This first multicentre retrospective study of assisted reproduction following sperm washing demonstrates the method to be effective and to significantly reduce HIV-1 transmission risk to the uninfected female partner. These results support the view that assisted reproduction with sperm washing could not be denied to serodiscordant couples in developed countries and, where possible, could perhaps be integrated into a global public health initiative against HIV in developing countries.
The aim of this study was to examine the relationship between visual field (VF) loss, vision-related quality of life (QoL) and glaucoma-related symptoms in a large cohort of primary open angle glaucoma (POAG) patients. POAG patients with or without VF defects or “glaucoma suspect” patients were considered eligible. QoL was assessed using the validated versions of the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25) and glaucoma-related symptoms were assessed using the Glaucoma Symptom Scale (GSS). Patients were classified as having VF damage in one eye (VFD-1), both eyes (VFD-2), or neither eye (VFD-0). 3227 patients were enrolled and 2940 were eligible for the analysis. 13.4% of patients were classified in the VFD-0, 23.7% in the VFD-1, and 62.9% in the VFD-2 group. GSS visual symptoms domain (Func-4) and GSS non-visual symptoms domain (Symp-6) scores were similar for the VFD-0 and VFD-1 groups (p = 0.133 and p = 0.834 for Func-4 and Symp-6, respectively). VFD-0 group had higher scores than VFD-2 both in Func-4 (p < 0.001) and Symp-6 domains (p = 0.035). Regarding the NEI-VFQ-25, our data demonstrated that bilateral VF defects are associated with vision-related QoL deterioration, irrespective of visual acuity.
ABSTRACT.Purpose: As a progressive condition, glaucoma may impair health-related quality of life (HRQoL), due to vision loss and other factors. This study evaluated HRQoL in a cohort of patients treated for primary open-angle glaucoma (POAG) and assessed its association with clinical features. Methods: This was an Italian, multicentre, cross-sectional, observational study with the subgroup of newly diagnosed patients with POAG prospectively followed up for one year. Patients with previous or new diagnosis (or strong clinical suspicion) of POAG aged >18 years were considered eligible. Information was collected on demographic characteristics, medical history, clinical presentation and POAG treatments. HRQoL was measured using the 25-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-25) and Glaucoma Symptom Scale (GSS). Subscale and total scores were obtained and a Pearson correlation coefficient between instruments' scores calculated. Results: A total of 3227 patients were enrolled from 2012 to 2013 and 3169 were analysed. Mean age was 66.9 years. A total of 93.8% had a previous diagnosis (median duration: 8.0 years). Median values for mean deviation and pattern standard deviation were 3.9 and 3.6 dB, respectively. Mean scores on most subscales of the NEI-VFQ-25 exceeded 75.0 and mean GSS subscale scores ranged between 70.8 and 79.7 (with a total mean score of 74.8). HRQoL scores on both scales were significantly inversely associated with POAG severity. Conclusion: In this large sample of Italians treated for POAG, disease severity was limited and HRQoL scores were high. QoL decreased with advancing disease severity. These findings confirm the role of vision loss in impairing QoL in POAG, underlying the importance of timely detection and appropriate treatment.
Couples in whom the man is HIV-1-positive may use medically assisted procreation in order to conceive a child without contaminating the female partner. But, before medically assisted procreation, the semen has to be processed to exclude HIV and tested for HIV nucleic acid before and after processing. The performance was evaluated of the technical protocols used to detect and quantify HIV-1 in 11 centers providing medically assisted procreation for couples with HIV-1 infected men by testing panels of seminal plasma and cells containing HIV-1 RNA and/or DNA. The performance of these tests varied due to the different assays used. False positive results were obtained in 14-19% of cases. The sensitivity for RNA detection in seminal plasma was 500-1,000 RNA copies/ml, over 500 RNA copies/10(6) cells in semen cells, and for DNA detection in semen cells 50-500 DNA copies/10(6) cells. The use of silica-based extraction seemed to increase the assay performance, whereas the use of internal controls to detect PCR inhibitor did not. This first quality control highlights the need for technical improvements of the assays to detect and quantify HIV in semen fractions and for regular evaluation of their performance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.