We introduce a redox-active iron complex, Fe-PyC3A, as a biochemically responsive MRI contrast agent. Switching between Fe 3+-PyC3A and Fe 2+-PyC3A yields a full order of magnitude relaxivity change that is field-independent between 1.4 and 11.7 T. The oxidation of Fe 2+-PyC3A to Fe 3+-PyC3A by hydrogen peroxide is very rapid, and we capitalized on this behavior for the molecular imaging of acute inflammation, which is characterized by elevated levels of reactive oxygen species. Injection of Fe 2+-PyC3A generates strong, selective contrast enhancement of inflamed pancreatic tissue in a mouse model (caerulein/LPS model). No significant signal enhancement is observed in normal pancreatic tissue (saline-treated mice). Importantly, signal enhancement of the inflamed pancreas correlates strongly and significantly with ex vivo quantitation of the pro-inflammatory biomarker myeloperoxidase. This is the first example of using metal ion redox for the MR imaging of pathologic change in vivo. Redox-active Fe 3+/2+ complexes represent a new design paradigm for biochemically responsive MRI contrast agents.
Gd-based MRI contrast agents (GBCAs) have come under intense regulatory scrutiny due to concerns of Gd retention and delayed toxicity. Three GBCAs comprising acyclic Gd chelates, the class of GBCA most prone to Gd release, are no longer marketed in Europe. Of particular concern are the acyclic chelates that remain available for liver scans, where there is an unmet diagnostic need and no replacement technology. To address this concern, we evaluated our previously reported Mn-based MRI contrast agent, Mn-PyC3A, and nine newly synthesized derivatives as liver specific MRI contrast agents. Within this focused library the transient liver uptake and rate of blood clearance are directly correlated with log P. The complex Mn-PyC3A-3-OBn emerged as the lead candidate due to a combination of high relaxivity, rapid blood clearance, and avid hepatocellular uptake. Mn-PyC3A-3-OBn rendered liver tumors conspicuously hypo-intense in a murine model and is wholly eliminated within 24 h of injection.
Objectives: The goals of this study were to compare the efficacy of the new manganese-based magnetic resonance imaging (MRI) contrast agent Mn-PyC3A to the commercial gadolinium-based agents Gd-DOTA and to Gd-EOB-DTPA to detect tumors in murine models of breast cancer and metastatic liver disease, respectively, and to quantify the fractional excretion and elimination of Mn-PyC3A in rats. Methods: T1-weighted contrast-enhanced MRI with 0.1 mmol/kg Mn-PyC3A was compared with 0.1 mmol/kg Gd-DOTA in a breast cancer mouse model (n = 8) and to 0.025 mmol/kg Gd-EOB-DTPA in a liver metastasis mouse model (n = 6). The fractional excretion, 1-day biodistribution, and 7-day biodistribution in rats after injection of 2.0 mmol/kg [ 52 Mn]Mn-PyC3A or Gd-DOTA were quantified by 52 Mn gamma counting or Gd elemental analysis. Imaging data were compared with a paired t test; biodistribution data were compared with an unpaired t test. Results: The postinjection-preinjection increases in tumor-to-muscle contrastto-noise ratio (ΔCNR) 3 minutes after injection of Mn-PyC3A and Gd-DOTA (mean ± standard deviation) were 17 ± 3.8 and 20 ± 4.4, respectively (P = 0.34). Liver-to-tumor ΔCNR values at 8 minutes postinjection of Mn-PyC3A and Gd-EOB-DTPAwere 28 ± 9.0 and 48 ± 23, respectively (P = 0.11). Mn-PyC3A is eliminated with 85% into the urine and 15% into the feces after administration to rats. The percentage of the injected doses (%ID) of Mn and Gd recovered in tissues after 1 day were 0.32 ± 0.12 and 0.57 ± 0.12, respectively (P = 0.0030), and after 7 days were 0.058 ± 0.051 and 0.19 ± 0.052, respectively (P < 0.0001). Conclusions: Mn-PyC3A provides comparable tumor contrast enhancement to Gd-DOTA in a mouse breast cancer model and is more completely eliminated than Gd-DOTA; partial hepatobiliary elimination of Mn-PyC3A enables conspicuous delayed phase visualization of liver metastases.
We introduce a new biochemically responsive Mn-based MRI contrast agent that provides a 9-fold change in relaxivity via switching between the Mn3+ and Mn2+ oxidation states. Interchange between oxidation states is promoted by a “Janus” ligand that isomerizes between binding modes that favor Mn3+ or Mn2+. It is the only ligand that supports stable complexes of Mn3+ and Mn2+ in biological milieu. Rapid interconversion between oxidation states is mediated by peroxidase activity (oxidation) and L-cysteine (reduction). This Janus system provides a new paradigm for the design of biochemically responsive MRI contrast agents.
A paraxial resonance equation is derived. This gives the mirror separation as a function of the radii of curvature of the mirrors and an integer N which is the number of return transits necessary to form a closed path of rays. Differentiating the paraxial resonance equation gives a formula for the relative mode density as a function of mirror separation. It is shown that the output power from a laser incorporating solid mirrors is inversely proportional to the mode density. In the case of hole coupling, the output power follows the same general profile but dips in power occur at the mirror separations corresponding to the resonance configurations of modes characterized by low values of N. Further confirmation of the paraxial resonance equation is obtained from passive resonators in which conic interference fringes and sudden increases in transmitted intensity are found to occur at the predicted mirror separations for low values of N corresponding to mode-degenerate configurations. The positions of the vertices of the ray traces are found to correspond to the patterns of discrete spots which are obtained in the output of a CO(2) laser incorporating Brewster angle windows and a solid germanium mirror. The laser configurations which give maximum output power are plotted as a cliff of constant height above the g(1)g(2) plane of the stability diagram, where g(1) and g(2) are the configuration coordinates. The relative merits of all possible cavity configurations having one mirror in common are shown as a set of equipower contours, and the hyperbolic curves of constant N are also superimposed on the stability diagram. The advantages of simplicity and directness in using the ray model are made clear.
Purpose To evaluate the biodistribution, metabolism, and pharmacokinetics of a new type I collagen-targeted magnetic resonance (MR) probe, CM-101, and to assess its ability to help quantify liver fibrosis in animal models. Materials and Methods Biodistribution, pharmacokinetics, and stability of CM-101 in rats were measured with mass spectrometry. Bile duct-ligated (BDL) and sham-treated rats were imaged 19 days after the procedure by using a 1.5-T clinical MR imaging unit. Mice were treated with carbon tetrachloride (CCl) or with vehicle two times a week for 10 weeks and were imaged with a 7.0-T preclinical MR imaging unit at baseline and 1 week after the last CCl treatment. Animals were imaged before and after injection of 10 µmol/kg CM-101. Change in contrast-to-noise ratio (ΔCNR) between liver and muscle tissue after CM-101 injection was used to quantify liver fibrosis. Liver tissue was analyzed for Sirius Red staining and hydroxyproline content. The institutional subcommittee for research animal care approved all in vivo procedures. Results CM-101 demonstrated rapid blood clearance (half-life = 6.8 minutes ± 2.4) and predominately renal elimination in rats. Biodistribution showed low tissue gadolinium levels at 24 hours (<3.9% injected dose [ID]/g ± 0.6) and 10-fold lower levels at 14 days (<0.33% ID/g ± 12) after CM-101 injection with negligible accumulation in bone (0.07% ID/g ± 0.02 and 0.010% ID/g ± 0.004 at 1 and 14 days, respectively). ΔCNR was significantly (P < .001) higher in BDL rats (13.6 ± 3.2) than in sham-treated rats (5.7 ± 4.2) and in the CCl-treated mice (18.3 ± 6.5) compared with baseline values (5.2 ± 1.0). Conclusion CM-101 demonstrated fast blood clearance and whole-body elimination, negligible accumulation of gadolinium in bone or tissue, and robust detection of fibrosis in rat BDL and mouse CCl models of liver fibrosis. RSNA, 2017 Online supplemental material is available for this article.
Objectives Mn-PyC3A is an experimental manganese (Mn)-based extracellular fluid magnetic resonance imaging (MRI) contrast agent that is being evaluated as a direct replacement for clinical gadolinium (Gd)-based contrast agents. The goals of this study were to use simultaneous positron emission tomography (PET)–MRI to (1) compare the whole-body pharmacokinetics, biodistribution, and elimination of Mn-PyC3A with the liver-specific contrast agent mangafodipir (Mn-DPDP), (2) determine the pharmacokinetics and fractional excretion of Mn-PyC3A in a rat model of renal impairment, and (3) compare whole-body elimination of Mn-PyC3A to gadoterate (Gd-DOTA) in a rat model of renal impairment. Methods Mn-PyC3A and Mn-DPDP were radiolabeled with the positron emitting isotope Mn-52 via Mn2+ exchange with 52MnCl2. Dynamic simultaneous PET-MRI was used to measure whole-body pharmacokinetics and biodistribution of Mn-52 immediately and out to 7 days after an intravenous 0.2 mmol/kg dose of [52Mn]Mn-PyC3A to normal or to 5/6 nephrectomy rats or a 0.01 mmol/kg dose of [52Mn]Mn-DPDP to normal rats. The fractional excretion and 1- and 7-day biodistribution in rats after the injection of 2.0 mmol/kg [52Mn]Mn-PyC3A (n = 11 per time point) or 2.0 mmol/kg Gd-DOTA (n = 8 per time point) were quantified by gamma counting or Gd elemental analysis, respectively. Comparisons of Mn-PyC3A pharmacokinetics and in vivo biodistribution in normal and 5/6 nephrectomy rats and comparisons of ex vivo Mn versus Gd biodistribution data in 5/6 nephrectomy were made with an unpaired t test. Results Dynamic PET-MRI data demonstrate that both [52Mn]Mn-PyC3A and [52Mn]Mn-DPDP were eliminated by mixed renal and hepatobiliary elimination but that a greater fraction of [52Mn]Mn-PyC3A was eliminated by renal filtration. Whole-body PET images show that Mn-52 from [52Mn]Mn-PyC3A was efficiently eliminated from the body, whereas Mn-52 from [52Mn]Mn-DPDP was retained throughout the body. The blood elimination half-life of [52Mn]Mn-PyC3A in normal and 5/6 nephrectomy rats was 13 ± 3.5 minutes and 23 ± 12 minutes, respectively (P = 0.083). Area under the curve between 0 and 60 minutes postinjection (AUC0–60) in the bladder of normal and 5/6 nephrectomy rats was 2600 ± 1700 %ID/cc*min and 750 ± 180 %ID/cc*min, respectively (P = 0.024), whereas AUC0–60 in the liver of normal and 5/6 nephrectomy rats was 33 ± 13 %ID/cc*min and 71 ± 16 %ID/cc*min, respectively (P = 0.011), indicating increased hepatobiliary elimination in 5/6 nephrectomy rats. The %IDs of Mn from [52Mn]Mn-PyC3A and Gd from Gd-DOTA recovered from 5/6 nephrectomy rats 1 day after injection were 2.0 ± 1.1 and 1.3 ± 0.34, respectively (P = 0.10) and 7 days after injection were 0.14 ± 0.11 and 0.41 ± 0.24, respectively (P = 0.0041). Conclusions Mn-PyC3A has different pharmacokinetics and is more efficiently eliminated than Mn-DPDP in normal rats. Mn-PyC3A is efficiently eliminated from both normal and 5/6 nephrectomy rats, with increased fractional hepatobiliary excretion from 5/6 nephrectomy rats. Mn-PyC3A is more completely eliminated than Gd-DOTA from 5/6 nephrectomy rats after 7 days.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.