Summary
Background
Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes.
Methods
For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813.
Findings
Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79).
Interpretation
In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws.
Funding
National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
Femoral and tibial tunnel widening following ACL reconstruction using hamstring autograft has been described. Greater tunnel widening has been reported with suspensory fixation systems. We hypothesized that greater tunnel widening will be observed in patients whose hamstring autograft was fixated using a cortical, suspensory system, compared to double cross-pin fixation on the femur. We performed clinical and radiographic evaluation on 46 patients at minimum 2 years after primary ACL reconstruction. We measured subjective and objective outcomes including KT-1000 and AP, lateral radiographs. A musculoskeletal radiologist, independent of the surgical team, measured tunnel width, while correcting for magnification, at the widest point and at 1 cm away from tibial and femoral tunnel apertures. Patients in the suspensory graft fixation group exhibited significantly greater absolute change and greater percent change in femoral tunnel diameter compared to patients with double cross-pin fixation (P
This study compared the graft/femoral tunnel angle produced with the outside-in technique with the inside-out technique at 90° and 120° of flexion. Three femoral tunnels were marked with guidewires and measured radiographically in 8 fresh-frozen cadaveric knees using both techniques. Results were analyzed. The mean graft/femoral tunnel angle was 34.4°614.4° for the outside-in technique, 52.3°614.1° for the inside-out technique at 120° of flexion, and 74.4°611° for the inside-out technique at 90° of flexion. The angle was smaller for the outside-in technique versus the inside-out technique at both 120° (P = .019) and 90° of knee flexion (P , .001). The outside-in technique for femoral tunnel placement produces the lowest graft/femoral tunnel angle in cadavers. With the inside-out technique, 120º of flexion produces smaller angles than does 90º of flexion. The outside-in technique results in lower angles and perhaps lower graft failure rates. However, additional clinical studies are needed. [J Knee Surg. 2009;22:106-110.]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.