Purpose:
Screening guidelines for retinopathy of prematurity (ROP) are updated frequently to help clinicians identify infants at risk of type 1 ROP. This study aims to evaluate the accuracy of three different predictive algorithms—WINROP, ROPScore, and CO-ROP—in detecting ROP in preterm infants in a developing country.
Methods:
This retrospective study was conducted on 386 preterm infants from two centers between 2015 and 2021. Neonates with gestational age ≤30 weeks and/or birth weight ≤1500 g who underwent ROP screening were included.
Results:
One hundred twenty-three neonates (31.9%) developed ROP. The sensitivity to identify type 1 ROP was as follows: WINROP, 100%; ROPScore, 100%; and CO-ROP, 92.3%. The specificity was 28% for WINROP, 1.4% for ROPScore, and 19.3% for CO-ROP. CO-ROP missed two neonates with type 1 ROP. WINROP provided the best performance for type 1 ROP with an area under the curve score at 0.61.
Conclusion:
The sensitivity was at 100% for WINROP and ROPScore for type 1 ROP; however, specificity was quite low for both algorithms. Highly specific algorithms tailored to our population may serve as a useful adjunctive tool to detect preterm infants at risk of sight-threatening ROP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.