Experimental realizations of cold 85 Rb atom interferometers in Wuhan are reviewed in this paper. The application of atom interferometers in local gravity measurement are reported. The resolutions of gravity measurement are 2.0 × 10 −7 g for 1 s and 4.5 × 10 −9 g for 1,888 s. The absolute g value was derived with a difference of 1.6 × 10 −7 g compared to the gravity reference value. The tidal phenomenon was observed by continuously monitoring the local gravity over 123 h. A 10-meter atom interferometer designed for precision gravity measurement and the equivalence principle test is under construction, the latest status is reported for the first time.
Contrast agent free time-of-flight magnetic resonance angiography (TOF-MRA) was applied to the intraluminal thread occlusion model of experimental stroke in rat. It was combined with perfusion- and diffusion-weighted imaging (PWI and DWI) sequences to correlate occlusion and reopening of the middle cerebral artery with alterations in these well-established magnetic resonance sequences. Since TOF-MRA can be repeated without limitations, the time course of vascular patency is demonstrated during an experimental period of up to 8 h (2 h control, 1 h ischemia, 3-6 h reperfusion). With an acquisition time of 10 min, TOF-MRA proved to be suitable to analyze the vascular state of occlusion and reperfusion repetitively in longitudinal studies. Spatial resolution was sufficient to observe neurovascular structural details. In eight out of 10 animals complete vessel occlusion by the intraluminal thread could be validated by an entirely extinguished signal of the ipsilateral middle cerebral artery (MCA) in the angiograms. This was in accordance with a perfusion deficit in the MCA vascular territory detected by PWI (reduction to 30.4 +/- 7.4% relative to contralateral side) and a disturbance of water ion homeostasis monitored by DWI in this area. One animal showed a delayed occlusion after 30 min of MCA occlusion, in another animal vessel occlusion failed. In seven out of the eight successful occlusion experiments there was immediate reperfusion after withdrawal of the thread. One animal showed a delayed reperfusion after suture retraction. Remarkable hemispheric differences in vascular branching of the MCA could be recognized in three out of 10 animals. In conclusion, TOF-MRA is considered a helpful method to survey even in small laboratory animals the correct time course of vascular occlusion and reopening in experimental ischemia, and provides complementary information to the tissue perfusion status monitored by PWI and the ischemic lesion territory detected by DWI.
Bacillus subtilis JA antagonized the growth of Gibberella zeae. In order to reduce growth of this fungi pathogen to a greater extent, low-energy ion beam implantation was applied in mutant breeding. We studied the effects of different energies and different doses of nitrogen ion implantation. The mutant strain designated as JA026 was obtained showing higher inhibition activity in the screening plate. Its inhibition zone against indicator organism increased by 14.3% compared to the original strain. The electrospray ionization mass spectrometry (ESI/MS) analysis indicated that the antifungal lipopeptides produced by the mutant were identical to those produced by the wild-type strain. The mutant strain exhibited favorable properties including the high yield of antifungal lipopeptides production and faster growth over the parent strain, which suggested that this strain would be a promising biocontrol candidate in agriculture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.