The strong demand for renewable energy promotes research on novel methods and technologies for energy conversion. Microfluidic systems for energy conversion by streaming current are less known to the public, and the relatively low efficiencies previously obtained seemed to limit the further applications of such systems. Here we report a microdropletbased electrostatic generator operating by an acceleration-deceleration cycle ('ballistic' conversion), and show that this principle enables both high efficiency and compact simple design. Water is accelerated by pumping it through a micropore to form a microjet breaking up into fast-moving charged droplets. Droplet kinetic energy is converted to electrical energy when the charged droplets decelerate in the electrical field that forms between membrane and target. We demonstrate conversion efficiencies of up to 48%, a power density of 160 kW m À 2 and both high-(20 kV) and low-(500 V) voltage operation. Besides offering striking new insights, the device potentially opens up new perspectives for low-cost and robust renewable energy conversion.
The use of high quality semen for artificial insemination in the livestock industry is essential for successful outcome. Insemination using semen with a high number of sperm cells containing morphological defects has a negative impact on fertilization outcome. Therefore, semen with a high number of these abnormal cells is discarded in order to maintain high fertilization potential, resulting in the loss of a large number of morphologically normal sperm cells (up to 70-80% of original sample). A commonly occurring morphological sperm anomaly is the cytoplasmic droplet on the sperm flagella. Currently, no techniques are available to extract morphologically normal sperm cells from rejected samples. Therefore, we aim to develop a microfluidic setup which is able to detect and sort morphologically normal sperm cells label-free and non-invasively. In a proof-of-concept experiment, differential impedance measurements were used to detect the presence of cytoplasmic droplets on sperm flagella, which was quantified by calculating the area under the curve (AUC) of the corresponding impedance peaks. A receiver operating characteristic curve of this electrical analysis method showed the good predictive power of this analysis method (AUC value of 0.85). Furthermore, we developed a label-free cell sorting system using LabVIEW, which is capable of sorting sperm cells based on impedance. In a proof-of-concept experiment, sperm cells and 3 μm beads were sorted label-free and non-invasively using impedance detection and dielectrophoresis sorting. These experiments present our first attempt to perform sperm refinement using microfluidic technology.
We present an electrokinetic label-free biomolecular screening chip (Glass/PDMS) to screen up to 10 samples simultaneously using surface plasmon resonance imaging (iSPR). This approach reduces the duration of an experiment when compared to conventional experimental methods. This new device offers a high degree of parallelization not only for analyte samples, but also for multiplex analyte interactions where up to 90 ligands are immobilized on the sensing surface. The proof of concept has been demonstrated with well-known biomolecular interactant pairs. The new chip can be used for high throughput screening applications and kinetics parameter extraction, simultaneously, of interactant-protein complex formation.
While scanning electrochemical microscopy (SECM) is a powerful technique for non-invasive analysis of cells, SECM-based assays remain scarce and have been mainly limited so far to single cells, which is mostly due to the absence of suitable platform for experimentation on 3D cellular aggregates or microtissues. Here, we report stamping of a Petri dish with a microwell array for large-scale production of microtissues followed by their in situ analysis using SECM. The platform is realized by hot embossing arrays of microwells (200 μm depth; 400 μm diameter) in commercially available Petri dishes, using a PDMS stamp. Microtissues form spontaneously in the microwells, which is demonstrated here using various cell lines (e.g., HeLa, C2C12, HepG2 and MCF-7). Next, the respiratory activity of live HeLa microtissues is assessed by monitoring the oxygen reduction current in constant height mode and at various distances above the platform surface. Typically, at a 40 μm distance from the microtissue, a 30% decrease in the oxygen reduction current is measured, while above 250 μm, no influence of the presence of the microtissues is detected. After exposure to a model drug (50% ethanol), no such changes in oxygen concentration are found at any height in solution, which reflects that microtissues are not viable anymore. This is furthermore confirmed using conventional live/dead fluorescent stains. This live/dead assay demonstrates the capability of the proposed approach combining SECM and microtissue arrays formed in a stamped Petri dish for conducting cellular assays in a non-invasive way on 3D cellular models.
We present a simple electrokinetic lab-on-a-biochip (EKLB) with four microchannels integrated with a surface plasmon resonance imaging (iSPR) label-free biosensor that is operated using a single electrical voltage for the simultaneous transport of reagents in all microchannels without conventional fluidic plumbing. We demonstrate the utility of the simple approach with various biosensing experiments, including single injection kinetics (multiple varied ligand densities and single analyte concentration), one shot kinetics (single ligand densities and multiple varied analyte concentrations), and multi-ligand/multianalyte detection. In all cases, the binding kinetics and affinity were extracted using a conventional 1:1 interaction model. Since the reagent transport is done with a single electrical voltage source, scaling up to hundreds to thousands of simultaneous experiments is straightforward.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.