IntroductionWe previously showed that erythropoietin (EPO) attenuates the morphological signs of spinal cord ischemia/reperfusion (I/R) injury in swine [1] without, however, improving neurological function. The clinical use of EPO has been cautioned most recently due to serious safety concerns arising from an increased mortality in acute stroke patients treated with EPO and simultaneously receiving systemic thrombolysis [2]. Carbamylated EPO (cEPO) is an EPO derivative without erythropoietic activity and devoid of the EPO side eff ects, but with apparently well maintained cytoprotective qualities [3]. We therefore tested the hypothesis whether cEPO may be equally effi cient as EPO in reducing morphological as well as functional aortic occlusion-induced spinal cord I/R injury. Methods In a randomized and blinded trial pigs received either vehicle (control, n = 9), EPO or cEPO, respectively (n = 9 each; 5,000 IU/kg over 30 minutes before and during the fi rst 4 hours of reperfusion). Animals underwent 30 minutes of thoracic aortic balloon occlusion with catheters placed immediately downstream of the A. subclavia and upstream of the aortic trifurcation. Spinal cord function was assessed by motor evoked potentials (MEP as percentage of the amplitude before aortic occlusion) and lower limb refl exes (assessed as the subjective strength of response) for a period of 10 hours after reperfusion. Tissue damage was evaluated using Nissl staining. Results Both EPO-treated and cEPO-treated animals presented with attenuated spinal cord injury in the Nissl staining (median (quartile) percentage of damaged neurons in the thoracic segments: control 27 (25,44), cEPO 8 (4,10), and EPO 5 (5,7), P <0.001 vs control group; in the lumbar segments: control 26 (19,32), cEPO 7 (5,13), EPO 8 (5,10), P <0.001 vs control group). However, while only cEPO treatment was associated with recovery of the MEP amplitude to pre-occlusion values when compared with the control group (P <0.05), lower limb refl ex response was comparably restored stronger in both treatment groups (P <0.05 vs control). Conclusions In a clinically relevant porcine model mimicking aortic crossclamping during vascular surgery repair of thoracic aortic aneurysm, cEPO protected spinal cord function and integrity as eff ective as EPO when applied at equipotent doses. Acknowledgements Supported by the Deutsche Forschungs gemeinschaft (SCHE 899/2-2). References Introduction Unfolded protein response (UPR)-mediated apoptosis plays a pivotal role in ischemia-reperfusion injury. Sodium 4-phenylbutyrate (PBA) has been reported to act as a chemical chaperone inhibiting UPR-mediated apoptosis triggered by ischemia in various organs other than the heart. Therefore we investigated whether PBA reduces UPR-mediated apoptosis and protects against myocardial ischemia-reperfusion injury in mice. Methods C57BL/6 mice were subjected to 30 minutes LAD ischemia followed by reperfusion. PBA (100 mg/kg) or PBS (control) was administrated intraperitoneally just before ischemia. Apoptosis, infarct ...
IntroductionThere is considerable uncertainty about the reproducibility of the various instruments used to measure dyspnea, their ability to reflect changes in symptoms, whether they accurately reflect the patient's experience and if its evolution is similar between acute heart failure syndrome patients and nonacute heart failure syndrome patients. URGENT was a prospective multicenter trial designed to address these issues. Methods Patients were interviewed within 1 hour of first physician evaluation, in the emergency department or acute care setting, with dyspnea assessed by the patient using both a five-point Likert scale and a 10-point visual analog scale (VAS) in the sitting (60º) and then supine (20º) position if dyspnea had not been considered severe or very severe by the sitting versus decubitus dyspnea measurement. Results Very good agreements were found between the five-point Likert and VAS at baseline (0.891, P <0.0001) and between changes (from baseline to hour 6) in the five-point Likert and in VAS (0.800, P <0.0001) in acute heart failure (AHF) patients. Lower agreements were found when changes from baseline to H6 measured by Likert or VAS were compared with the seven-point comparative Likert (0.512 and 0.500 respectively) in AHF patients. The worse the dyspnea at admission, the greater the amplitude of improvement in the first 6 hours; this relationship is stronger when dyspnea is measured with VAS (Spearman's rho coefficient = 0.672) than with the five-point Likert (0.272) (both P <0.0001) in AHF patients. By the five-point Likert, only nine patients (3% (1% to 5%)) reported an improvement in their dyspnea, 177 (51% (46% to 57%)) had no change, and 159 (46% (41% to 52%)) reported worse dyspnea supine compared with sitting up in AHF patients. The PDA test with VAS was markedly different between AHF and non-AHF patients. Conclusions Both clinical tools five-point Likert and VAS showed very good agreement at baseline and between changes from baseline to tests performed 6 hours later in AHF patients. The PDA test with VAS was markedly different between AHF and non-AHF patients. Dyspnea is improved within 6 hours in more than threequarters of the patients regardless of the tool used to measure the change in dyspnea. The greater the dyspnea at admission, the greater the amplitude of improvement in the first 6 hours. Introduction Endotracheal intubation (ETI) engages the patient's life and demands a good experience. A preliminary prospective study has shown in one hospital that emergency physicians (EPs) rarely performed ETI. Do the EPs in Ile de France (Paris region) have sufficient experience and regular training to realise this procedure safely in the emergency room (ER)? Methods We conducted a descriptive telephone-based questionnaire study to assess EPs' endotracheal intubation skills through all ERs in Ile de France public hospitals. A questionnaire was completed by the investigator during a 10-minute telephone call with at least one EP in each ER. The structure of hospitals, number of ETIs perform...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.