Among the applications for protic ionic liquids (PILs), lubrication is one of the newest and the most promising. In this work, ammonium-based protic ionic liquids were tested as lubricant fluids for aluminum-steel contacts. PILs were synthesized with 2-hydroxyethylamine (2HEA) and a carboxylic acid (formic and pentanoic), aiming to understand the effect of two different anion chain lengths on the lubricant behavior. The synthesized PILs were characterized by RMN, FTIR and TGA. Wear tests, conducted using a ball-on-plate configuration, showed that the increase of the anion carbon chain length in the PIL structure reduced significantly the coefficient of friction value. Besides, after the wear tests, the PILs structural integrity was not affected. In the same way, bending under tension (BUT) tests evidenced that the performance for stamping conditions of the PIL with the longest anion carbon chain was similar to that of the commercial lubricant. Since, both formed a uniform tribofilm, developed the same lubrication regime and the drawing forces values were close and constant. Hence, the ionic liquid obtained with 2HEA and pentanoic acid (2HEAPe) is as suitable as the commercial lubricant for metal forming processes.
Introduction: This work aims to pre-operatively manufacture custom-made low-cost implants and physical models ('biomodels') of fractured skulls. The pre-operative manufacturing of biomodels and implants allows physicians to study and plan surgery with a greater possibility of achieving the expected result. Customization contributes to both the esthetic and functional outcome of the implant because it considers the anatomy of each patient, while the low cost allows a greater number of people to potentially benefi t. Methods: From CT images of a fractured skull, a CAD model of the skull (biomodel) and a restorative implant were constructed digitally. The biomodel was then physically constructed with 3D Printing, and Incremental Sheet Forming (ISF) was used to manufacture the implant from a sheet of pure grade 2 titanium. Before cutting the implant's fi nal shape from a pre-formed sheet, heat treatment was performed to avoid deformations caused by residual stresses generated during the ISF process. Results: A comparison of the dimensions of the implant and its respective CAD biomodel revealed geometric discrepancies that can affect both functional and aesthetic effi ciency. Nevertheless, the fi nal shape preserved symmetry between the right and left sides of the skull. Electron microscopy analysis did not indicate the presence of elements other than pure titanium. Conclusions: Dimensional variability can be decreased with changes in the manufacturing process (i.e., forming and cutting) and the heating ramp. Despite biomedical characteristics, there was no contamination of the implant by harmful chemical elements. 3D Printing was effective in making the biomodel, enabling pre-operative planning and improving physicianpatient communication. Current results indicate that ISF is a process that can be used to obtain custom-made implants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.