High-resolution photoinduced transient spectroscopy and the modulated photocurrent technique are compared in terms of possible application to the investigation of defect levels in semi-insulating monocrystalline materials. After a description of the theoretical and experimental aspects, the advantages, drawbacks and limitations of each method are discussed. The two techniques complement each other and their potentialities are exemplified by the measurements of trap parameters in the same samples of semi-insulating Cr-doped and undoped GaAs. From these results we deduce a possible model for the properties of the Cr defect in GaAs.
The paper presents a study of the performance of some selected UV detectors. Unlike many similar works, the obtained data refer to commercial photodiodes (not only to detector materials). The main task of the research was to determine the influence of the operating temperature and annealing on the detector spectral responsiveness. A comparison of the results obtained for the photodiodes made of GaN and SiC was also performed. Although both kinds of detectors can work at high temperatures for a long time, some modification of their properties was observed. However, for GaN and SiC photodiodes, this modification has a substantially different nature. It is very important for some applications, e.g. fire alarms and a military equipment.
The technique of low frequency noise vs temperature is a powerful tool for study of deep level impurities in semiconductors materials. The physical parameters of the deep level defects are possible to identify from noise data. Measurement system to measure low noise spectra in frequency range from 0.01 Hz to 102 kHz at temperature from 77 K to 350 K has described.
Ultraviolet (UV) semiconductor detectors are mainly made of materials with wide energy gap, i.e., of AlGaN, GaP, SiC, and diamond. The article describes methodology of measurements of characteristics of low-frequency noises of UV detectors and presents the developed measuring system. Basing on analysis of noise characteristics of detectors, an optimal working point of detector can be determined. The results of measurements of noise characteristics of UV detectors made of AlGaN are shown. The measurements have been carried out in wide range of temperatures for several values of a detector supply voltage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.