Patients with a Type A3 thoracolumbar spine fracture without neurologic deficit should be treated by short-segment posterior stabilization.
Summary Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79). Interpretation In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws. Funding National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
This study shows that osteosynthesis with the PFNA does not improve the position of the implant in the femoral head compared with the PFN. However, the risk of a secondary complication and the necessity of a late reoperation are significantly higher in patients treated with a PFN compared with patients treated with a PFNA.
BackgroundPosttraumatic osteoarthritis can develop after an intra-articular extremity fracture, leading to pain and loss of function. According to international guidelines, anatomical reduction and fixation are the basis for an optimal functional result. In order to achieve this during fracture surgery, an optimal view on the position of the bone fragments and fixation material is a necessity. The currently used 2D-fluoroscopy does not provide sufficient insight, in particular in cases with complex anatomy or subtle injury, and even an 18-26% suboptimal fracture reduction is reported for the ankle and foot. More intra-operative information is therefore needed.Recently the 3D-RX-system was developed, which provides conventional 2D-fluoroscopic images as well as a 3D-reconstruction of bony structures. This modality provides more information, which consequently leads to extra corrections in 18-30% of the fracture operations. However, the effect of the extra corrections on the quality of the anatomical fracture reduction and fixation as well as on patient relevant outcomes has never been investigated.The objective of this study protocol is to investigate the effectiveness of the intra-operative use of the 3D-RX-system as compared to the conventional 2D-fluoroscopy in patients with traumatic intra-articular fractures of the wrist, ankle and calcaneus. The effectiveness will be assessed in two different areas: 1) the quality of fracture reduction and fixation, based on the current golden standard, Computed Tomography. 2) The patient-relevant outcomes like functional outcome range of motion and pain. In addition, the diagnostic accuracy of the 3D-RX-scan will be determined in a clinical setting and a cost-effectiveness as well as a cost-utility analysis will be performed.Methods/designIn this protocol for an international multicenter randomized clinical trial, adult patients (age > 17 years) with a traumatic intra-articular fracture of the wrist, ankle or calcaneus eligible for surgery will be subjected to additional intra-operative 3D-RX. In half of the patients the surgeon will be blinded to these results, in the other half the surgeon may use the 3D-RX results to further optimize fracture reduction. In both randomization groups a CT-scan will be performed postoperatively. Based on these CT-scans the quality of fracture reduction and fixation will be determined. During the follow-up visits after hospital discharge at 6 and 12 weeks and 1 year postoperatively the patient relevant outcomes will be determined by joint specific, health economic and quality of life questionnaires. In addition a follow up study will be performed to determine the patient relevant outcomes and prevalence of posttraumatic osteoarthritis at 2 and 5 years postoperatively.DiscussionThe results of the study will provide more information on the effectiveness of the intra-operative use of 3D-imaging during surgical treatment of intra-articular fractures of the wrist, ankle and calcaneus. A randomized design in which patients will be allocated to a t...
Accidental hypothermia (AH) can be defined as an unintentional decrease in core temperature below 35 degrees C during cold exposure by individuals without intrinsic thermoregulatory dysfunction. Pathophysiological changes can be attributed both to the severity of hypothermia and to co-morbid factors such as trauma, submersion, intoxication and underlying diseases. In trauma victims stratified according to the Injury Severity Score, the factor hypothermia is considered to be a poor prognostic sign for survival. In these patients rewarming therapy should be applied as soon as possible. In the Utrecht University Hospital, adult patients with AH are managed according to an algorithm based on their presenting hemodynamic conditions. Patients with perfusing cardiac rhythms and systolic pressures over 80 mmHg will receive continuous arteriovenous rewarming (CAVR). Arrested and hemodynamically instable patients are treated with cardiopulmonary bypass (CPB). In a 3-year period, 22 patients with AH were admitted to the emergency department. Fourteen patients had a trauma as the cause of hypothermia. Twenty patients were treated according to the algorithm (CAVR n = 18, CPB n = 2) and two patients were alternatively managed. Mortality in the CAVR group was 28% and total mortality reached 32%. Complications of CAVR are related to placement and removal of vascular catheters and may be severe in these patients with impaired coagulation. CAVR permits a good access to the (trauma-) patient and rewarming can be continued synchronously with diagnosis and treatment of various injuries.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.