A double-hyperfragment event has been found in a hybrid-emulsion experiment. It is identified uniquely as the sequential decay of ( 6)(LambdaLambda)He emitted from a Xi(-) hyperon nuclear capture at rest. The mass of ( 6)(LambdaLambda)He and the Lambda-Lambda interaction energy DeltaB(LambdaLambda) have been measured for the first time devoid of the ambiguities due to the possibilities of excited states. The value of DeltaB(LambdaLambda) is 1.01+/-0.20(+0.18)(-0.11) MeV. This demonstrates that the Lambda-Lambda interaction is weakly attractive.
The direct comparison of the emission characteristics of an extreme ultraviolet (EUV) light between the CO2 and the Nd:YAG laser-produced plasmas (LPP) with a solid tin target is reported. In the case of the Nd:YAG LPP, the conversion efficiency (C.E.) peaked at a laser intensity of about 5×1010W∕cm2 and decreased at higher laser intensity. In the case of the CO2 LPP, the C.E. monotonically increased up to 2×1010W∕cm2, where the C.E. is comparable to the maximum C.E. of the Nd:YAG LPP. The spectral efficiency of the Nd:YAG LPP within the 2% bandwidth around 13.5 nm decreased with laser intensity. The corresponding spectral efficiency of the CO2 LPP was almost constant. This observation indicates the potential of the CO2 laser-produced LPP as the EUV light source for the EUV lithographic systems.
BackgroundBoron neutron capture therapy (BNCT) is a cellular-level particle radiation therapy that combines the selective delivery of boron compounds to tumour tissue with neutron irradiation. L-p-Boronophenylalanine (L-BPA) is a boron compound now widely used in clinical situations. Determination of the boron distribution is required for successful BNCT prior to neutron irradiation. Thus, positron emission tomography with [18F]-L-FBPA, an 18F-labelled radiopharmaceutical analogue of L-BPA, was developed. However, several differences between L-BPA and [18F]-L-FBPA have been highlighted, including the different injection doses and administration protocols. The purpose of this study was to clarify the equivalence between L-BPA and [19F]-L-FBPA as alternatives to [18F]-L-FBPA.MethodsSCC-VII was subcutaneously inoculated into the legs of C3H/He mice. The same dose of L-BPA or [19F]-L-FBPA was subcutaneously injected. The time courses of the boron concentrations in blood, tumour tissue, and normal tissue were compared between the groups. Next, we administered the therapeutic dose of L-BPA or the same dose of [19F]-L-FBPA by continuous infusion and compared the effects of the administration protocol on boron accumulation in tissues.ResultsThere were no differences between L-BPA and [19F]-L-FBPA in the transition of boron concentrations in blood, tumour tissue, and normal tissue using the same administration protocol. However, the normal tissue to blood ratio of the boron concentrations in the continuous-infusion group was lower than that in the subcutaneous injection group.ConclusionsNo difference was noted in the time course of the boron concentrations in tumour tissue and normal tissues between L-BPA and [19F]-L-FBPA. However, the administration protocol had effects on the normal tissue to blood ratio of the boron concentration. In estimating the BNCT dose in normal tissue by positron emission tomography (PET), we should consider the possible overestimation of the normal tissue to blood ratio of the boron concentrations derived from the values measured by PET on dose calculation.Electronic supplementary materialThe online version of this article (doi:10.1186/s12885-016-2913-x) contains supplementary material, which is available to authorized users.
Background
Boron neutron capture therapy (BNCT) utilizes tumor-selective particle radiation. This study aimed to assess the safety and efficacy of accelerator-based BNCT (AB-BNCT) using a cyclotron-based neutron generator (BNCT 30) and 10B-boronophenylalanine (SPM-011) in patients with recurrent malignant glioma (MG) (primarily glioblastoma [GB]).
Methods
This multi-institutional, open-label, phase II clinical trial involved 27 recurrent MG cases, including 24 GB cases, who were enrolled from February 2016 to June 2018. The study was conducted using the abovementioned AB-BNCT system, with 500 mg/kg SPM-011 (study code: JG002). The patients were bevacizumab-naïve and had recurrent MG after standard treatment. The primary endpoint was the 1-year survival rate, and the secondary endpoints were overall survival (OS) and progression-free survival (PFS). Results were compared to those of a previous Japanese domestic bevacizumab trial for recurrent GB (JO22506).
Results
The 1-year survival rate and median OS of the recurrent GB cases in this trial were 79.2% (95% CI: 57.0–90.8) and 18.9 months (95% CI: 12.9–not estimable), respectively, whereas those of JO22506 were 34.5% (90% CI: 20.0–49.0) and 10.5 months (95% CI: 8.2–12.4), respectively. The median PFS was 0.9 months (95% CI: 0.8–1.0) by the RANO criteria. The most prominent adverse event was brain edema. Twenty-one of 27 cases were treated with bevacizumab following progressive disease.
Conclusions
AB-BNCT demonstrated acceptable safety and prolonged survival for recurrent MG. AB-BNCT may increase the risk of brain edema due to re-irradiation for recurrent MG; however, this appears to be controlled well with bevacizumab.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.