Objectives To compare the image quality and diagnostic performance of conventional motion-corrected periodically rotated overlapping parallel line with enhanced reconstruction (PROPELLER) MRI sequences with post-processed PROPELLER MRI sequences using deep learning-based (DL) reconstructions. Methods In this prospective study of 30 patients, conventional (19 min 18 s) and accelerated MRI sequences (7 min 16 s) using the PROPELLER technique were acquired. Accelerated sequences were post-processed using DL. The image quality and diagnostic confidence were qualitatively assessed by 2 readers using a 5-point Likert scale. Analysis of the pathological findings of cartilage, rotator cuff tendons and muscles, glenoid labrum and subacromial bursa was performed. Inter-reader agreement was calculated using Cohen’s kappa statistic. Quantitative evaluation of image quality was measured using the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Results Mean image quality and diagnostic confidence in evaluation of all shoulder structures were higher in DL sequences (p value = 0.01). Inter-reader agreement ranged between kappa values of 0.155 (assessment of the bursa) and 0.947 (assessment of the rotator cuff muscles). In 17 cases, thickening of the subacromial bursa of more than 2 mm was only visible in DL sequences. The pathologies of the other structures could be properly evaluated by conventional and DL sequences. Mean SNR (p value = 0.01) and CNR (p value = 0.02) were significantly higher for DL sequences. Conclusions The accelerated PROPELLER sequences with DL post-processing showed superior image quality and higher diagnostic confidence compared to the conventional PROPELLER sequences. Subacromial bursa can be thoroughly assessed in DL sequences, while the other structures of the shoulder joint can be assessed in conventional and DL sequences with a good agreement between sequences. Key Points • MRI of the shoulder requires long scan times and can be hampered by motion artifacts. • Deep learning–based convolutional neural networks are used to reduce image noise and scan time while maintaining optimal image quality. The radial k-space acquisition technique (PROPELLER) can reduce the scan time and has potential to reduce motion artifacts. • DL sequences show a higher diagnostic confidence than conventional sequences and therefore are preferred for assessment of the subacromial bursa, while conventional and DL sequences show comparable performance in the evaluation of the shoulder joint.
• CT helps to assess patients with coronary artery disease (CAD). • MRI is the reference standard for evaluation of left ventricular function. • CT provides accurate assessment of global left ventricular function.
ObjectiveTo evaluate iliopsoas atrophy and loss of function after displaced lesser trochanter fracture of the hip.DesignCohort study.SettingDistrict hospital.PatientsTwenty consecutive patients with pertrochanteric fracture and displacement of the lesser trochanter of > 20 mm.InterventionFracture fixation with either an intramedullary nail or a plate.Outcome measurementsClinical scores (Harris hip, WOMAC), hip flexion strength measurements, and magnetic resonance imaging findings.ResultsCompared with the contralateral non-operated side, the affected side showed no difference in hip flexion force in the supine upright neutral position and at 30° of flexion (205.4 N vs 221.7 N and 178.9 N vs. 192.1 N at 0° and 30° flexion, respectively). However, the affected side showed a significantly greater degree of fatty infiltration compared with the contralateral side (global fatty degeneration index 1.085 vs 0.784), predominantly within the psoas and iliacus muscles.ConclusionSevere displacement of the lesser trochanter (> 20 mm) in pertrochanteric fractures did not reduce hip flexion strength compared with the contralateral side. Displacement of the lesser trochanter in such cases can lead to fatty infiltration of the iliopsoas muscle unit. The amount of displacement of the lesser trochanter did not affect the degree of fatty infiltration.Level of evidenceII.
The uterus, which plays an important role in the reproductive process, provides a home for the developing fetus and so must be in a stable, though flexible, location. Various structures with suspensory ligaments help provide this berth. MRI with high spatial resolution allows us to detect and evaluate these relatively fine structures. Under physiologic conditions, MRI can be used to depict uterine and ovarian ligaments (ie, the uterosacral, cardinal, and round ligaments, as well as the suspensory ligament of the ovary). In the presence of pathologic conditions (inflammation, endometriosis, tumors), the suspensory ligaments may appear thickened or invaded, which makes their delineation easier. Understanding the normal anatomy of the suspensory ligaments of the female genital organs and using a standardized nomenclature are essential for identifying and reporting related pathologic conditions. The female pelvic anatomy and the suspensory ligaments of the female genital organs are described as depicted with MRI. Also, the compartmental anatomy of the female pelvis is explained, including the extraperitoneal pelvic spaces. Finally, a checklist is provided for structured reporting of the MRI findings in the female pelvis.
Background Whole spine localizers (WS-loc) of magnetic resonance imaging (MRI) are performed for enumeration of the vertebrae but they can be also used for the evaluation of the spine. Purpose To assess the accuracy of fracture detection using WS-locs of MRI and compare the findings with standard high-resolution short tau inversion recovery (STIR) sequences, and to determine whether the review of WS-locs is useful and if additional information can be gained by assessing the thoracic spine section of the WS-locs. Material and Methods A total of 298 magnetic resonance (MR) examinations of the lumbar spine with WS-locs were evaluated. Two independent readers reviewed the images. In case of fracture detection, further characterization of the fracture was performed. To assess inter-reader agreement, unweighted Cohen's kappa with 95% confidence intervals (CI) and Phi coefficients were calculated. Results The study sample included 187 female and 111 male patients (age range = 65-94 years; median age = 75.0 years). The WS-locs detected 42 fractures of the lumbar spine and 36 of the thoracic spine. Inter-reader agreement for fracture detection in the lumbar and thoracic spine was strong (K = 0.87, 95% CI = 0.78-0.95, Phi = 0.87, and K = 0.88, 95% CI = 0.79-0.96, Phi = 0.88, respectively). Conclusion WS-locs from MR examinations of the lumbar spine provide a good diagnostic tool for the detection and evaluation of unsuspected vertebral fractures. WS-locs show strong inter-reader agreement for fracture detection in the thoracic and lumbar spine.
To compare the diagnostic performance of texture analysis (TA) against visual qualitative assessment in the differentiation of spondyloarthritis (SpA) from degenerative changes in the sacroiliac joints (SIJ). Method: Ninety patients referred for suspected inflammatory lower back pain from the rheumatology department were retrospectively included at our university hospital institution. MRI at 3 T of the lumbar spine and SIJ was performed with oblique coronal T1-weighted (w), fluid-sensitive fat-saturated (fs) TIRM and fsT1w intravenously contrast-enhanced (CE) images. Subjects were divided into three age-and gender-matched groups (30 each) based on definite clinical diagnosis serving as clinical reference standard with either degenerative, inflammatory (SpA) or no changes of the SIJ. SIJ were rated qualitatively by two independent radiologists and quantitatively by region-of-interest-based TA with 304 features subjected to machine learning logistic regression with randomized ten-fold selection of training and validation data. Qualitative and quantitative results were evaluated for diagnostic performance and compared against clinical reference standard. Results: Agreement of radiologist's diagnose with clinical reference was fair for both readers (κ = 0.32 and 0.44). ROC statistics revealed significant outperformance of TA compared to qualitative ratings for differentiation of SpA from remainder (AUC = 0.89 vs. 0.75), SpA from degenerative (AUC = 0.91 vs. 0.67) and TIRM-positive SpA (i.e. with bone marrow edema) from remainder cases (AUC = 0.95 vs. 0.76). T1w-CE images were the most important discriminator for detection of SpA. Conclusions: TA is superior to qualitative assessment for the differentiation of inflammatory from degenerative changes of the SIJ. Intravenous CE-images increase diagnostic yield in quantitative TA.
Objectives: To assess diagnostic performance of standard radial k-space (PROPELLER) MRI sequences and compare with accelerated acquisitions combined with a deep learning-based convolutional neural network (DL-CNN) reconstruction for evaluation of the knee joint. Methods: Thirty-five patients undergoing MR imaging of the knee at 1.5 T were prospectively included. Two readers evaluated image quality and diagnostic confidence of standard and DL-CNN accelerated PROPELLER MR sequences using a four-point Likert scale. Pathological findings of bone, cartilage, cruciate and collateral ligaments, menisci, and joint space were analyzed. Inter-reader agreement (IRA) for image quality and diagnostic confidence was assessed using intraclass coefficients (ICC). Cohen’s Kappa method was used for evaluation of IRA and consensus between sequences in assessing different structures. In addition, image quality was quantitatively evaluated by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Results: Mean acquisition time of standard vs. DL-CNN sequences was 10 min 3 s vs. 4 min 45 s. DL-CNN sequences showed significantly superior image quality and diagnostic confidence compared to standard MR sequences. There was moderate and good IRA for assessment of image quality in standard and DL-CNN sequences with ICC of 0.524 and 0.830, respectively. Pathological findings of the knee joint could be equally well detected in both sequences (κ-value of 0.8). Retropatellar cartilage could be significantly better assessed on DL-CNN sequences. SNR and CNR was significantly higher for DL-CNN sequences (both p < 0.05). Conclusions: In MR imaging of the knee, DL-CNN sequences showed significantly higher image quality and diagnostic confidence compared to standard PROPELLER sequences, while reducing acquisition time substantially. Both sequences perform comparably in the detection of knee-joint pathologies, while DL-CNN sequences are superior for evaluation of retropatellar cartilage lesions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.