Bacteria communicate by producing quorum sensing molecules called autoinducers, which include autoinducer-1, an N-hexanoyl homoserine lactone (AHL), and autoinducer-2. Bacteria present in the human oral cavity have been shown to produce autoinducer-2, but not AHL. Here, we report the isolation of two AHL-producing Klebsiella pneumoniae strains from the posterior dorsal surface of the tongue of a healthy individual. Spent culture supernatant extracts from K. pneumoniae activated the biosensors Agrobacterium tumefaciens NTL4(pZLR4) and Escherichia coli [pSB401], suggesting the presence of both long and short chain AHLs. High resolution mass spectrometry analyses of these extracts confirmed that both K. pneumoniae isolates produced N-octanoylhomoserine lactone and N-3-dodecanoyl-l-homoserine lactone. To the best of our knowledge, this is the first report of the isolation of K. pneumoniae from the posterior dorsal surface of the human tongue and the production of these AHLs by this bacterium.
We report the isolation of N-acyl homoserine lactone-producing Enterobacter sp. isolate T1-1 from the posterior dorsal surfaces of the tongue of a healthy individual. Spent supernatants extract from Enterobacter sp. isolate T1-1 activated the biosensor Agrobacterium tumefaciens NTL4(pZLR4), suggesting production of long chain AHLs by these isolates. High resolution mass spectrometry analysis of these extracts confirmed that Enterobacter sp. isolate T1-1 produced a long chain N-acyl homoserine lactone, namely N-dodecanoyl-homoserine lactone (C12-HSL). To the best of our knowledge, this is the first isolation of Enterobacter sp., strain T1-1 from the posterior dorsal surface of the human tongue and N-acyl homoserine lactones production by this bacterium.
This study aimed to test the sterility of new unused orthodontic buccal tubes received from manufacturers. Four different types of buccal tubes were used straight from the manufactures package without any additional sterilizing step. Of these buccal tubes tested, three genera of bacteria, implicated as opportunistic pathogens, namely Micrococcus luteus, Staphylococcus haemolyticus and Acinetobacter calcoaceticus were recovered from these buccal tubes. Our data showing microbial contamination on buccal tubes highlights the need of sterilization before clinical use. We also suggest that manufacturers should list the sterility state of orthodontic buccal tubes on their packaging or instructions stating the need for sterilization.
Intermaxillary (IMF) screws feature several advantages over other devices used for intermaxillary fixation, but using cone beam computed tomography (CBCT) scans to determine the safe and danger zones to place these devices for all patients can be expensive. This study aimed to determine the optimal interradicular and buccopalatal/buccolingual spaces for IMF screw placement in the maxilla and mandible. The CBCT volumetric data of 193 patients was used to generate transaxial slices between the second molar on the right to the second molar on the left in both arches. The mean interradicular and buccopalatal/buccolingual distances and standard deviation values were obtained at heights of 2, 5, 8 and 11 mm from the alveolar bone crest. An IMF screw with a diameter of 1.0 mm and length of 7 mm can be placed distal to the canines (2 - 11 mm from the alveolar crest) and less than 8 mm between the molars in the maxilla. In the mandible, the safest position is distal to the first premolar (more than 5 mm) and distal to the second premolar (more than 2 mm). There was a significant difference (p<0.05) between the right and left quadrants. The colour coding 3D template showed the safe and danger zones based on the mesiodistal, buccopalatal and buccolingual distances in the maxilla and mandible.The safest sites for IMF screw insertion in the maxilla were between the canines and first premolars and between the first and second molars. In the mandible, the safest sites were between the first and second premolars and between the second premolar and first molar. However, the IMF screw should not exceed 1.0 mm in diameter and 7 mm in length.
Orangutans are believed to have close biological affinities to humans. Teeth being the hardest tissue provide useful information on primate evolution. Furthermore, knowledge of the pulp chamber and root canal morphology is important for dental treatment. A female Bornean orangutan and a Sumatran male orangutan skull were available for this study. Both of their dentitions, comprising 50 teeth, were scanned employing the cone-beam computed tomography for both metrical and nonmetrical analyses. Measurements included tooth and crown length, root length, enamel covered crown height, root canal length (posterior teeth), length of pulpal space (anterior teeth), and root canal width. Nonmetrical parameters included number of canals per root, number of foramina in each root, and root canal morphology according to Vertucci's classification. It was found that the enamel covered crown height was the longest in the upper central incisors although the canine was the longest amongst the anterior teeth. Both the upper premolars were three-rooted while the lower second premolar of the Sumatran orangutan was two-rooted, with two foramina. The mandibular lateral incisors of the Bornean orangutan were longer than the central incisors, a feature similar to humans. In addition, secondary dentine deposition was noticed, a feature consistent with aged humans.
Introduction:In orthodontic treatment, three-dimensional (3D) dental casts has a significant role in diagnosis and treatment planning. The aim of this study was to evaluate Pont's index predictability in orthodontics.Materials and Methods:Premolar arch width, molar arch width and mesiodistal width of the maxillary incisors were measured three-dimensionally to assess shape of dental arches. The data source was cone beam computed tomography (CBCT) high volumetric data acquisitions from Malay ethnic background. Arch widths were measured and recorded from 53 subjects (32 male and 21 female with the mean age, 25.81), both the maxillary and mandibular arches, to obtain CBCT high volumetric data. All measurements were obtained through CBCT Planmeca Romexis TM Software 2.3.1.R (Helsinki, Finland).Results:Pont's formula overestimated the upper and lower interpremolar distance, with mean differences of 8.35 ± 3 mm and 12.02 ± 3.20 mm, respectively. Furthermore, the formula overestimated the upper and lower intermolar distance, with mean differences of 7.87 ± 3 mm and 16.14 ± 5.86 mm, respectively.Conclusions:The results indicate that Pont's index is not practical for use with the Malaysian population since the index overestimated interpremolar and intermolar widths. This raises questions whether the index is a true predictor of arch width measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.