ABSTRACT.Purpose: To report the outcomes of Boston type I keratoprosthesis (BKPro) in the management of ocular burn injuries. Methods: This was a prospective study including all cases of BKPro implantation for ocular burns at the External Diseases and Cornea Service of the Federal University of Sa˜o Paulo, between February 2008 and February 2010. Ten patients (10 eyes) were enrolled. Procedures performed to manage ocular injury were identified, and data were collected regarding patients' ocular history, surgical procedure(s) performed, and postoperative outcomes, including visual acuity, retention, complications and required surgical procedures. Results: A total of 11 Type 1 BKPro were implanted in 10 eyes of 10 patients. The mean follow-up period was 25.7 ± 10.8 months. Preoperative best-corrected visual acuity (BCVA) ranged from count fingers to light perception. Postoperative BCVA was better than 20 ⁄ 200 in 90% of the patients and better than 20 ⁄ 60 in 60% of the patients. The overall BKPro retention rate was 90%. The most common complications were retroprosthetic membrane formation (50%) and persistent corneal epithelial defect evolving to corneal melting (40%). Patients who underwent ocular surface procedures such as limbal transplantation prior to BKPRo implantation had a lower incidence of corneal melting ⁄ thinning (p = 0.07), although this was not statistically significant. Conclusion: The anatomical and functional results identified in this study support the use of BKPro in managing bilateral limbal stem cell deficiency secondary to ocular burns.
No abstract
Regardless of significant progress in the field of corneal transplantation to treat cor neal opacification, some cases of corneal blindness still present a poor prognosis for conventional penetrating keratoplasty. In patients with repeated graft fai lure and/or with severe ocular surface disease, the Boston type I keratoprosthesis (type I BKPro) has become a viable option. Modifications in its design and postoperative management have improved the longterm outcomes of visual acuity, retention, and postoperative infection rates. These advances made the type I BKPro be considered a safe alternative for visual rehabilitation in many patients with corneal pathologies. However, postoperative handle of chronic comorbidities, such as glaucoma, is still critical for preserving the visual gains achieved with BKPro.
Importance: This study shows that a newer long-arc length intrastromal corneal ring segment is efficient and safe for keratoconus treatment. Background: To evaluate visual, tomographic results and complications of a 320-degree intrastromal corneal ring segment implantation with the femtosecond laser for keratoconus treatment. Design: A prospective, nonrandomized, and interventional study. Participants: A total of 34 eyes of 31 patients diagnosed with keratoconus were enrolled. Methods: Patients were divided into two groups based on the strategy used for 320-degree intrastromal corneal ring segment thickness selection. In one group, this selection was based on spherical equivalent (SE group) and in the other on the mean asphericity (Q group). The uncorrected and corrected distance visual acuities, spherical equivalent, K1, K2, Km, Kmax, and mean asphericity ( Q) on corneal tomography were evaluated preoperatively and at 3 and 6 months postoperatively. For astigmatism improvement, we analyzed the corneal tomographic vectorial astigmatism change preoperatively and at 6 months postoperatively. The mean follow-up period was 6.63 ± 0.96 months. Results: The mean uncorrected distance visual acuity and corrected distance visual acuity improved with a significant spherical equivalent improvement ( p < 0.05), with no differences between the 320-degree intrastromal corneal ring segment groups. All corneal tomographic parameters improved significantly ( p < 0.05) between the preoperative and postoperative intervals, with a significant better performance when we used spherical equivalent for the 320-degree intrastromal corneal ring segment thickness selection. Finally, the mean vectorial corneal tomographic astigmatism significantly improved after 6 months, again with no differences between groups. Conclusion: This study suggests that implanting a 320-degree intrastromal corneal ring segment is a safe and effective procedure for treating patients with keratoconus. It also suggests that for thickness selection spherical equivalent is the better strategy.
Study carried out at the Primeira parte (Questionários): online. Segunda parte (Meeting): OrlandoMiami, USA. Terceira Parte (Análise Estatística): São Paulo (SP), Brazil. ABSTRACTPurpose: To establish current definition, classification and staging, and to develop diagnosis and treatment recommendations for ocular allergy, by using Delphi approach. Methods: Ten Latin American experts on ocular allergy participated in a 4-round Delphi panel approach. Four surveys were constructed and answered by panelists. A two-thirds majority was defined as consensus. Definition, classification, staging and diagnosis and treatment recommendations were the main outcomes.Results: "Ocular allergy" was proposed as the general term to describe ocular allergic diseases. Consensus regarding classification was not reached. Signs and symptoms were considered extremely important for the diagnosis. It was consensus that a staging system should be proposed based on the disease severity. Environmental control, avoidance of allergens and the use of artificial tears were recommended as first line treatment. The secondary treatment should include topical anti-histamines, mast cell stabilizers and multi actions drugs. Topical non-steroidal anti-inflammatory and vasoconstrictors were not recommended. Topical corticosteroids were recommended as third line of treatment for the most severe keratoconjunctivitis. Consensus was not reached regarding the use of systemic corticosteroids or immunosuppressant. Surgical approach and unconventional treatments were not recommended as routine. Conclusion:The task of creating guidelines for ocular allergies showed to be very complex. Many controversial topics remain unsolved. A larger consensus including experts from different groups around the world may be needed to further improve the current recommendations for several aspects of ocular allergy.
Purpose: Epidemiological analysis of limbal transplantation surgeries performed in the Ophthalmologic Hospital of Sorocaba. Methods: Retrospective medical records review of 30 patients who underwent limbal stem cell transplants between January 2003 and March 2008. Cases involving conjunctival limbal autograft were classified as group I, and those involving conjunctival limbal allograft as group II. Results: Two patients were excluded due to incomplete data during postoperative follow-up. Of the total sample of 28 patients, 53.6% constituted group I, whereas 46.4% were included in group II. Males were predominant (67.9%), and right eyes were the most prevalent (67.9%). The mean age was 40.3 years. Unilateral cases accounted for 60.7%. The most frequent pathology causing limbal system failure was chemical burns (53%). The mean length of time from diagnosis to surgery was 11.18 years. The limbal graft and amniotic membrane were associated in 75% of all cases, and tarsorrhaphy in 57.1%. The average follow-up period was 24.84 months. The uncorrected visual acuity improved in 38% of the cases, was unchanged in 28.5%, and deteriorated in 33.3%. There was no persistent epithelial defect in 75% of the patients. The conjunctivalization rate was similar between the groups (53.3% and 58.3%, respectively). The transparency improved in only 38.4% of the cases, and 28.5% of the surgeries performed were successful. The most prevalent complication was persistent epithelial defect, which occurred in 25% of the patients, followed by corneal melting in 14.2%. Other complications observed included infectious ulcers, limbal graft necrosis or ischemia, perforation, and descemetocele. Conclusion: Chemical burns remain the main cause of limbal stem cell deficiency. In these cases, limbal transplantation is the standard procedure to restore the ocular surface even though the success rate is low. Keywords
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.