Background Recently, reports of unwanted tooth movements despite intact orthodontic bonded retainers have increased. These movements are not subject to relapse but are classified as a new developed malocclusion. The aims of the present pilot study were to analyze the prevalence of unwanted tooth movements despite intact bonded cuspid-to-cuspid retainers and to identify possible predisposing factors. Materials and methods Plaster casts of all patients finishing orthodontic treatment during three consecutive years were assessed before treatment (T0), after multibracket appliance debonding (T1) and after two years of retention (T2). After multibracket appliance treatment, all patients received a cuspid-to-cuspid flexible spiral wire retainer bonded to each tooth of the retained segment in the upper and lower jaw. The study group (SG) consisted of 44 patients (16 male, 28 female) with tooth movements (T1–T2) of the retained segment despite intact bonded cuspid-to-cuspid retainer and the control group (CG) of 43 patients (19 male, 24 female) without unwanted tooth movements. The casts of the SG were digitized, superimposed and measured. Using the Chi-square test, Fisher´s exact test and Mann–Whitney-U-test (p < 0.05), mandibular plane angle, incisor proclination, oral dysfunctions or habits (T0) and intercanine distance, overjet and interincisal relationship (T0, T1, T2) were compared between SG and CG. Results The prevalence of patients with unwanted tooth movements in one or both jaws was 27.0%. Maxillary retainers were affected more often (20.9%) than mandibular retainers (14.1%). The median amount of tooth movements was 0 to 0.66 mm with large interindividual variations. Oral dysfunctions or habits at T0, such as a lack of interincisal contact at all time points, were associated with unwanted tooth movements. Conclusion Unwanted tooth movements occurred more often with maxillary than mandibular retainers. Patients with oral dysfunctions/habits and without interincisal contact had a higher prevalence of unwanted tooth movements.
Due to the high prevalence of periodontitis, dentists have to face a larger group of patients with periodontally compromised dentitions (PCDs) characterized by pathologic tooth migration and malocclusion. Impression taking in these patients is challenging due to several undercuts and extensive interdental areas (IAs). The aim of this clinical trial was to analyze the ability of analog and digital impression techniques to display the IAs in PCDs. The upper and the lower jaws of 30 patients (n = 60, age: 48–87 years) were investigated with one conventional impression (CVI) using polyvinyl siloxane and four digital impressions with intraoral scanners (IOSs), namely True Definition (TRU), Primescan (PRI), CS 3600 (CAR), and TRIOS 3 (TIO). The gypsum models of the CVIs were digitalized using a laboratory scanner. Subsequently, the percentage of the displayed IAs in relation to the absolute IAs was calculated for the five impression techniques in a three-dimensional measuring software. Significant differences were observed among the impression techniques (except between PRI and CAR, p-value < 0.05). TRU displayed the highest percentage of IAs, followed by PRI, CAR, TIO, and CVI. The results indicated that the IOSs are superior to CVI regarding the ability to display the IAs in PCDs.
BackgroundThe present study aimed to investigate the prevalence of oral microbiota (Candida species (spp.), Streptococcus mutans, and Lactobacilli) in patients with multibracket (MB) appliances in relation to the quality of oral hygiene.Saliva and plaque samples were collected from three groups of 25 patients each (good oral hygiene (GOH), poor oral hygiene (POH), and poor oral hygiene with white spot lesions (POH/WSL)). Counts of colony forming units (CFU) of the investigated oral microbiota were compared using Chi-square and Mann–Whitney U tests.ResultsBoth saliva and plaque samples showed a high prevalence of Candida spp. in all patients (saliva: 73.4 %, plaque: 60.9 %). The main Candida species was C. albicans. The salivary CFU of Candida spp. in the GOH group was significantly lower than that in the POH group (p = 0.045) and POH/WSL group (p = 0.011). S. mutans was found in the saliva and plaque samples of all patients. Lactobacilli were found in the saliva samples of all patients and in 90.7 % of the plaque samples. In the saliva samples, the CFU of Lactobacilli were more numerous in the POH and POH/WSL groups than in the GOH group (p = 0.047).ConclusionsThe investigated sample of patients showed a high carriage of oral Candida spp. Patients with WSL formation during MB appliance treatment exhibited higher counts of Candida and Lactobacilli compared with patients with good oral hygiene. Independent of oral hygiene quality, S. mutans was detected in all patients.
Patient cooperation remains the outstanding parameter determining treatment success. A proportionally higher frequency of unacceptable treatment results must be expected in patients with open bite configurations (skeletally, dentally, and functionally).
About 40% of the adult population is affected by snoring, which is closely related to obstructive sleep apnea (OSA) and can be associated with serious health implications. Commercial smartphone applications (apps) offer the possibility of monitoring snoring at home. However, the number of validation studies addressing snoring apps is limited. The purpose of the present study was to assess the accuracy of recorded snoring using the free version of the app SnoreLab (Reviva Softworks Ltd., London, United Kingdom) in comparison to a full-night polygraphic measurement (Miniscreen plus, Löwenstein Medical GmbH & Co., KG, Bad Ems, Germany). Nineteen healthy adult volunteers (4 female, 15 male, mean age: 38.9 ± 19.4 years) underwent simultaneous polygraphic and SnoreLab app measurement for one night at home. Parameters obtained by the SnoreLab app were: starting/ending time of monitoring, time in bed, duration and percent of quiet sleep, light, loud and epic snoring, total snoring time and Snore Score, a specific score obtained by the SnoreLab app. Data obtained from polygraphy were: starting/ending time of monitoring, time in bed, total snoring time, snore index (SI), snore index obstructive (SI obstructive) and apnea-hypopnea-index (AHI). For different thresholds of percentage snoring per night, accuracy, sensitivity, specificity, positive and negative predictive values were calculated. Comparison of methods was undertaken by Spearman-Rho correlations and Bland-Altman plots. The SnoreLab app provides acceptable accuracy values measuring snoring >50% per night: 94.7% accuracy, 100% sensitivity, 94.1% specificity, 66.6% positive prediction value and 100% negative prediction value. Best agreement between both methods was achieved in comparing the sum of loud and epic snoring ratios obtained by the SnoreLab app with the total snoring ratio measured by polygraphy. Obstructive events could not be detected by the SnoreLab app. Compared to polygraphy, the SnoreLab app provides acceptable accuracy values regarding the measurement of especially heavy snoring.
the purpose of the present cross-sectional clinical study was to check the ability of plaque detection and quantification by QLF-D against conventional digital photographs of disclosed plaque in multibracket appliance (MB) patients. 20 patients were included according to the following criteria: (1) upper and lower jaw treated by MB appliance, (2) patients being 16 years of age or older, (3) all central and lateral incisors as well as canines in situ, (4) absence of developmental defects, carious lesions, surface fillings, prosthetic restorations or recessions greater than 1/3 of root length in central/lateral incisors and canines as well as (5) declaration of consent. QLF-D and conventional photographs were analyzed planimetrically regarding plaque coverage on buccal and oral surfaces of central/lateral incisors and canines. the conventional photographs of stained plaque served as gold standard. on average, in QLF-D pictures 20.7% ± 17.4 of the tooth surfaces were covered with plaque, while the conventional photographs of disclosed plaque presented a mean plaque-covered area of 36.2% ± 23.5. The Bland-Altman plot for both imaging modalities showed a very large inconsistent scattering with both negative and positive deviations. the method discrepancy increased with increasing plaque coverage, thus indicating a systematic method error. on average, the deviation of the methods from the optimal line of accordance was −15.5%. In patients wearing MB appliances, there was no clinical significant agreement regarding the plaque-covered tooth surface depicted by QLf-D respectively conventional images of disclosed plaque. Due to the large method discrepancy, QLf-D is currently not reliable for precise plaque quantification in MB patients. Plaque control during multibracket appliance (MB) treatment is a special challenge because a MB inevitably increases the number of retentive niches for plaque accumulation. Detection and quantification of dental plaque plays an important role in everyday practice, both for patients' education and motivation. In addition, it is also important for clinical research. Due to the buccal and/or lingual attachments and wires of a MB appliance, modified plaque indices have been developed for use in orthodontic patients 1,2. Although plaque indices allow for a fast assessment of the amount and localization of plaque, they have their disadvantages especially for research purposes, as due to their subjective nature time-and cost-intensive examiner training for calibration and reliability is required. Furthermore, the comparison of different study results is hindered by the variety of indices used. In addition, due to their ordinal scaled nature, the discriminating capacity of some indices is insufficient because of their limited number
Objectives The aim of this in vitro study was to investigate the influence of fixed orthodontic appliances (FOAs) on the transfer accuracy of full-arch impressions by five intraoral scanners (IOSs): CS3600, Primescan, Trios 4, Medit i500, Emerald S, and one conventional alginate impression (CAI). Materials and methods To compare the data with the actual model situation, an established reference aid–based method was applied. A test model with human teeth was used and modified for each testing group, resulting in five different settings: natural teeth (group A), metal brackets without/with wire (groups B/C), ceramic brackets without/with wire (groups D/E). A total of 300 (n = 12 × 5 × 5) scan datasets of IOSs were analyzed using a 3D software (GOM Inspect) and 60 (n = 12 × 5) plaster casts of CAI were measured with a coordinate measurement machine. The deviations between the reference aid and the impressions were determined. Results For all groups with brackets (B to E), IOSs showed a higher transfer accuracy compared to CAI, even for long-span distances. However, some significant differences between the IOSs were observed (p < 0.05). Conclusions Within the limitations of this in vitro study, IOSs can be recommended for impressions with and without FOAs, even if CAI showed the smallest average deviations in settings without FOAs. Clinical relevance IOSs are widely used in orthodontics and the current study demonstrated that their use enables fast impression taking even in settings with fixed orthodontic appliances. In addition, for these settings, the transfer accuracy is higher than with conventional alginate impressions. Nevertheless, a re-investigation in a clinical setting should be performed to verify the current in vitro findings.
The lower the pretreatment VAS score and the profile convexity angles or the larger the pretreatment ANB angles were, the more the VAS improved. Pretreatment thresholds for consistent improvements were as follows: VAS score < 20 mm, ANB > 8°, and profile angle ≤ 155°.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.