the addition of tactile feedback allows the surgeon to grasp with less force, and may improve control of the robotic system and handling of tissues and other objects.
A haptic feedback system has been developed to provide sensory information to patients with lower-limb prostheses or peripheral neuropathy. Piezoresistive force sensors were mounted against four critical contact points of the foot to collect and relay force information to a system controller, which in turn drives four corresponding pneumatically controlled balloon actuators. The silicone-based balloon actuators were mounted on a cuff worn on the middle thigh, with skin contacts on the posterior, anterior, medial, and lateral surfaces of the thigh. Actuator characterization and human perceptual testing were performed to determine the effectiveness of the system in providing tactile stimuli. The actuators were determined to have a monotonic input pressure-vertical deflection response. Six normal subjects wearing the actuator cuff were able to differentiate inflation patterns, directional stimuli and discriminate between three force levels with 99.0%, 94.8%, and 94.4% accuracy, respectively. With force sensors attached to a shoe insole worn by an operator, subjects were able to correctly indicate the movements of the operator with 95.8% accuracy. These results suggest that the pneumatic haptic feedback system design is a viable method to provide sensory feedback for the lower limbs.
This work introduces the potential application of terahertz (THz) sensing to the field of ophthalmology, where it is uniquely suited due to its nonionizing photon energy and high sensitivity to water content. Reflective THz imaging and spectrometry data are reported on ex-vivo porcine corneas prepared with uniform water concentrations using polyethylene glycol (PEG) solutions. At 79% water concentration by mass, the measured reflectivity of the cornea was 20.4%, 14.7%, 11.7%, 9.6%, and 7.4% at 0.2, 0.4, 0.6, 0.8, and 1 THz, respectively. Comparison of nine corneas hydrated from 79.1% to 91.5% concentration by mass demonstrated an approximately linear relationship between THz reflectivity and water concentration, with a monotonically decreasing slope as the frequency increases. The THz-corneal tissue interaction is simulated with a Bruggeman model with excellent agreement. THz applications to corneal dystrophy, graft rejection, and refractive surgery are examined from the context of these measurements.
A reflective pulsed terahertz imaging system based on direct detection was developed and used to obtain high-resolution images of a porcine skin specimen with superficial partial-thickness (second-degree) burns. Images were also obtained of the sample through ten layers of dry medical (cotton) gauze with minimal image degradation. The burned and unburned regions of skin had large differences in terahertz reflectivity, displaying clear delineation [20 dB signal-to-noise ratio (SNR) difference signal] between both regions in the images. The terahertz images also exhibited a "halo" surrounding the burn areas that may correlate to the extent of burn injury. The system operated at a center frequency of 500 GHz with 125 GHz of 3 dB bandwidth and used whiskbroom scanning to generate images with a spatial resolution of 1.5 mm. Each pixel was acquired with a 16 ms integration time, resulting in a 40 dB postdetection SNR. The simplicity and high SNR of the reflective terahertz system are promising steps toward real-time terahertz medical imaging.
A unique ultrasound dental crack detection system using a novel transducer; a novel coupling agent; and customized electronic and digital signal processing (DSP) algorithms has been validated in a simulated tooth.
The da Vinci Surgical System provided adequate dexterity for performing delicate intraocular manipulations. In the current design, the kinematics of the robotic arms was found to be insufficient for standard intraocular surgery. The system's endoscope did not did not yield the same detail acquired by an ophthalmic microscope.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.