Screening for chlamydia in women is widely recommended. We evaluated the performance of two nucleic acid amplification tests for detecting Chlamydia trachomatis in self-collected vulvovaginal-swab and first-catch urine specimens from women in a community setting and a strategy for optimizing the sensitivity of an amplified enzyme immunoassay on vulvovaginal-swab specimens. We tested 2,745 paired vulvovaginal-swab and urine specimens by PCR (Roche Cobas) or strand displacement amplification (SDA; Becton Dickinson). There were 146 women infected with chlamydia. The assays detected 97.3% (95% confidence interval [CI], 93.1 to 99.2%) of infected patients with vulvovaginal-swab specimens and 91.8% (86.1 to 95.7%) with urine specimens. We tested 2,749 vulvovaginal-swab specimens with both a nucleic acid amplification test and a polymer conjugateenhanced enzyme immunoassay with negative-gray-zone testing. The relative sensitivities obtained after retesting specimens in the negative gray zone were 74.3% (95% CI, 62.8 to 83.8%) with PCR and 58.3% (95% CI, 46.1 to 69.8%) with SDA. In community settings, both vulvovaginal-swab and first-catch urine specimens from women are suitable substrates for nucleic acid amplification tests, but enzyme immunoassays, even after negative-gray-zone testing, should not be used in screening programs.
Four fluorescent antibody reagents were evaluated for their suitability for the identification of adenovirus isolates by immunofluorescence. The antibodies used in the reagents consist of monoclonal antibodies against adenovirus type 3 (Ad3), Ad4, Ad8, and adenoviruses of subgroup C (Ad1,2,5,6), serotypes known to occur in outbreaks of disease. Most of the monoclonal antibodies employed were reactive against type-specific antigens found on the hexon protein. Reagents employing two noncompeting anti-hexon antibodies were more sensitive than reagents prepared with only one monoclonal antibody, although both types of reagents exhibited a high degree of specificity. Five hundred and seventeen adenovirus isolates (359 of which had previously been typed by other methods) and 46 nonadenovirus isolates were examined with all four type-specific reagents in parallel with an adenovirus group-specific reagent. The results indicate that direct typing of adenovirus isolates is feasible, leading to significant savings in time compared to other typing methods and should contribute to the management of certain adenovirus infections, particularly during outbreaks.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.