Mobile gait analysis systems based on inertial sensing on the shoe are applied in a wide range of applications. Especially for medical applications, they can give new insights into motor impairment in, e.g., neurodegenerative disease and help objectify patient assessment. One key component in these systems is the reconstruction of the foot trajectories from inertial data. In literature, various methods for this task have been proposed. However, performance is evaluated on a variety of datasets due to the lack of large, generally accepted benchmark datasets. This hinders a fair comparison of methods. In this work, we implement three orientation estimation and three double integration schemes for use in a foot trajectory estimation pipeline. All methods are drawn from literature and evaluated against a marker-based motion capture reference. We provide a fair comparison on the same dataset consisting of 735 strides from 16 healthy subjects. As a result, the implemented methods are ranked and we identify the most suitable processing pipeline for foot trajectory estimation in the context of mobile gait analysis.
Background and objectives:Hereditary spastic paraplegia (HSP) causes progressive spasticity and weakness of the lower limbs. As neurological examination and the clinical Spastic Paraplegia Rating Scale (SPRS) are subject to potential patient- and clinician-dependent bias, instrumented gait analysis bears the potential to objectively quantify impaired gait. The aim of the present study was to investigate gait cyclicity parameters by application of a mobile gait analysis system in a cross sectional cohort of HSP patients and a longitudinal fast progressing subcohort.Methods:Using wearable sensors attached to the shoes, HSP patients and controls performed a 4x10 meters walking test during regular visits in three outpatient centers. Patients were also rated according to the SPRS and in a subset, questionnaires on quality of life and fear of falling were obtained. An unsupervised segmentation algorithm was employed to extract stride parameters and respective coefficients of variation.Results:Mobile gait analysis was performed in a total of 112 ambulatory HSP patients and 112 age and gender matched controls. While swing time was unchanged compared to controls, there were significant increases in the duration of the total stride phase and the duration of the stance phase, both regarding absolute values and coefficients of variation values. While stride parameters did not correlate to age, weight or height of the patients, there were significant associations of absolute stride parameters to single SPRS items reflecting impaired mobility (|r| > 0.50), to patients’ quality of life (|r| > 0.44), and notably to disease duration (|r| > 0.27). Sensor-derived coefficients of variation, on the other hand, were associated with patient-reported fear of falling (|r| > 0.41) and cognitive impairment (|r| > 0.40). In a small 1-year follow-up analysis of patients with complicated HSP and fast progression, absolute values of mobile gait parameters had significantly worsened compared to baseline.Discussion:The presented wearable sensor system provides parameters of stride characteristics which appear clinically valid to reflect gait impairment in HSP. Due to the feasibility with regard to time, space and costs, the present study forms the basis for larger scale longitudinal and interventional studies in HSP.
Activities of a clinical staff in healthcare environments must regularly be adapted to new treatment methods, medications, and technologies. This constant evolution requires the monitoring of the workflow, or the sequence of actions from actors involved in a procedure, to ensure quality of medical services. In this context, recent advances in sensing technologies, including Real-time Location Systems and Computer Vision, enable high-precision tracking of actors and equipment. The current state-of-the-art about healthcare workflow monitoring typically focuses on a single technology and does not discuss its integration with others. Such an integration can lead to better solutions to evaluate medical workflows. This study aims to fill the gap regarding the analysis of monitoring technologies with a systematic literature review about sensors for capturing the workflow of healthcare environments. Its main scientific contribution is to identify both current technologies used to track activities in a clinical environment and gaps on their combination to achieve better results. It also proposes a taxonomy to classify work regarding sensing technologies and methods. The literature review does not present proposals that combine data obtained from Real-time Location Systems and Computer Vision sensors. Further analysis shows that a multimodal analysis is more flexible and could yield better results.
Developing machine learning algorithms for time-series data often requires manual annotation of the data. To do so, graphical user interfaces (GUIs) are an important component. Existing Python packages for annotation and analysis of time-series data have been developed without addressing adaptability, usability, and user experience. Therefore, we developed a generic open-source Python package focusing on adaptability, usability, and user experience. The developed package, Machine Learning and Data Analytics (MaD) GUI, enables developers to rapidly create a GUI for their specific use case. Furthermore, MaD GUI enables domain experts without programming knowledge to annotate time-series data and apply algorithms to it. We conducted a small-scale study with participants from three international universities to test the adaptability of MaD GUI by developers and to test the user interface by clinicians as representatives of domain experts. MaD GUI saves up to 75% of time in contrast to using a state-of-the-art package. In line with this, subjective ratings regarding usability and user experience show that MaD GUI is preferred over a state-of-the-art package by developers and clinicians. MaD GUI reduces the effort of developers in creating GUIs for time-series analysis and offers similar usability and user experience for clinicians as a state-of-the-art package.
Progressive spasticity and gait impairment is the functional hallmark of hereditary spastic paraplegia (HSP), but due to inter‐individual variability, longitudinal studies on its progression are scarce. We investigated the progression of gait deficits via mobile digital measurements in conjunction with clinical and patient‐reported outcome parameters. Our cohort included adult HSP patients (n = 55) with up to 77 months of follow‐up. Gait speed showed a significant association with SPRS progression. Changes in stride time and gait variability correlated to fear of falling and quality of life, providing evidence that gait parameters are meaningful measures of HSP progression.
The world of healthcare constantly aims to improve the lives of people while nurturing their health and comfort. Digital health and wearable technologies are aimed at making this possible. However, there are numerous factors that need to be addressed such as aging, disabilities, and health hazards. These factors are intensified in palliative care (PC) patients and limited hospital capacities make it challenging for health care providers (HCP) to handle the crisis. One of the most common symptoms reported by PC patients with severe conditions is dyspnoea. Monitoring devices with sufficient comfort could improve symptom control of patients with dyspnoea in PC. In this article, we discuss the proof-of-concept study to investigate a smart patch (SP), which monitors the pulmonary parameters: (a) breathing rate (BR) and inspiration to expiration ratio (I:E); markers for distress: (b) heart rate (HR) and heart rate variability (HRV), and (c) transmits real-time data securely to an adaptable user interface, primarily geared for palliative HCP but scalable to specific needs. The concept is verified by measuring and analyzing physiological signals from different electrode positions on the chest and comparing the results achieved with the gold standard Task Force Monitor (TFM).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.