PGS after open AAA repair occurs more frequently than previously reported. Complications requiring intervention can occur in up to 20% of patients with PGS. A variety of treatment modalities can be used to deal with the complications. Earlier CT surveillance is advised after open AAA repair with a PTFE graft if symptoms are suggestive of PGS development.
The closure of multiple ventricular septal defects remains a surgical challenge. Mortality and morbidity are high. Left ventricular incision and multiple patches or stitches impair septal motion and function. We searched for a method that would cause minimal left ventricular and septal dysfunction. The use of fibrin seal for closing ventricular septal defects was considered. The method was first tested in animals so as to assess the internal resistance of the fibrin seal to stretching and fragmentation in addition to its adhesiveness and hence the absence of left-to-right embolization of the fibrin seal clot and the long-term success of the ventricular septal defect closure further to complete resorption of the ventricular septal defect clot. This experimental work was very satisfactory. Between April 1986 and September 1991, 15 children were operated on with the use of this technique. The overall hospital mortality rate was 6 %. There were no reoperations for residual ventricular septal defects. AU the long-term survivors (n = 13) were in exceUent clinical condition with no or trivial residual shunt attested by color flow mapping investigation. This experimental and clinical experience suggests that satisfactory results can be achieved with the use of fibrin seal for the closure of multiple muscular ventricular septal defects.
Background: Endovascular rescue of failed infrarenal repair (EVAR) has emerged as an attractive option to stent graft explantation. The procedure, however, is underutilized due to limited devices accessibility and the challenges associated with their implantation in this patient population. The purpose of this study was to report our outcomes and discuss our approach to rescuing previously failed infrarenal endovascular aneurysm repairs (EVAR) with fenestrated/ branched endografts (f/b-EVAR). Methods: A retrospective analysis of prospectively collected data of consecutive patients with failed EVAR rescued with f/ b-EVAR at our institution from November 2013 to March 2019 was conducted. The study primary end point was technical success; defined as the implantation of the device with no type I a/b or type III endoleak or conversion to open repair. Secondary endpoints included major adverse events (MAEs), graft patency and reintervention rates. Results: During this time, 202 patients with complex aortic aneurysms were treated with f/b-EVAR. Of these, 19 patients (Male: 17, mean age 79 ± 7 years) underwent repair for failed EVAR. The median time from failed repair to f/b-EVAR was 48 (30, 60) months. Treatment failure was attributed to stent graft migration in 9 (47.4%) patients, disease progression in 5 (26.3%), short initial neck in 3 (15.8%) and unable to be determined in 2 (10.5%). Three patients were treated urgently with surgeon modified stent graft. Technical success was achieved in 18 patients (95%), including two who had undergone emergent repair for rupture. Seventy-two targeted vessels (97.3%) were successfully incorporated. Sixteen (84.2%) patients required a thoracoabdominal repair to achieve a durable seal. Major adverse events (MAEs) occurred in 3 patients (15.7%) including paralysis and death in one (5.3%), compartment syndrome and temporary dialysis in another and laparotomy with snorkeling of one renal and bypass of the other in the third patient. Median (IQR) hospital length of stay was 3 (2, 4) days. Late reintervention, primary target vessel patency and primary assisted patency rates were 5.3%, 98.6% and 100%, respectively. Conclusion: Implantation of f/b-EVAR in patients with failed previous EVAR is a challenging undertaking that can be performed safely with a high technical success and low reintervention rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.