Gamma probes have been used for sentinel lymph node biopsy in melanoma and breast cancer. However, these probes can provide only radioactivity counts and variable pitch audio output based on the intensity of the detected radioactivity. We have developed a small semiconductor gamma camera (SSGC) that allows visualisation of the size, shape and location of the target tissues. This study is designed to characterise the performance of the SSGC for radioguided surgery of metastatic lesions and for other imaging applications amenable to the smaller format of this prototype imaging system. The detector head had 32 cadmium telluride semiconductor arrays with a total of 1,024 pixels, and with application-specific integrated circuits (ASICs) and a tungsten collimator. The entire assembly was encased in a lead housing measuring 152 mmx166 mmx65 mm. The effective visual field was 44.8 mmx44.8 mm. The energy resolution and imaging aspects were tested. Two spherical 5-mm- and 15-mm-diameter technetium-99m radioactive sources that had activities of 0.15 MBq and 100 MBq, respectively, were used to simulate a sentinel lymph node and an injection site. The relative detectability of these foci by the new detector and a conventional scintillation camera was studied. The prototype was also examined in a variety of clinical applications. Energy resolution [full-width at half-maximum (FWHM)] for a single element at the centre of the field of view was 4.2% at 140 keV (99mTc), and the mean energy resolution of the CdTe detector arrays was approximately 7.8%. The spatial resolution, represented by FWHM, had a mean value of 1.56 +/- 0.05 mm. Simulated node foci could be visualised clearly by the SSGC using a 15-s acquisition time. In preliminary clinical tests, the SSGC successfully imaged diseases in a variety of tissues, including salivary and thyroid glands, temporomandibular joints and sentinel lymph nodes. The SSGC has significant potential for diagnosing diseases and facilitating subsequent radioguided surgery.
We sought to develop dual-modality imaging probes using functionalized silica nanoparticles to target human epidermal growth factor receptor 2 (HER2)-overexpressing breast cancer cells and achieve efficient target imaging of HER2-expressing tumors. Polyamidoamine-based functionalized silica nanoparticles (PCSNs) for multimodal imaging were synthesized with near-infrared (NIR) fluorescence (indocyanine green (ICG)) and technetium-99m (99mTc) radioactivity. Anti-HER2 antibodies were bound to the labeled PCSNs. These dual-imaging probes were tested to image HER2-overexpressing breast carcinoma cells. In vivo imaging was also examined in breast tumor xenograft models in mice. SK-BR3 (HER2 positive) cells were imaged with stronger NIR fluorescent signals than that in MDA-MB231 (HER2 negative) cells. The increased radioactivity of the SK-BR3 cells was also confirmed by phosphor imaging. NIR images showed strong fluorescent signals in the SK-BR3 tumor model compared to muscle tissues and the MDA-MB231 tumor model. Automatic well counting results showed increased radioactivity in the SK-BR3 xenograft tumors. We developed functionalized silica nanoparticles loaded with 99mTc and ICG for the targeting and imaging of HER2-expressing cells. The dual-imaging probes efficiently imaged HER2-overexpressing cells. Although further studies are needed to produce efficient isotope labeling, the results suggest that the multifunctional silica nanoparticles are a promising vehicle for imaging specific components of the cell membrane in a dual-modality manner.
Osteogenic potential of biomaterials used in bone regenerative therapy has been mainly examined in an animal-implantation study. We have here evaluated the applicability of bone scintigraphy in imaging ectopic bone formation, especially its initial phase, by β-tricalcium phosphate (β-TCP) particles that were implanted in rat dorsal subcutaneous tissues. In implanted osteogenic osteosarcoma cells used as a positive control, osteoid formation was found by histological examination and bone scintigraphy using 99mTc- hydroxymethyl diphosphonate (HMDP) at 2 and 3 weeks post-implantation, respectively, while the microfocuscomputed tomography (μCT) system required further mineralization, which occurred at 4 weeks. Implantation of β-TCP particles alone induced only faint biomineralization inside the particles, which could be microscopically detected by calcein chelation at 2 weeks post-implantation, but not by other histological examinations (e.g., HE staining) or μCT. However, the bone scintigraphy successfully detected this microscopic change at 1 week. Implanted hydroxyapatite (HAp) particles alone used as a negative control did not induce mineralization at microscopic levels, and therefore nothing was detected by either calcein chelation or bone scintigraphy. In conclusion, the bone scintigraphic methodology, although exhibiting less quantitation and resolution, would be applicable as a non-invasive, highly sensitive methodology in detecting the initial, microscopic changes associated with mineralization.
BackgroundWe propose a new approach to facilitate sentinel node biopsy examination by multimodality imaging in which radioactive and near-infrared (NIR) fluorescent nanoparticles depict deeply situated sentinel nodes and fluorescent nodes with anatomical resolution in the surgical field. For this purpose, we developed polyamidoamine (PAMAM)-coated silica nanoparticles loaded with technetium-99m (99mTc) and indocyanine green (ICG).MethodsWe conducted animal studies to test the feasibility and utility of this dual-modality imaging probe. The mean diameter of the PAMAM-coated silica nanoparticles was 30 to 50 nm, as evaluated from the images of transmission electron microscopy and scanning electron microscopy. The combined labeling with 99mTc and ICG was verified by thin-layer chromatography before each experiment. A volume of 0.1 ml of the nanoparticle solution (7.4 MBq, except for one rat that was injected with 3.7 MBq, and 1 μg of an ICG derivative [ICG-sulfo-OSu]) was injected submucosally into the tongue of six male Wistar rats.ResultsScintigraphic images showed increased accumulation of 99mTc in the neck of four of the six rats. Nineteen lymph nodes were identified in the dissected neck of the six rats, and a contact radiographic study showed three nodes with a marked increase in uptake and three nodes with a weak uptake. NIR fluorescence imaging provided real-time clear fluorescent images of the lymph nodes in the neck with anatomical resolution. Six lymph nodes showed weak (+) to strong (+++) fluorescence, whereas other lymph nodes showed no fluorescence. Nodes showing increased radioactivity coincided with the fluorescent nodes. The radioactivity of 15 excised lymph nodes from the four rats was assayed using a gamma well counter. Comparisons of the levels of radioactivity revealed a large difference between the high-fluorescence-intensity group (four lymph nodes; mean, 0.109% ± 0.067%) and the low- or no-fluorescence-intensity group (11 lymph nodes; mean, 0.001% ± 0.000%, p < 0.05). Transmission electron microscopy revealed that small black granules were localized to and dispersed within the cytoplasm of macrophages in the lymph nodes.ConclusionAlthough further studies are needed to determine the appropriate dose of the dual-imaging nanoparticle probe for effective sensitivity and safety, the results of this animal study revealed a novel method for improved node detection by a dual-modality approach for sentinel lymph node biopsy.
Many measures have been developed to determine the extent of disc displacement in internal derangements of the temporomandibular joint (TMJ) using magnetic resonance imaging. The purpose of this study was to develop a quantitative method of analyzing disc position and to evaluate the positions of the disc in internal derangements of the TMJ (group 1, with reduction; group 2, without reduction). Magnetic resonance images of 150 TMJs in 20 healthy volunteers and 55 patients with internal derangements were evaluated. The anatomical points of interest of the TMJ, including the anterior (DA) and posterior (DP) points of the disc, were marked on parasagittal magnetic resonance images of the TMJ disc taken in both the closed- and the open-mouth positions. All points were recorded using an x-y coordinate system, with reference to a referral line. In the closed-mouth position, the DP in patients in group 1 was situated in a more-anterior direction than the DP in volunteers. The DP in group 2 was located further anterior and inferior than the DP in group 1. However, the position of the DA did not differ between group 1 and group 2. In the open-mouth position, the DP was displaced anteroinferiorly to a greater extent in group 2 than in group 1 (one-way ANOVA, followed by Scheffe's test; P < 0.0001). The distance between the disc points in the closed- and open-mouth positions was also evaluated. Comparison of the disc point position in the closed- and open-mouth positions in symptomatic and asymptomatic displaced TMJ discs revealed no significant difference. In conclusion, most of our results quantitatively support previously reported findings in imaging, surgical, and histopathological studies of TMJ internal derangement. We suggest that our measure of disc position of the TMJ would be useful to assess the status and response to treatment of internal derangements of the TMJ.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.