2022
DOI: 10.1007/s00784-022-04721-5
|View full text |Cite
|
Sign up to set email alerts
|

The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid–based in vitro study

Abstract: Objectives The aim of this in vitro study was to investigate the influence of fixed orthodontic appliances (FOAs) on the transfer accuracy of full-arch impressions by five intraoral scanners (IOSs): CS3600, Primescan, Trios 4, Medit i500, Emerald S, and one conventional alginate impression (CAI). Materials and methods To compare the data with the actual model situation, an established reference aid–based method was applied. A test model with human … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
6
1

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(8 citation statements)
references
References 31 publications
(63 reference statements)
1
6
1
Order By: Relevance
“…However, the accuracy of digital impression-taking with an IOS differs a lot when comparing dental arches with and without a bonded MBA. While two prior in vitro studies determined no clinically relevant effect of MBAs on the impression accuracy [14,15], more recent investigations described a distinct reduction in the transfer accuracy for full-arch impressions [16][17][18]. The effect, however, is still acceptable when compared to the data determined for CAIs [18].…”
Section: Introductionmentioning
confidence: 96%
See 4 more Smart Citations
“…However, the accuracy of digital impression-taking with an IOS differs a lot when comparing dental arches with and without a bonded MBA. While two prior in vitro studies determined no clinically relevant effect of MBAs on the impression accuracy [14,15], more recent investigations described a distinct reduction in the transfer accuracy for full-arch impressions [16][17][18]. The effect, however, is still acceptable when compared to the data determined for CAIs [18].…”
Section: Introductionmentioning
confidence: 96%
“…Regarding the amount of time needed to obtain a full-arch impression, several studies have been published [11,13,[18][19][20]. While CAIs might demand the lowest amount of chairside time for the impression itself, the chairside time to remove and reinsert the archwire-which is recommended for improved impression quality and reduced patient discomfort-as well as the duration of the subsequent obligatory CPC process in the dental laboratory need to be considered.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations