Summary The potential aerosolised transmission of severe acute respiratory syndrome coronavirus‐2 is of global concern. Airborne precaution personal protective equipment and preventative measures are universally mandated for medical procedures deemed to be aerosol generating. The implementation of these measures is having a huge impact on healthcare provision. There is currently a lack of quantitative evidence on the number and size of airborne particles produced during aerosol‐generating procedures to inform risk assessments. To address this evidence gap, we conducted real‐time, high‐resolution environmental monitoring in ultraclean ventilation operating theatres during tracheal intubation and extubation sequences. Continuous sampling with an optical particle sizer allowed characterisation of aerosol generation within the zone between the patient and anaesthetist. Aerosol monitoring showed a very low background particle count (0.4 particles.l −1 ) allowing resolution of transient increases in airborne particles associated with airway management. As a positive reference control, we quantitated the aerosol produced in the same setting by a volitional cough (average concentration, 732 (418) particles.l −1 , n = 38). Tracheal intubation including facemask ventilation produced very low quantities of aerosolised particles (average concentration, 1.4 (1.4) particles.l −1 , n = 14, p < 0.0001 vs. cough). Tracheal extubation, particularly when the patient coughed, produced a detectable aerosol (21 (18) l −1 , n = 10) which was 15‐fold greater than intubation (p = 0.0004) but 35‐fold less than a volitional cough (p < 0.0001). The study does not support the designation of elective tracheal intubation as an aerosol‐generating procedure. Extubation generates more detectable aerosol than intubation but falls below the current criterion for designation as a high‐risk aerosol‐generating procedure. These novel findings from real‐time aerosol detection in a routine healthcare setting provide a quantitative methodology for risk assessment that can be extended to other airway management techniques and clinical settings. They also indicate the need for reappraisal of what constitutes an aerosol‐generating procedure and the associated precautions for routine anaesthetic airway management.
Introductioncontinuous positive airway pressure (CPAP) and high-flow nasal oxygen (HFNO) provide enhanced oxygen delivery and respiratory support for patients with severe COVID-19. CPAP and HFNO are currently designated as aerosol-generating procedures despite limited high-quality experimental data. We aimed to characterise aerosol emission from HFNO and CPAP and compare with breathing, speaking and coughing.Materials and methodsHealthy volunteers were recruited to breathe, speak and cough in ultra-clean, laminar flow theatres followed by using CPAP and HFNO. Aerosol emission was measured using two discrete methodologies, simultaneously. Hospitalised patients with COVID-19 had cough recorded using the same methodology on the infectious diseases ward.ResultsIn healthy volunteers (n=25 subjects; 531 measures), CPAP (with exhalation port filter) produced less aerosol than breathing, speaking and coughing (even with large >50 L/min face mask leaks). Coughing was associated with the highest aerosol emissions of any recorded activity. HFNO was associated with aerosol emission, however, this was from the machine. Generated particles were small (<1 µm), passing from the machine through the patient and to the detector without coalescence with respiratory aerosol, thereby unlikely to carry viral particles. More aerosol was generated in cough from patients with COVID-19 (n=8) than volunteers.ConclusionsIn healthy volunteers, standard non-humidified CPAP is associated with less aerosol emission than breathing, speaking or coughing. Aerosol emission from the respiratory tract does not appear to be increased by HFNO. Although direct comparisons are complex, cough appears to be the main aerosol-generating risk out of all measured activities.
ObjectiveTo determine if oesophago-gastro-duodenoscopy (OGD) generates increased levels of aerosol in conscious patients and identify the source events.DesignA prospective, environmental aerosol monitoring study, undertaken in an ultraclean environment, on patients undergoing OGD. Sampling was performed 20 cm away from the patient’s mouth using an optical particle sizer. Aerosol levels during OGD were compared with tidal breathing and voluntary coughs within subject.ResultsPatients undergoing bariatric surgical assessment were recruited (mean body mass index 44 and mean age 40 years, n=15). A low background particle concentration in theatres (3 L−1) enabled detection of aerosol generation by tidal breathing (mean particle concentration 118 L−1). Aerosol recording during OGD showed an average particle number concentration of 595 L−1 with a wide range (3–4320 L−1). Bioaerosol-generating events, namely, coughing or burping, were common. Coughing was evoked in 60% of the endoscopies, with a greater peak concentration and a greater total number of sampled particles than the patient’s reference voluntary coughs (11 710 vs 2320 L−1 and 780 vs 191 particles, n=9 and p=0.008). Endoscopies with coughs generated a higher level of aerosol than tidal breathing, whereas those without coughs were not different to the background. Burps also generated increased aerosol concentration, similar to those recorded during voluntary coughs. The insertion and removal of the endoscope were not aerosol generating unless a cough was triggered.ConclusionCoughing evoked during OGD is the main source of the increased aerosol levels, and therefore, OGD should be regarded as a procedure with high risk of producing respiratory aerosols. OGD should be conducted with airborne personal protective equipment and appropriate precautions in those patients who are at risk of having COVID-19 or other respiratory pathogens.
Many guidelines consider supraglottic airway use to be an aerosol-generating procedure. This status requires increased levels of personal protective equipment, fallow time between cases and results in reduced operating theatre efficiency. Aerosol generation has never been quantitated during supraglottic airway use. To address this evidence gap, we conducted real-time aerosol monitoring (0.3-10-µm diameter) in ultraclean operating theatres during supraglottic airway insertion and removal. This showed very low background particle concentrations (median (IQR [range]) 1.6 (0-3.1 [0-4.0]) particles.l À1 ) against which the patient's tidal breathing produced a higher concentration of aerosol (4.0 (1.3-11.0 [0-44]) particles.l À1 , p = 0.048). The average aerosol concentration detected during supraglottic airway insertion (1.3 (1.0-4.2 [0-6.2]) particles.l À1 , n = 11), and removal (2.1 (0-17.5 [0-26.2]) particles.l À1 , n = 12) was no different to tidal breathing (p = 0.31 and p = 0.84, respectively). Comparison of supraglottic airway insertion and removal with a volitional cough (104 (66-169 [33-326]), n = 27), demonstrated that supraglottic airway insertion/removal sequences produced <4% of the aerosol compared with a single cough (p < 0.001). A transient aerosol increase was recorded during one complicated supraglottic airway insertion (which initially failed to provide a patent airway). Detailed analysis of this event showed an atypical particle size distribution and we subsequently identified multiple sources of nonrespiratory aerosols that may be produced during airway management and can be considered as artefacts. These findings demonstrate supraglottic airway insertion/removal generates no more bio-aerosol than breathing and far less than a cough. This should inform the design of infection prevention strategies for anaesthetists and operating theatre staff caring for patients managed with supraglottic airways.
Echocardiography can be used to make accurate hemodynamic measurements; however, training is required. Further studies are needed to validate these methods in the management of critically ill patients.
BackgroundRisk of aerosolisation of SARS-CoV-2 directly informs organisation of acute healthcare and PPE guidance. Continuous positive airways pressure (CPAP) and high-flow nasal oxygen (HFNO) are widely used modes of oxygen delivery and respiratory support for patients with severe COVID-19, with both considered as high risk aerosol generating procedures. However, there are limited high quality experimental data characterising aerosolisation during oxygen delivery and respiratory support.MethodsHealthy volunteers were recruited to breathe, speak, and cough in ultra-clean, laminar flow theatres followed by using oxygen and respiratory support systems. Aerosol emission was measured using two discrete methodologies, simultaneously. Hospitalised patients with COVID-19 were also recruited and had aerosol emissions measured during breathing, speaking, and coughing.FindingsIn healthy volunteers (n = 25 subjects; 531 measures), CPAP (with exhalation port filter) produced less aerosols than breathing, speaking and coughing (even with large >50L/m facemask leaks). HFNO did emit aerosols, but the majority of these particles were generated from the HFNO machine, not the patient. HFNO-generated particles were small (<1μm), passing from the machine through the patient and to the detector without coalescence with respiratory aerosol, thereby unlikely to carry viral particles. Coughing was associated with the highest aerosol emissions with a peak concentration at least 10 times greater the mean concentration generated from speaking or breathing. Hospitalised patients with COVID-19 (n = 8 subjects; 56 measures) had similar size distributions to healthy volunteers.InterpretationIn healthy volunteers, CPAP is associated with less aerosol emission than breathing, speaking or coughing. Aerosol emission from the respiratory tract does not appear to be increased by HFNO. Although direct comparisons are complex, cough appears to generate significant aerosols in a size range compatible with airborne transmission of SARS-CoV-2. As a consequence, the risk of SARS-CoV-2 aerosolisation is likely to be high in all areas where patients with Covid-19 are coughing. Guidance on personal protective equipment policy should reflect these updated risks.FundingNIHR-UKRI Rapid COVID call (COV003), Wellcome Trust GW4-CAT Doctoral Training Scheme (FH), MRC CARP Fellowship(JD, MR/T005114/1). Natural Environment Research Council grant (BB, NE/P018459/1)Research in contextEvidence before this studyPubMed was searched from inception until 10/1/21 using the terms ‘aerosol’, and variations of ‘non-invasive positive pressure ventilation’ and ‘high-flow nasal oxygen therapy’. Studies were included if they measured aerosol generated from volunteers or patients receiving non-invasive positive pressure ventilation (NIV) or high flow nasal oxygen therapy (HFNO), or provided experimental evidence on a simulated human setting. One study was identified (Gaeckle et al, 2020) which measured aerosol emission with one methodology (APS) but was limited by high background concentration of aerosol and a low number of participants (n = 10).Added value of this studyThis study used multiple methodologies to measure aerosol emission from the respiratory tract before and during CPAP and high-flow nasal oxygen, in an ultra-clean, laminar flow theatre with near-zero background aerosol and recruited patients with COVID-19 to ensure similar aerosol distributions. We conclude that there is negligible aerosol generation with CPAP, that aerosol emission from HFNO is from the machine and not the patient, coughing emits aerosols consistent with airborne transmission of SARS CoV2 and that healthy volunteers are a reasonable proxy for COVID-19 patients.Implications of all the available evidenceCPAP and HFNO should not be considered high risk aerosol generating procedures, based on our study and that of Gaeckle et al. Recorded aerosol emission from HFNO stems from the machine. Cough remains a significant aerosol risk. PPE guidance should be updated to ensure medical staff are protected with appropriate PPE in situations when patients with suspected or proven COVID-19 are likely to cough.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.