BackgroundTo study the reliability and validity of high-resolution peripheral quantitative CT (HR-pQCT) with microCT (μCT) as gold standard in the visual detection of cortical breaks in metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints.MethodsTen cadaveric fingers (10 MCP and 9 PIP joints) were imaged by HR-pQCT and μCT and visually analyzed by two independent readers. Intra- and interreader reliability were evaluated for the presence (yes/no, kappa statistics) and the total number (intraclass correlation coefficient, ICC) of cortical breaks. Sensitivity, specificity, positive and negative predictive value (PPV respectively NPV) of HR-pQCT in detecting cortical breaks were calculated.ResultsWith HR-pQCT, mean 149 cortical breaks were identified and with μCT mean 129 (p < 0.05). Intrareader reliability for the presence of a cortical break per quadrant was 0.52 (95 % CI 0.48–0.56) and 0.71 (95 % CI 0.67–0.75) for HR-pQCT and μCT, respectively, and for the total number of cortical breaks 0.61 (95 % CI 0.49–0.70) and 0.75 (95 % CI 0.68–0.82). Interreader reliability for the presence of a cortical break per quadrant was 0.37 (95 % CI 0.33–0.41) and 0.45 (95 % CI 0.41–0.49) for HR-pQCT and μCT, respectively, and for the number of cortical breaks 0.55 (95 % CI 0.43–0.65) and 0.54 (95 % CI 0.35–0.67). Sensitivity, specificity, PPV and NPV of HR-pQCT were 81.6, 64.0, 81.6, and 64 % respectively.ConclusionCortical breaks were commonly visualized in MCP and PIP joints with HR-pQCT and μCT. Reliability of both HR-pQCT and μCT was fair to moderate. HR-pQCT was highly sensitive to detect cortical breaks with μCT as gold standard.Electronic supplementary materialThe online version of this article (doi:10.1186/s12891-016-1148-y) contains supplementary material, which is available to authorized users.
Small cortical interruptions may be the first sign of an erosion, and more interruptions can be found in patients with rheumatoid arthritis (RA) compared with healthy subjects. First, we compared the number and size of interruptions in patients with RA with healthy subjects using high-resolution peripheral quantitative CT (HR-pQCT). Second, we investigated the association between structural damage and inflammatory markers on conventional radiography (CR) and MRI with interruptions on HR-pQCT. Third, the added value of HR-pQCT over CR and MRI was investigated. The finger joints of 39 patients with RA and 38 healthy subjects were examined through CR, MRI, and HR-pQCT. CRs were scored using the Sharp/Van der Heijde method. MRI images were analyzed for the presence of erosions, bone marrow edema, and synovitis. HR-pQCT images were analyzed for the number, surface area, and volume of interruptions using a semiautomated algorithm. Descriptives were calculated and associations were tested using generalized estimating equations. Significantly more interruptions and both a larger surface area and the volume of interruptions were detected in the metacarpophalangeal joints of patients with RA compared with healthy subjects (median, 2.0, 1.42 mm , and 0.48 mm versus 1.0, 0.69 mm , and 0.23 mm , respectively; all p < 0.01). Findings on CR and MRI were significantly associated with more and larger interruptions on HR-pQCT (prevalence ratios [PRs] ranging from 1.03 to 7.74; all p < 0.01) in all subjects, and were consistent in patients with RA alone. Having RA was significantly associated with more and larger interruptions on HR-pQCT (PRs, 2.33 to 5.39; all p < 0.01), also after adjustment for findings on CR or MRI. More and larger cortical interruptions were found in the finger joints of patients with RA versus healthy subjects, also after adjustment for findings on CR or MRI, implying that HR-pQCT imaging may be of value in addition to CR and MRI for the evaluation of structural damage in patients with RA. © 2018 The Authors. Journal of Bone and Mineral Research Published by Wiley Periodicals Inc.
Objectives The purpose of the study was to prospectively investigate change (repair or progression) in the number, surface area and volume of cortical interruptions, bone density (vBMD) and micro-structural parameters assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT) in finger joints of patients with rheumatoid arthritis (RA) treated with synthetic disease modifying anti-rheumatic drugs (sDMARDs) and/or biologic DMARDs (bDMARDs) over a 1-year follow-up period, and in comparison with healthy subjects (HS). Methods Thirty-two patients with RA (221 joints, 53% on bDMARDs) and 32 HS (117 joints) were assessed at baseline and after 1 year using semi-automatic analysis of HR-pQCT images. Mean changes (group level) and the proportion of joints (joint level) with changes beyond the least significant change were calculated. Results At baseline, 530 interruptions were identified in patients, and 136 in HS. The mean of the interruption parameters did not significantly change in either group Mean vBMD decreased more in patients than in HS (− 4.4 versus − 1.1 mgHA/ cm 3 , respectively). In patients versus HS, proportionally more joints showed repair in interruption volume (6.6% versus 1.7%, respectively) and loss of vBMD (26.7% versus 12.9%, respectively). In patients on sDMARDs versus patients on bDMARDs, proportionally more joints showed progression in the number of interruptions and loss of vBMD (6.1% versus 1.8% and 31.3% versus 17.2%, respectively). Conclusions HR-pQCT is able to quantify bone repair and progression. Cortical interruption-, vBMD-, and micro-structure were impaired in RA, of which vBMD and micro-structure further deteriorated, particularly in patients on sDMARDs.
ObjectivesTo introduce a fully-automated algorithm for the detection of small cortical interruptions (≥0.246mm in diameter) on high resolution peripheral quantitative computed tomography (HR-pQCT) images, and to investigate the additional value of manual correction of the automatically obtained contours (semi-automated procedure).MethodsTen metacarpophalangeal joints from seven patients with rheumatoid arthritis (RA) and three healthy controls were imaged with HR-pQCT. The images were evaluated by an algorithm according to the fully- and semi-automated procedure for the number and surface of interruptions per joint. Reliability between the fully- and semi-automated procedure and between two independent operators was tested using intra-class correlation coefficient (ICC) and the proportion of matching interruptions. Validity of single interruptions detected was tested by comparing it to visual scoring, as gold standard. The positive predictive value (PPV) and sensitivity were calculated.ResultsThe median number of interruptions per joint was 14 (range 2 to 59) and did not significantly differ between the fully- and semi-automated procedure (p = 0.37). The median interruption surface per joint was significantly higher with the fully- vs. semi-automated procedure (respectively, 8.6mm2 vs. 5.8mm2 and 6.1mm2, p = 0.01). Reliability was almost perfect between the fully- and semi-automated procedure for both the number and surface of interruptions (ICC≥0.95) and the proportion of matching interruptions was high (≥76%). Also the inter-operator reliability was almost perfect (ICC≥0.97, proportion of matching interruptions 92%). The PPV ranged from 27.6% to 29.9%, and sensitivity from 69.7% to 76.3%. Most interruptions detected with the algorithm, did show an interruption on a 2D grayscale image. However, this interruption did not meet the criteria of an interruption with visual scoring.ConclusionThe algorithm for HR-pQCT images detects cortical interruptions, and its interruption surface. Reliability and validity was comparable for the fully- and semi-automated procedures. However, we advise the use of the semi-automated procedure to assure quality. The algorithm is a promising tool for a sensitive and objective assessment of cortical interruptions in finger joints assessed by HR-pQCT.
Background: Joint space assessment for rheumatoid arthritis (RA) by ordinal conventional radiographic scales is susceptible to floor and ceiling effects. High-resolution peripheral quantitative computed tomography (HR-pQCT) provides superior resolution, and may detect earlier changes. The goal of this work was to compare existing 3D methods to calculate joint space width (JSW) metrics in human metacarpophalangeal (MCP) joints with HR-pQCT and reach consensus for future studies. Using the consensus method, we established reproducibility with repositioning as well as feasibility for use in secondgeneration HR-pQCT scanners.Methods: Three published JSW methods were compared using datasets from individuals with RA from three research centers. A SPECTRA consensus method was developed to take advantage of strengths of the individual methods. Using the SPECTRA method, reproducibility after repositioning was tested and agreement between scanner generations was also established.Results: When comparing existing JSW methods, excellent agreement was shown for JSW minimum and mean (ICC 0.987-0.996) but not maximum and volume (ICC 0.000-0.897). Differences were identified as variations in volume definitions and algorithmic differences that generated high sensitivity to boundary conditions. The SPECTRA consensus method reduced this sensitivity, demonstrating good scan-rescan reliability (ICC >0.911) except for minimum JSW (ICC 0.656). There was strong agreement between results from first-and second-generation HR-pQCT (ICC >0.833). Conclusions:The SPECTRA consensus method combines unique strengths of three independentlydeveloped algorithms and leverages underlying software updates to provide a mature analysis to measure 3D JSW. This method is robust with respect to repositioning and scanner generations, suggesting its suitability
BackgroundWe developed a semi-automated algorithm that detects cortical interruptions in finger joints using high-resolution peripheral quantitative computed tomography (HR-pQCT), and extended it with trabecular void volume measurement. In this study we tested the reproducibility of the algorithm using scan/re-scan data.MethodsSecond and third metacarpophalangeal joints of 21 subjects (mean age 49 (SD 11) years, 17 early rheumatoid arthritis and 4 undifferentiated arthritis, all diagnosed < 1 year ago) were imaged twice by HR-pQCT on the same day with repositioning between scans. The images were analyzed twice by one operator (OP1) and once by an additional operator (OP2), who independently corrected the bone contours when necessary. The number, surface and volume of interruptions per joint were obtained. Intra- and inter-operator reliability and intra-operator reproducibility were determined by intra-class correlation coefficients (ICC). Intra-operator reproducibility errors were determined as the least significant change (LSCSD).ResultsPer joint, the mean number of interruptions was 3.1 (SD 3.6), mean interruption surface 4.2 (SD 7.2) mm2, and mean interruption volume 3.5 (SD 10.6) mm3 for OP1. Intra- and inter-operator reliability was excellent for the cortical interruption parameters (ICC ≥0.91), except good for the inter-operator reliability of the interruption surface (ICC = 0.70). The LSCSD per joint was 4.2 for the number of interruptions, 5.8 mm2 for interruption surface, and 3.2 mm3 for interruption volume.ConclusionsThe algorithm was highly reproducible in the detection of cortical interruptions and their volume. Based on the LSC findings, the potential value of this algorithm for monitoring structural damage in the joints in early arthritis patients needs to be tested in clinical studies.Electronic supplementary materialThe online version of this article (10.1186/s12880-018-0255-7) contains supplementary material, which is available to authorized users.
We developed a semi-automated algorithm for the detection of cortical interruptions in finger joints using high-resolution peripheral quantitative computed tomography (HR-pQCT). Here, we tested its reliability compared to microCT (µCT) as gold standard. Nineteen joints of 10 female anatomic index fingers were imaged by HR-pQCT and µCT (82 and 18 µm isotropic voxel sizes, respectively). The algorithm was applied for detection of cortical interruptions of different minimum diameters (range >0.16 to >0.50 mm). Reliability was tested at the joint level with intra-class correlation coefficient (ICC) for the number of interruptions and interruption surface, and at the level of a single interruption for matching between HR-pQCT and µCT with a fixed interruption diameter (>0.10 mm) on µCT. The positive predictive value (PPV0.10mm) and sensitivity0.10mm were evaluated. The mean number of interruptions per joint depended on the diameter cut-off and ranged from 3.4 to 53.5 on HR-pQCT and from 1.8 to 45.1 on µCT for interruptions >0.50 to >0.16 mm, respectively. Reliability at the joint level was almost perfect (ICC ≥0.81) for both the number and surface of interruptions >0.16 and >0.33 mm. As expected, the PPV0.10mm increased with increasing interruption diameter from 84.9 to 100%, for interruptions >0.16 and >0.50 mm, respectively. However, the sensitivity0.10mm decreased with increasing interruption diameter from 62.4 to 4.7%. This semi-automated algorithm for HR-pQCT in finger joints performed best for the detection of cortical interruptions with a minimum diameter of >0.16 or >0.33 mm, showing almost perfect reliability at the joint level and interruptions matched with those on µCT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.