Abstract. As dental caries is one of the most common diseases, the early and noninvasive detection of carious lesions plays an important role in public health care. Optical coherence tomography (OCT) with its ability of depth-resolved, high-resolution, noninvasive, fast imaging has been previously recognized as a promising tool in dentistry. Additionally, polarization sensitive imaging provides quantitative measures on the birefringent tissue properties and can be utilized for imaging dental tissue, especially enamel and dentin. By imaging three exemplary tooth samples ex vivo with proximal white spot, brown spot, and cavity, we show that the combination of polarization sensitive OCT and the degree of polarization uniformity (DOPU) algorithm is a promising approach for the detection of proximal carious lesions due to the depolarization contrast of demineralized tissue. Furthermore, we investigate different sizes of the DOPU evaluation kernel on the resulting contrast and conclude a suitable value for this application. We propose that DOPU provides an easy to interpret image representation and appropriate contrast for possible future screening applications in early caries diagnostics. © The Authors.Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
To date, there is still a lack of reliable imaging modalities to improve the quality of consultation, diagnostic and medical examinations of the oral mucosa in dentistry. Even though, optical technologies have become an important element for the detection and treatment of different diseases of soft tissue, for the case of oral screenings the evidence of the benefit in comparison to conventional histopathology is mostly still pending. One promising optical technology for oral diagnostics is optical coherence tomography (OCT). To prove the potential of OCT, even the amount of freely accessible OCT data is not sufficient to describe the variance of healthy human oral soft tissue in vivo. In order to remedy this deficiency, the present study provides in vivo OCT cross sections of the human oral mucosa of the anterior and posterior oral cavity as well as the oropharynx of 47 adult volunteers. A collection of representative OCT cross sections forms the basis for a randomized blinded image analysis by means of seven criteria to assess the main features of the superficial layers of the human oral mucosa and to determine its correlation to regional features known from hematoxylin and eosin (HE) stained histology.
An endoscopic optical coherence tomography (OCT) system with a wide field-of-view of 8 mm is presented, which combines the image capability of endoscopic imaging at the middle ear with the advantages of functional OCT imaging, allowing a morphological and functional assessment of the human tympanic membrane. The endoscopic tube has a diameter of 3.5 mm and contains gradient-index optics for simultaneous forward-viewing OCT and video endoscopy. The endoscope allows the three-dimensional visualization of nearly the entire tympanic membrane. In addition, the oscillation of the tympanic membrane is measured spatially resolved and in the frequency range between 500 Hz and 5 kHz with 125 Hz resolution, which is realized by phase-resolved Doppler OCT imaging during acoustical excitation with chirp signals. The applicability of the OCT system is demonstrated in vivo. Due to the fast image acquisition, structural and functional measurements are only slightly affected by motion artifacts.
One of the key challenges in osteochondral tissue engineering is to define specified zones with varying material properties, cell types and biochemical factors supporting locally adjusted differentiation into the osteogenic and chondrogenic lineage, respectively. Herein, extrusion-based core-shell bioprinting is introduced as a potent tool allowing a spatially defined delivery of cell types and differentiation factors TGF-β3 and BMP-2 in separated compartments of hydrogel strands, and, therefore, a local supply of matching factors for chondrocytes and osteoblasts. Ink development was based on blends of alginate and methylcellulose, in combination with varying concentrations of the nanoclay Laponite whose high affinity binding capacity for various molecules was exploited. Release kinetics of model molecules was successfully tuned by Laponite addition. Core-shell bioprinting was proven to generate well-oriented compartments within one strand as monitored by optical coherence tomography in a non-invasive manner. Chondrocytes and osteoblasts were applied each in the shell while the respective differentiation factors (TGF-β3, BMP-2) were provided by a Laponite-supported core serving as central factor depot within the strand, allowing directed differentiation of cells in close contact to the core. Experiments with bi-zonal constructs, comprising an osteogenic and a chondrogenic zone, revealed that the local delivery of the factors from the core reduces effects of these factors on the cells in the other scaffold zone. These observations prove the general suitability of the suggested system for co-differentiation of different cell types within a zonal construct.
The common way to diagnose hard and soft tissue irregularities in the oral cavity is initially the visual inspection by an experienced dentist followed by further medical examinations, such as radiological imaging and/or histopathological investigation. For the diagnosis of oral hard and soft tissues, the detection of early transformations is mostly hampered by poor visual access, low specificity of the diagnosis techniques, and/or limited feasibility of frequent screenings. Therefore, optical noninvasive diagnosis of oral tissue is promising to improve the accuracy of oral screening. Considering this demand, a rigid handheld endoscopic scanner was developed for optical coherence tomography (OCT). The novelty is the usage of a commercially near-infrared endoscope with fitting optics in combination with an established spectral-domain OCT system of our workgroup. By reaching a high spatial resolution, in vivo images of anterior and especially posterior dental and mucosal tissues were obtained from the oral cavity of two volunteers. The convincing image quality of the endoscopic OCT device is particularly obvious for the imaging of different regions of the human soft palate with highly scattering fibrous layer and capillary network within the lamina propria.
Objective: After tympanoplasty, it is often challenging to differentiate between different causes of a remaining air bone gap (ABG). Optical coherence tomography (OCT) offers a new approach for combined morphologic and functional measurements of the tympanic membrane and adjacent parts of the middle ear. Thus, it provides valuable diagnostic information in patients with a reduced sound transfer after middle ear surgery. Patient and intervention: A patient with history of tympanoplasty and a persistent ABG was investigated with endoscopic OCT before revision surgery. Main Outcome Measures: The oscillation behavior and the thickness of the reconstructed tympanic membrane was determined. The oscillation amplitudes of the inserted prosthesis were compared to a finite element model simulation and to the clinical findings and the audiometric data of the patient. Results: OCT measurements showed a reduced oscillation amplitude of the prosthesis while revealing an aerated middle ear and good coupling of the prosthesis. Transfer loss measured by OCT showed a similar progression as the ABG measured by pure-tone audiometry with a mean divergence of 4.45 dB. Conclusion: Endoscopic OCT is a promising tool for the evaluation of tympanoplasty outcome. It supports established otologic diagnostics and can help differentiating between different causes of conductional hearing loss.
This study presents a highly miniaturized, handheld probe developed for rapid assessment of soft tissue using optical coherence tomography (OCT). OCT is a non-invasive optical technology capable of visualizing the sub-surface structural changes that occur in soft tissue disease such as oral lichen planus. However, usage of OCT in the oral cavity has been limited, as the requirements for high-quality optical scanning have often resulted in probes that are heavy, unwieldy and clinically impractical. In this paper, we present a novel probe that combines an all-fiber optical design with a light-weight magnetic scanning mechanism to provide easy access to the oral cavity. The resulting probe is approximately the size of a pen (10 mm × 140 mm) and weighs only 10 grams. To demonstrate the feasibility and high image quality achieved with the probe, imaging is performed on the buccal mucosa and alveolar mucosa during routine clinical assessment of six patients diagnosed with oral lichen planus. Results show the loss of normal tissue structure within the lesion, and contrast this with the clear delineation of tissue layers in adjacent inconspicuous regions. The results also demonstrate the ability of the probe to acquire a three-dimensional data volume by manually sweeping across the surface of the mucosa. The findings of this study show the feasibility of using a small, lightweight probe to identify pathological features in oral soft tissue.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.