The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN system consists of a plastic chamber that is conically cylindrical in shape and about 0.5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited decay products of radon. Kodak has a spectrometric character--the tracks are visualized only for alphas with energies between 1 and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of (218)Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleotherapy.
A national radon survey is still lacking for Greece. Some groups have carried out several more or less local or extended radon surveys and valuable experience has been gained. After the first preliminary survey carried out by our group, where 500 Kodak LR-115 etched track detectors were placed in Greek schools and dwellings for one year, indoor radon measurements were continued by placing the same number of detectors in a restricted area, covering the city of Kalamata (a medium size city with 60,000 inhabitants), situated in the south of Peloponnese. Although Kalamata was not of special radon interest, the local authorities insisted on knowing for their citizens' sake the level of this natural radiation. At first, the intention was to use a different method of organisation and distribution of the etched-track detectors from the previous one, attempting mainly to acquire more reliable results and to collect as many detectors as possible. Secondly, it was of great importance to test the statistics of the indoor radon concentrations for a rather small area, and thirdly, to estimate independently the annual absorbed dose by children, taking into account radon concentrations measured both in their home and at school. The set of detectors' readings (about 370), revealed, in general, lower values for Kalamata, compared to the ones found in the preliminary radon survey in Greece and almost all concentrations were found to be below the NRPB action level (200 Bq.m-3).
The radon issue has been known worldwide for dozens of years. Many scientific (ICRP Publication No. 137), technical (ICRU Report No. 88), and legislative (Council Directive 2013/59/EURATOM (EU-BSS)) documents have been published in the last decade. More and more attention is being paid to precise quantification to determine the concentration and consequent effects of various pollutants on human health worldwide. The quality of measurement and the variety of measurement techniques increase the need to unify measurement procedures and metrology continuity. Countries around the world are beginning to unify metrological procedures for determining different quantities based on international recommendations and standards. Not only for these reasons, it became more actual a need for more accurate radon activity concentration measurement and radon metrology unification. This paper summarizes the main remarks and technical aspects to the historical development of radon metrology.
The Authorized Metrological Centre (AMS) working by SUJCHBO (National Institute for Nuclear, Chemical and Biological Protection) ensures for the Czech Republic the metrological traceability for devices that measure the radon concentration and the energy equivalent radon concentration connected with the radon decay products (RnDP). The evaluation and the calibration of measuring devices for radon and RnDP require the stable conditions (first of all radon and the RnDP concentrations). The new AMS radon-aerosol chamber in Kamenná consists of the walk-in testing chamber with a volume of 10 m(3) and of the handling box with a volume of 0.3 m(3). The design of the chamber allows measurement and a control of environmental parameters such as the temperature, the pressure of air inside and outside of the chamber, the relative humidity of air, the concentration and the size distribution of aerosol particles and the air velocity.
Measurements of activity concentration of radon gas and radon decay products were carried out in several workplaces including schools, radium spas, swimming pools, water treatment plants, caves and former mines. Based on these measurements, annual effective doses to workers were estimated and values of the equilibrium factor, F, were calculated. This paper describes the different approaches used to estimate the annual effective dose based on the dose coefficients recommended by the International Commission on Radiological Protection. Using the measured F values as opposed to the default F value of 0.4 changed the doses by about 5–95% depending mainly upon the ventilation conditions of the workplace.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.