We report on the observation of incoherent Cherenkov radiation emitted by a 5.3 GeV positron beam circulating in the Cornell electron-positron storage ring as the beam passes in the close vicinity of the surface of a fused silica radiator (i.e., at a distance larger than 0.8 mm). The shape of the radiator was designed in order to send the Cherenkov photons towards the detector, consisting of a compact optical system equipped with an intensified camera. The optical system allows both the measurements of 2D images and angular distribution including polarization study. The corresponding light intensity has been measured as a function of the distance between the beam and the surface of the radiator and has shown a good agreement with theoretical predictions. For highly relativistic particles, a large amount of incoherent radiation is produced in a wide spectral range. A light yield of 0.8×10^{-3} photon per particle per turn has been measured at a wavelength of 600±10 nm in a 2 cm long radiator and for an impact parameter of 1 mm. This will find applications in accelerators as noninvasive beam diagnostics for both leptons and hadrons.
In the framework of the future linear collider collaboration (CLIC, ILC), non-intercepting beam monitoring instruments are under development for very low emittance and high charge density beams. Optical diffraction radiation (ODR) was studied and developed during the last years focussing on beam size measurements. We propose in the paper to consider the use of diffraction radiation for ultra relativistic beams as position monitors with applications for the centering of scrapers, collimators and targets with high resolution. We present the experimental results obtained using small aperture slits on the ATF2 extraction beam line at KEK and on the Cornell Electron Storage Ring with 1.2 GeV and 2.1 GeV electrons respectively.
In recent years, there has been an increasing demand for noninvasive beam size monitoring on particle accelerators. Ideally, these monitors should be cost effective and require little or no maintenance. These monitors should also be suitable for both linear and circular machines. Here, the experimental setup is described in detail, and the results from a diffraction radiation beam size monitor are presented. This monitor has been tested on the Cornell Electron Storage Ring using a 1 mA (1.6 × 10 10 particles per bunch) single bunch electron beam at 2.1 GeV energy. Images of the target surface and the angular distribution of the emitted diffraction radiation were acquired at wavelengths of 400 and 600 nm. These measurements are compared to two analytical models.
Charged particle beam diagnostics is a key task in modern and future accelerator installations. The diagnostic tools are practically the "eyes" of the operators. The precision and resolution of the diagnostic equipment are crucial to define the performance of the accelerator. Transition and diffraction radiation (TR and DR) are widely used for electron beam parameter monitoring. However, the precision and resolution of those devices are determined by how well the production, transport and detection of these radiation types are understood. This paper reports on simulations of TR and DR spatial-spectral characteristics using the physical optics propagation (POP) mode of the Zemax advanced optics simulation software. A good consistency with theory is demonstrated. Also, realistic optical system alignment issues are discussed.
Realtime
in situ
temperature monitoring in difficult experimental conditions or inaccessible environments is critical for many applications. Non-contact luminescence decay time thermometry is often the method of choice for such applications due to a favorable combination of sensitivity, accuracy and robustness. In this work, we demonstrate the feasibility of an ultrafast PbI
2
scintillator for temperature determination, using the time structure of X-ray radiation, produced by a synchrotron. The decay kinetics of the scintillations was measured over the 8–107 K temperature range using monochromatic pulsed X-ray excitation. It is found that lead iodide exhibits a very fast and intense scintillation response due to excitons and donor-acceptor pairs, with the fast decay component varying between 0.08 and 0.5 ns – a feature that can be readily exploited for temperature monitoring. The observed temperature dependence of the decay time is discussed in terms of two possible mechanisms of thermal quenching – transition over activation barrier and phonon-assisted escape. It is concluded that the latter provides a better fit to the experimental results and is consistent with the model of luminescence processes in PbI
2
. We evaluated the sensitivity and estimated the accuracy of the temperature determination as ca. ±6 K at 107 K, improving to ±1.4 K at 8 K. The results of this study prove the feasibility of temperature monitoring, using ultrafast scintillation of PbI
2
excited by X-ray pulses from a synchrotron, thus enabling non-contact
in-situ
cryothermometry with megahertz sampling rate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.