Microfluidic cell cultures are ideally positioned to become the next generation of in vitro diagnostic tools for biomedical research, where key biological processes such as cell signalling and dynamic cell-to-cell interactions can be reliably analysed under reproducible physiological cell culture conditions. In the last decade, a large number of microfluidic cell analysis systems have been developed for a variety of applications including drug target optimization, drug screening and toxicological testing. More recently, advanced in vitro microfluidic cell culture systems have emerged that are capable of replicating the complex three-dimensional architectures of tissues and organs and thus represent valid biological models for investigating the mechanism and function of human tissue structures, as well as studying the onset and progression of diseases such as cancer. In this review, we present the most important developments in single-cell, 2D and 3D microfluidic cell culture systems for studying cell-to-cell interactions published over the last 6 years, with a focus on cancer research and immunotherapy, vascular models and neuroscience. In addition, the current technological development of microdevices with more advanced physiological cell microenvironments that integrate multiple organ models, namely, the so-called body-, human- and multi-organ-on-a-chip, is reviewed.
Knowledge on the availability of dissolved oxygen inside microfluidic cell culture systems is vital for recreating physiological-relevant microenvironments and for providing reliable and reproducible measurement conditions. It is important to highlight that in vivo cells experience a diverse range of oxygen tensions depending on the resident tissue type, which can also be recreated in vitro using specialized cell culture instruments that regulate external oxygen concentrations. While cell-culture conditions can be readily adjusted using state-of-the-art incubators, the control of physiological-relevant microenvironments within the microfluidic chip, however, requires the integration of oxygen sensors. Although several sensing approaches have been reported to monitor oxygen levels in the presence of cell monolayers, oxygen demands of microfluidic three-dimensional (3D)-cell cultures and spatio-temporal variations of oxygen concentrations inside two-dimensional (2D) and 3D cell culture systems are still largely unknown. To gain a better understanding on available oxygen levels inside organ-on-a-chip systems, we have therefore developed two different microfluidic devices containing embedded sensor arrays to monitor local oxygen levels to investigate (i) oxygen consumption rates of 2D and 3D hydrogel-based cell cultures, (ii) the establishment of oxygen gradients within cell culture chambers, and (iii) influence of microfluidic material (e.g., gas tight vs. gas permeable), surface coatings, cell densities, and medium flow rate on the respiratory activities of four different cell types. We demonstrate how dynamic control of cyclic normoxic-hypoxic cell microenvironments can be readily accomplished using programmable flow profiles employing both gas-impermeable and gas-permeable microfluidic biochips.
Organ-on-a-chip technology offers the potential to recapitulate human physiology by keeping human cells in a precisely controlled and artificial tissue-like microenvironment. The current and potential advantages of organs-on-chips over conventional cell cultures systems and animal models have captured the attention of scientists, clinicians and policymakers as well as advocacy groups in the past few years. Recent advances in tissue engineering and stem cell research are also aiding the development of clinically relevant chip-based organ and diseases models with organ level physiology for drug screening, biomedical research and personalized medicine. Here, the latest advances in organ-on-a-chip technology are reviewed and future clinical applications discussed.
Reengineering functional vascular networks remains an integral part in tissue engineering, since the incorporation of non-perfused tissues results in restricted nutrient supply and limited waste removal. Microfluidic devices are routinely used to mimic both physiological and pathological vascular microenvironments. Current procedures either involve the investigation of growth factor gradients and interstitial flow on endothelial cell sprouting alone or on the heterotypic cell-cell interactions between endothelial and mural cells. However, limited research has been conducted on the influence of flow on co-cultures of these cells. Here, we exploited the ability of microfluidics to create and monitor spatiotemporal gradients to investigate the influence of growth factor supply and elution on vascularization using static as well as indirect and direct flow setups. Co-cultures of human adipose-derived stem/stromal cells and human umbilical vein endothelial cells embedded in fibrin hydrogels were found to be severely affected by diffusion limited growth factor gradients as well as by elution of reciprocal signaling molecules during both static and flow conditions. Static cultures formed pre-vascular networks up to a depth of 4 mm into the construct with subsequent decline due to diffusion limitation. In contrast, indirect flow conditions enhanced endothelial cell sprouting but failed to form vascular networks. Additionally, complete inhibition of pre-vascular network formation was observable for direct application of flow through the hydrogel with decline of endothelial cell viability after seven days. Using finite volume CFD simulations of different sized molecules vital for pre-vascular network formation into and out of the hydrogel constructs, we found that interstitial flow enhances growth factor supply to the cells in the bulk of the chamber but elutes cellular secretome, resulting in truncated, premature vascularization.
Translation of advanced cell-based assays exhibiting a higher degree of automation, miniaturization and integration of complementary sensing functions is mainly limited by the development of industrial-relvant prototypes that can be...
This Article presents an automated, compact, and self-contained system for sensitive quantitative detection of blood biomarkers. A disposable microfluidic chip, prefilled with biomarker-specific reagents and magnetic beads, can be processed fully automatically by a readout platform, enabling an immunoassay-based analysis with a processing time from sample incubation to signal analysis of 20 min. Novel concepts for on-chip vortexing of the magnetic beads and on-chip reagent storage and actuation were developed. A lens-free photodiode readout system represents a cost-efficient approach for detecting the chemiluminescent signal. IL-8 spiked serum samples were measured with a high reproducibility and a limit of detection of 2.05 pg·mL–1. The system was validated with undiluted serum samples collected from trauma patients at the intensive care unit. The developed platform demonstrated good correlation with the clinical reference method, and the clinical trajectory course of IL-8 could be sufficiently followed. With an automated assay approach and an easily adaptable protocol, this portable platform has the potential to be utilized as a universal instrument for analyzing proteins in small sample volumes (<25 μL) in point-of-care settings.
In the past decade a large amount of analysis techniques have been scaled down to the microfluidic level. However, in many cases the necessary sample preparation, such as separation, mixing and concentration, remains to be performed off-chip. This represents a major hurdle for the introduction of miniaturized sample-in/answer-out systems, preventing the exploitation of microfluidic's potential for small, rapid and accurate diagnostic products. New flow engineering methods are required to address this hitherto insufficiently studied aspect. One microfluidic tool that can be used to miniaturize and integrate sample preparation procedures are microvortices. They have been successfully applied as microcentrifuges, mixers, particle separators, to name but a few. In this work, we utilize a novel corner structure at a sudden channel expansion of a microfluidic chip to enhance the formation of a microvortex. For a maximum area of the microvortex, both chip geometry and corner structure were optimized with a computational fluid dynamic (CFD) model. Fluorescent particle trace measurements with the optimized design prove Micromachines 2015, 6 240 that the corner structure increases the size of the vortex. Furthermore, vortices are induced by the corner structure at low flow rates while no recirculation is observed without a corner structure. Finally, successful separation of plasma from human blood was accomplished, demonstrating a potential application for clinical sample preparation. The extracted plasma was characterized by a flow cytometer and compared to plasma obtained from a standard benchtop centrifuge and from chips without a corner structure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.