We report on the design, development, and performance assessment of a portable time resolved system measuring absorption and scattering spectra of highly diffusive media over the 600-1350 nm range. In view of clinical use, two strategies were implemented; the first one equips the system with high responsivity in key tissue absorbing regions, whereas the second one makes the system immune to time drift. The MEDPHOT protocol was used for the performance assessment of the instrument. Finally, the system was enrolled into its first in vivo trial phase, measuring the broadband absorption and scattering spectra of human manubrium, abdomen fat tissues, and forehead for the in vivo quantification of key tissue constituents.
Diffuse correlation spectroscopy (DCS), combined with time-resolved reflectance spectroscopy (TRS) or frequency domain spectroscopy, aims at path length (i.e. depth) resolved, non-invasive and simultaneous assessment of tissue composition and blood flow. However, while TRS provides a path length resolved data, the standard DCS does not. Recently, a time domain DCS experiment showed path length resolved measurements for improved quantification with respect to classical DCS, but was limited to phantoms and small animal studies. Here, we demonstrate time domain DCS for studies on the adult forehead and the arm. We achieve path length resolved DCS by means of an actively mode-locked Ti:Sapphire laser that allows high coherence pulses, thus enabling adequate signal-to-noise ratio in relatively fast (~1 s) temporal resolution. This work paves the way to the translation of this approach to practical use.
The BabyLux device is a hybrid diffuse optical neuromonitor that has been developed and built to be employed in neonatal intensive care unit for the noninvasive, cot-side monitoring of microvascular cerebral blood flow and blood oxygenation. It integrates time-resolved near-infrared and diffuse correlation spectroscopies in a user-friendly device as a prototype for a future medical grade device. We present a thorough characterization of the device performance using test measurements in laboratory settings. Tests on solid phantoms report an accuracy of optical property estimation of about 10%, which is expected when using the photon diffusion equation as the model. The measurement of the optical and dynamic properties is stable during several hours of measurements within 3% of the average value. In addition, these measurements are repeatable between different days of measurement, showing a maximal variation of 5% in the optical properties and 8% for the particle diffusion coefficient on a liquid phantom. The variability over test/retest evaluation is <3%. The integration of the two modalities is robust and without any cross talk between the two. We also perform in vivo measurements on the adult forearm during arterial cuff occlusion to show that the device can measure a wide range of tissue hemodynamic parameters. We suggest that this platform can form the basis of the next-generation neonatal neuromonitors to be developed for extensive, multicenter clinical testing.
Non-invasive in vivo diffuse optical characterization of human bone opens a new possibility of diagnosing bone related pathologies. We present an in vivo characterization performed on seventeen healthy subjects at six different superficial bone locations: radius distal, radius proximal, ulna distal, ulna proximal, trochanter and calcaneus. A tailored diffuse optical protocol for high penetration depth combined with the rather superficial nature of considered tissues ensured the effective probing of the bone tissue. Measurements were performed using a broadband system for Time-Resolved Diffuse Optical Spectroscopy (TRS) to assess mean absorption and reduced scattering spectra in the 600–1200 nm range and Diffuse Correlation Spectroscopy (DCS) to monitor microvascular blood flow. Significant variations among tissue constituents were found between different locations; with radius distal rich of collagen, suggesting it as a prominent location for bone related measurements, and calcaneus bone having highest blood flow among the body locations being considered. By using TRS and DCS together, we are able to probe the perfusion and oxygen consumption of the tissue without any contrast agents. Therefore, we predict that these methods will be able to evaluate the impairment of the oxygen metabolism of the bone at the point-of-care.
On-chip functional blocks for sample preprocessing are necessary elements for the implementation of fully portable micrototal analysis systems (μTAS). We demonstrate and characterize the microparticle and whole-blood manipulation capabilities of surface acoustic wave (SAW) driven counterflow micropumps. The motion of suspended cells in this system is governed by the two dominant acoustic forces associated with the scattered SAW (of wavelength λf): acoustic-radiation force and acoustic-streaming Stokesian drag force. We show that by reducing the microchannel height (h) beyond a threshold value the balance of these forces is shifted toward the acoustic-radiation force and that this yields control of two different regimes of microparticle dynamics. In the regime dominated by the acoustic radiation force (h ≲ λf), microparticles are collected in the seminodes of the partial standing sound-wave arising from reflections off microchannel walls. This enables the complete separation of plasma and corpuscular components of whole blood in periodical predetermined positions without any prior sample dilution. Conversely, in the regime dominated by acoustic streaming (h ≫ λf), the microbeads follow vortical streamlines in a pattern characterized by three different phases during microchannel filling. This makes it possible to generate a cell-concentration gradient within whole-blood samples, a behavior not previously reported in any acoustic-streaming device. By careful device design, a new class of SAW pumping devices is presented that allows the manipulation and pretreatment of whole-blood samples for portable and integrable biological chips and is compatible with hand-held battery-operated devices.
We report a broadband time-resolved characterization of selected bony prominence locations of the human body. A clinical study was performed at six different bony prominence locations of 53 subjects. A portable broadband timeresolved system equipped with pulse drift and distortion compensation strategy was used for absorption and scattering measurements. Key tissue constituents were quantified as a pilot step towards non-invasive optical assessment of bone pathologies.
Abstract:We present the recipe and characterization for preparing liquid phantoms that are suitable for both near-infrared spectroscopy and diffuse correlation spectroscopy. The phantoms have well-defined and tunable optical and dynamic properties, and consist of a solution of water and glycerol with fat emulsion as the scattering element. The recipe takes into account the effect of bulk refractive index changes due to the addition of glycerol, which is commonly used to alter the sample viscosity. M. Carrol, F. J. Combs, T. Strömberg, A.G. Yodth, and B. Tromberg, "Mapping breast cancer blood flow index, composition, and metabolism in a human subject using combined diffuse optical spectroscopic imaging and diffuse correlation spectroscopy," J. Biomed. Opt. 22(4), 045003 (2017) 21.
Thyroid plays an important role in the endocrine system of the human body. Its characterization by diffuse optics can open new path ways in the non-invasive diagnosis of thyroid pathologies. Yet, the absorption spectra of tyrosine and thyroglobulin–key tissue constituents specific to the thyroid organ–in the visible to near infrared range are not fully available. Here, we present the optical characterization of tyrosine (powder), thyroglobulin (granular form) and iodine (aqueous solution) using a time domain broadband diffuse optical spectrometer in the 550–1350 nm range. Various systematic errors caused by physics of photo migration and sample inherent properties were effectively suppressed by means of advanced time domain diffuse optical methods. A brief comparison with various other known tissue constituents is presented, which reveals key spectral regions for the quantification of the thyroid absorbers in an in vivo scenario.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.