2017
DOI: 10.1371/journal.pone.0175829
|View full text |Cite|
|
Sign up to set email alerts
|

An automated algorithm for the detection of cortical interruptions on high resolution peripheral quantitative computed tomography images of finger joints

Abstract: ObjectivesTo introduce a fully-automated algorithm for the detection of small cortical interruptions (≥0.246mm in diameter) on high resolution peripheral quantitative computed tomography (HR-pQCT) images, and to investigate the additional value of manual correction of the automatically obtained contours (semi-automated procedure).MethodsTen metacarpophalangeal joints from seven patients with rheumatoid arthritis (RA) and three healthy controls were imaged with HR-pQCT. The images were evaluated by an algorithm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 15 publications
(21 citation statements)
references
References 31 publications
0
21
0
Order By: Relevance
“…Meanwhile, the second‐generation HR‐pQCT (HR‐pQCT2) has been introduced, which has a higher spatial resolution (95 μm versus 130 μm) and smaller voxel size (61 μm versus 82 μm). This higher resolution enables better distinction between bone and nonbone, which may reduce the number of falsely detected interruptions due to the partial volume effect . Additionally, the minimum interruption diameter will be smaller when applying two dilation steps (≥0.305 mm versus ≥0.410 mm, respectively).…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Meanwhile, the second‐generation HR‐pQCT (HR‐pQCT2) has been introduced, which has a higher spatial resolution (95 μm versus 130 μm) and smaller voxel size (61 μm versus 82 μm). This higher resolution enables better distinction between bone and nonbone, which may reduce the number of falsely detected interruptions due to the partial volume effect . Additionally, the minimum interruption diameter will be smaller when applying two dilation steps (≥0.305 mm versus ≥0.410 mm, respectively).…”
Section: Discussionmentioning
confidence: 99%
“…The outer margin of the cortex was identified using an autocontouring algorithm . The contours were visually inspected and, if necessary, adjusted by an operator.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations