PurposeThe purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B).MethodsThis prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve.ResultsPostoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare.ConclusionBoth groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm.
PurposeTo compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye.MethodsThis prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve.ResultsPostoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision.ConclusionBoth lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions.
PURPOSE: To compare the accuracy of Optiwave Refractive Analysis (ORA) intraoperative aberrometry (Alcon Laboratories, Inc., Fort Worth, TX) with preoperative biometry in predicting residual refractive error after cataract surgery in eyes that underwent radial keratotomy. METHODS: This was a prospective consecutive case series of patients with cataract and prior radial keratotomy. Each patient underwent a preoperative intraocular lens (IOL) power calculation using partial coherence interferometry (IOLMaster version 5; Carl Zeiss Meditec, Jena, Germany). For each eye, the Barrett True-K formula was used to select an IOL targeting emmetropia. Residual refractive error was predicted preoperatively using the SRK/T, Hoffer Q, Haigis, and Holladay formulas 1 and 2, and the ORA intraoperatively. Between 8 and 12 weeks after cataract extraction with IOL implantation, the postoperative refraction was compared with the preoperative and intraoperative predictions. RESULTS: The study comprised 52 eyes of 34 patients. The median absolute errors associated with each method were as follows: Barrett True-K formula (0.34), ORA aberrometer (0.53), and SRK/T (0.54), Hoffer Q (0.51), Haigis (0.54), SRK/T (0.57), and Holladay formulas 1 and 2 (0.44) ( P = .08). The proportion of patients within ±0.50 diopters of the predicted error was 63.5%, 48.1%, 44.2%, 48.1%, 53.8%, 36.5%, and 57.7%, respectively ( P = .03). No statistically significant difference was observed in the number of eyes with hyperopic outcomes ( P = .68). CONCLUSIONS: In eyes with prior radial keratotomy surgery, the ORA aberrometer performance was similar to the Barrett True-K formula and all of the other established formulas, with no significant difference between median absolute error and mean absolute error. The Barrett True-K formula produced significantly more eyes within ±0.50 diopters than the SRK/T, Hoffer Q, and Holladay 1 formulas. [ J Refract Surg. 2019;35(10):656–661.]
Purpose: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. Methods: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), and distance-corrected intermediate visual acuity (DCIVA), with analysis of contrast sensitivity (CS), wavefront, and visual defocus curve. Results: Postoperative UDVA was 0.09 and 0.08 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.868); postoperative CDVA was 0.04 and 0.02 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.68); DCIVA was 0.17 and 0.54 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.000); and DCNVA was 0.04 and 0.09 logMAR in the SN6AD1 and ZMB00 groups, respectively (p=0.001). In both cases, there was an improvement in the spherical equivalent and UDVA (p<0.05). Under photopic conditions, the SN6AD1 group had better CS at low frequencies without glare (p=0.04); however, the ZMB00 group achieved better sensitivity at high frequencies with glare (p=0.003). The SN6AD1 and ZMB00 lenses exhibited similar behavior for intermediate vision, according to the defocus curve; however, the ZMB00 group showed a shorter reading distance than the SN6AD1 group. There were no significant differences regarding aberrometry between the two groups. Conclusion: Both lenses promoted better quality of vision for both long and short distances and exhibited a similar behavior for intermediate vision. The SN6AD1 and ZMB00 groups showed better results for CS under photopic conditions at low and high spatial frequencies, respectively. Keywords
PurposeThe purpose of this study was to compare intraoperative parameters between femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification using Centurion® Vision System with Active Fluidics.SettingThis study was performed at Brasília Ophthalmologic Hospital, Brasília, Federal District, Brazil.Patients and methodsThis was a prospective randomized comparative study. Patients with the diagnosis of cataract and surgical extraction programmed were divided into two groups: conventional phacoemulsification and FLACS. Intraoperative data were collected and submitted for statistical analysis.ResultsA total of 400 eyes were enrolled, 200 in each group. There were no surgical complications. Groups were statistically equivalent in age and nucleus density. Cumulative dissipated energy and torsional time were significantly reduced in the FLACS group. Conventional surgery had less fluid usage, total case time and aspiration (ASP) time.ConclusionFLACS with Active Fluidics System can reduce the ultrasound energy use during cataract surgery, in spite of increasing case time, fluid usage and ASP time.
The aim of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of an extended depth of focus intraocular lens, J&J Vision Tecnis Symfony ® ZXR00 (Group A) and bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ PanOptix ® TNFT00 (Group B). Methods: This prospective, nonrandomized, comparative study of consecutive cases assessed 52 eyes of 26 patients operated on by the same surgeon (WTH) and binocularly implanted with multifocal intraocular lenses between May 2016 and July 2018. Binocular visual acuity for far, intermediate and near was tested in all cases. Ophthalmological evaluation included the measurement of binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA) at 40 cm, uncorrected intermediate visual acuity (UIVA) at 70 cm, monocular visual defocus curve and the quality of life (QoL) questionnaire, National Eye Institute Visual Functioning Questionnaire-25 (NEI-VFQ 25). Results: Postoperative UDVA was 0.00 and 0.09 logMAR (P<0.001), UIVA was 0.20 and 0.39 logMAR (P<0.001) and UNVA was 0.16 and −0.01 logMAR (P<0.001) in groups A and B, respectively; postoperative CDVA was −0.05 and 0.06 logMAR (P<0.001) in groups A and B, respectively. Conclusion: Both groups reported good subjective quality of vision regarding long, intermediate and short distances. Group A had a better performance for binocular UDVA, UIVA at 70 cm and CDVA, while regarding the monocular defocus curve, Group A outperformed Group B for long distances. Furthermore, Group B surpassed it in the short to very short distances, between the range of ≥2.00 D to 5.00 D of vergence. While Group A had a better performance regarding the vergences between 0.00 and 1.00 D (P<0.05) and at the vergence of +2.50 D (P=0.007). Group B outran Group A for UNVA at 40 cm.
PurposeTo compare intraoperative parameters between venturi and peristaltic pump in WhiteStar Signature® phacoemulsification machine using the bevel-down technique.SettingHospital Oftalmológico de Brasília, Brasília, Federal District, Brazil.DesignProspective, comparative, patient-masked study.MethodsThree hundred eyes were randomly assigned to have a phacoemulsification procedure with WhiteStar Signature® using either peristaltic (n=150 eyes) or venturi (n=150 eyes) pumps by a single surgeon (WTH). Elliptical ultrasound setting and prefracture (prechop or preslice) techniques were used in all cases. Cataract nucleus density was graded using lens opacities classification system III and Pentacam Nucleus Staging classification. Clinical measurements included preoperative- and postoperative- corrected visual acuity, preoperative and 2-month postoperative endothelial cell counts, and preoperative and 1-day postoperative central corneal thickness. Intraoperative measurements at the end of the case were phaco time, fluid used, total case time, and Efx energy.ResultsThere were no statistically significant differences between groups regarding age, cataract density, and phaco time (P>0.05). Intraoperatively, we observed significantly less ultrasound energy (P=0.011), case time (P=0.0001), and balanced saline solution (P=0.001) usage in the venturi group. Clinically, both fluidic settings can provide similar clinical outcomes and visual recovery, regarding corrected distance visual acuity, endothelial cell count, and central corneal thickness.ConclusionOur data show that to minimize fluid use, case time, and energy with the prefracture technique, the venturi pump was the most efficient system and was statistically superior to peristaltic pump.
Objective: This study aims evaluating the incidence of risk factors in a population sample, assessed during campaign of prevention of blindness by glaucoma, and analyzing epidemiological data incidence of glaucoma in the city of João Pessoa (PB).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.