Titanium alloys are still on the top list of fundamental materials intended for dental, orthopedics, neurological, and cardiovascular implantations. Recently, a special attention has been paid to vanadium-free titanium alloy, Ti6Al7Nb, that seems to represent higher biocompatibility than traditional Ti6Al4V alloy. Surprisingly, these data are not thoroughly elaborated in the literature; particularly there is a lack of comparative experiments conducted simultaneously and at the same conditions. Our study fills these shortcomings in the field of blood contact and microbiological colonization. To observe platelets adhesion and biofilm formation on the surfaces of compared titanium alloys, fluorescence microscope Olympus GX71 and scanning electron microscope HITACHI S-3000N were used. Additionally, flow cytometry analysis of platelets aggregation and activation in the whole blood after contact with sample surface, as an essential tool for biomaterial thrombocompatibility assessment, was proposed. As a result of our study it was demonstrated that polished surfaces of Ti6Al7Nb and Ti6Al4V alloys after contact with whole citrated blood and E. coli bacterial cells exhibit a considerable difference. Overall, it was established that Ti6Al4V has distinct tendency to higher thrombogenicity, more excessive bacterial biofilm formation and notable cytotoxic properties in comparison to Ti6Al7Nb. However, we suggest these studies should be extended for other types of cells and biological objects.
Most biomaterials at present have sufficient mechanical properties; however compliance with standards for biocompatibility is often not sufficient in clinical practice. This may be due to the complexity of biological systems in general and the diversity of individual responses to these materials by implant recipients. Significant improvement of biocompatibility must involve surface modification of implants, which in the future will make it possible to introduce individually selected types of surface modification for individual recipients. The key to this technology seems to be understanding the processes occurring at the site of contact of the implant with the tissue. Processes resulting from the stress generated by the contact of the biomaterial surfaces were observed with endothelial cells line EA.hy926, and it was demonstrated that differently modified surfaces of medical steel (polished medical steel and medical steel coated with Parylene C and nanocrystalline diamond) cause diverse cellular response in cells grown on these surfaces, on both the cellular (cell morphology and cell survival) and molecular (transcriptome and proteome profiles) levels. The herein presented observations are a good starting point not only for further research and the development of far-reaching personalization of medical implants, but also to study the potential use of cells as a specific sensor capable of recognizing different surfaces with which these cells come into contact. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 880-893, 2016.
The aim of present study was to determine the hemocompatibility, cellular response of endothelial cells and bacterial adhesion to a new polyester nanocomposite. The carbon nanoparticle nanocomposite was prepared via in situ polymerization of monomers to obtain material of hardness 55 Sh D similar to polyurethanes used in medical applications, for example, in heart-assisting devices. The carbon nanoparticle-containing polyester exhibits markedly reduced bacterial colonization, as compared to commercially available polyurethanes. Further the nanocomposite possesses markedly improved hemocompatibility, as determined by flow cytometry, and robust endothelialization. Possible explanations for these beneficial properties include surface nanoroughness of carbon nanoparticle-containing nanocomposites and presence of fatty acid sequences within polymer structure.
Three medically used alloys (Ti6Al4V, Ti6Al7Nb, and AISI 316 L) are compared due to proliferative potential and metabolic response of human cells (osteoblasts line Saos-2 and endothelial cells line EA.hy-926) seeded on the surfaces of these alloys. Although no statistically significant difference in the proliferative potential of the cells cultured on the surfaces of examined biomaterials was observed, it does not exclude relevant differences in metabolic response of these cells assessed as changes in genes' expression. As a result of our studies it was demonstrated that the changes in the expression of examined genes were very common. Our observation suggests the presence of the process of selective recognition of the contacted biomaterials by the cells seeded on their surfaces. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1607-1617, 2017.
Biological acceptance is one of the most important aspects of a biomaterial and forms the basis for its clinical use. The aim of this study was a comprehensive biological evaluation (cytotoxicity test, bacterial colonization test, blood platelets adhesion test and transcriptome and proteome analysis of Saos-2 cells after contact with surface of the biomaterial) of biomaterials used in spinal and orthopedic surgery, namely, Ti6Al4V ELI (Extra Low Interstitials), its modified version obtained as a result of melting by electron beam technology (Ti6Al4V ELI-EBT), polyether ether ketone (PEEK) and polished medical steel American Iron and Steel Institute (AISI) 316L (the reference material). Biological tests were carried out using the osteoblasts-like cells (Saos-2, ATCC HTB-85) and bacteria Escherichia coli (DH5α). Results showed lack of cytotoxicity of all materials and the surfaces of both Ti6Al4V ELI and PEEK exhibit a significantly higher resistance to colonization with E. coli cells, while the more porous surface of the same titanium alloy produced by electron beam technology (EBT) is more susceptible to microbial colonization than the control surface of polished medical steel. None of the tested materials showed high toxicity in relation to E. coli cells. Susceptibility to platelet adhesion was very high for polished medical steel AISI 316L, whilst much lower for the other biomaterials and can be ranked from the lowest to the highest as follows: PEEK < Ti6Al4V ELI < Ti6Al4V ELI-EBT. The number of expressed genes in Saos-2 cells exposed to contact with the examined biomaterials reached 9463 genes in total (ranging from 8455 genes expressed in cells exposed to ELI to 9160 genes in cells exposed to PEEK). Whereas the number of differentially expressed proteins detected on two-dimensional electrophoresis gels in Saos-2 cells after contact with the examined biomaterials was 141 for PEEK, 223 for Ti6Al4V ELI and 133 for Ti6Al4V ELI-EBT. Finally, 14 proteins with altered expression were identified by mass spectrometry. In conclusion, none of the tested biomaterials showed unsatisfactory levels of cytotoxicity. The gene and protein expression analysis, that represents a completely new approach towards characterization of these biomaterials, showed that the polymer PEEK causes much more intense changes in gene and protein expression and thus influences cell metabolism.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.