2010
DOI: 10.1016/j.ultrasmedbio.2010.02.012
|View full text |Cite
|
Sign up to set email alerts
|

A Review of Tissue Substitutes for Ultrasound Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

13
372
0
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 538 publications
(410 citation statements)
references
References 93 publications
13
372
0
1
Order By: Relevance
“…Copolymer-in-oil TMM phantoms can achieve optimal mechanical properties (Oudry et al, 2009); however, the range of acoustic velocities achievable with this material (1420 -1464 m/s) is much lower than that of soft tissue (Szabo, 2004). Polyarcylamide gel requires special precautions during preparation due to its toxicity (Culjat et al, 2010), and in addition the material has been reported as fragile (Oudry et al, 2009). …”
Section: Introductionmentioning
confidence: 99%
“…Copolymer-in-oil TMM phantoms can achieve optimal mechanical properties (Oudry et al, 2009); however, the range of acoustic velocities achievable with this material (1420 -1464 m/s) is much lower than that of soft tissue (Szabo, 2004). Polyarcylamide gel requires special precautions during preparation due to its toxicity (Culjat et al, 2010), and in addition the material has been reported as fragile (Oudry et al, 2009). …”
Section: Introductionmentioning
confidence: 99%
“…Elastic properties of the material (gel) are also able to be known here as the compressibility of the material. Regarding to equation (2), an increase in elastic modulus will result in increase in the acoustic speed, compared to density because the compressibility plays more important role to determine the sound speed through media An increase in density which should leads to decrease in the propagation speed as in Figure 2 (a), actually didn't affect much of the value of the sound speed. Every five days each, the physical condition of those polymer gels was being observed while the sound speed was measured.…”
Section: Resultsmentioning
confidence: 99%
“…In the range of medical application, there are some tissues phantoms available commercially [2]. The comparison between the multipurpose manufactured phantoms such as (Zerdine TM from CIRS Inc., condensed-milk-based gel from Gammex RMI and urethane-rubber-based from ATSLabs) [3]were made, this fabricated phantom has several advantages, i.e the phantom is easily made, low cost, less fragile, and the preparation using less hazardous chemical, and can last within three weeks (23 days) based on visual inspection from the ultrasound image and direct observation.…”
Section: Introductionmentioning
confidence: 99%
“…The backscatter properties of the tissue‐mimicking material in the CIRS 047 are not mentioned in the specification from the manufacturer other than “scatter controlled independently from attenuation”. The backscatter coefficient is difficult to measure accurately and is therefore rarely reported in the literature (23) . Nevertheless, the amount of scatter in the phantom results in images with a soft‐tissue‐like appearance.…”
Section: Discussionmentioning
confidence: 99%