PurposeTo evaluate optic nerve vascular density using swept source optical coherence tomography angiography (OCTA) in patients with early primary open angle glaucoma (POAG), pre-perimetric glaucoma and normal eyes.MethodsThis is a prospective, observational study including 56 eyes in total and divided into 3 groups; 20 eyes with mild POAG, 20 pre-perimetric glaucoma eyes, and 16 age-matched normal eyes as controls. The optic disc region was imaged by a 1050-nm-wavelength swept-source OCT system (DRI OCT Triton, TOPCON). Vessel density was assessed as the ratio of the area occupied by the vessels in 3 distinct regions: 1) within the optic nerve head; 2) in the 3 mm papillary region around the optic disc; and 3) in the peripapillary region, defined as a 700-μm-wide elliptical annulus around the disc. The potential associations between vessel density and structural, functional measures were analyzed.ResultsThere was a statistically significant difference for the peripapillary vessel density, optic nerve head vessel density, and papillary vessel density among all the groups (p<0.001). Control eyes showed a significant difference for all measured vessel densities compared to glaucomatous eyes (p values from 0.001 to 0.024). There was a statistically significant difference between control and pre-perimetric glaucoma eyes for peripapillary, optic nerve head and papillary vessel density values (p values from 0.001 to 0.007). The optic nerve head vessel density, superior and inferior papillary area vessel density (Pearson r = 0.512, 0.436, 0.523 respectively) were highly correlated with mean overall, superior and inferior RNFL thickness in POAG eyes (p = 0.04, p = 0.02 and p = 0.04 respectively). Multiple linear regression analysis of POAG group showed that optic nerve head vessel density in POAG group was more strongly linked to RNFL thickness than to any other variables.ConclusionsEyes with mild POAG could be differentiated from pre-perimetric glaucoma eyes, which also could be differentiated from normal eyes using OCTA-derived retinal vessel density measurements.
Optical coherence tomography angiography provides high-resolution, noninvasive visualization of the microvasculature of the optic nerve head and peripapillary region. Changes in the microvasculature in this region may prove useful in better characterization of optic neuropathies.
BackgroundTo study the impact of image quality on quantitative measurements and the frequency of segmentation error with optical coherence tomography angiography (OCTA).MethodsSeventeen eyes of 10 healthy individuals were included in this study. OCTA was performed using a swept-source device (Triton, Topcon). Each subject underwent three scanning sessions 1–2 min apart; the first two scans were obtained under standard conditions and for the third session, the image quality index was reduced using application of a topical ointment. En face OCTA images of the retinal vasculature were generated using the default segmentation for the superficial and deep retinal layer (SRL, DRL). Intraclass correlation coefficient (ICC) was used as a measure for repeatability. The frequency of segmentation error, motion artifact, banding artifact and projection artifact was also compared among the three sessions.ResultsThe frequency of segmentation error, and motion artifact was statistically similar between high and low image quality sessions (P = 0.707, and P = 1 respectively). However, the frequency of projection and banding artifact was higher with a lower image quality. The vessel density in the SRL was highly repeatable in the high image quality sessions (ICC = 0.8), however, the repeatability was low, comparing the high and low image quality measurements (ICC = 0.3). In the DRL, the repeatability of the vessel density measurements was fair in the high quality sessions (ICC = 0.6 and ICC = 0.5, with and without automatic artifact removal, respectively) and poor comparing high and low image quality sessions (ICC = 0.3 and ICC = 0.06, with and without automatic artifact removal, respectively).ConclusionsThe frequency of artifacts is higher and the repeatability of the measurements is lower with lower image quality. The impact of image quality index should be always considered in OCTA based quantitative measurements.
Results: Baseline IOP for PG is 24.4 ± 7.7 mmHg and 24.2 ± 7.5 mmHg for POAG (P = 1.0), while baseline number of glaucoma medications was 2.8 ± 1.2 mmHg for PG and 2.8 ± 1.2 mmHg for POAG (P = 1.0). Postoperative IOP values at 12 months were 17.1 ± 5.0 for PG cases and 15.9 ± 4.2 mmHg for POAG cases. Postoperative number of glaucoma medications at 12 month was 2.1 ± 1.4 in PG cases and 2.4 ± 1.3 in POAG cases. There was no statistically significant difference between groups in IOP or number of medications at any time point. Survival rate at 12 months was 92% and 86% in PG and POAG, respectively (P = 0.47). Six PG cases and nine POAG cases required secondary surgery.Conclusion: Trabectome provides similar outcomes to PG patients and POAG patients.
PurposeTo evaluate the performance of the hand-held and table-top autorefractokeratometer in measuring refractive errors by comparing them with cycloplegic retinoscopy.MethodsIncluded in the study were 112 eyes of 112 pediatric patients whose mean age was 6.78 ± 2.61 years (range, 2 to 12 years). The refractive errors of all the eyes were measured with and without cycloplegia using a hand held autorefractokeratometer (Retinomax K-plus 3), table top autorefractokeratometer (Canon RK-F1) and performing cycloplegic retinoscopy. The spherical equivalent, cylindrical axis and keratometer values were statistically compared.ResultsThe mean spherical equivalent obtained from the Retinomax K-plus 3 was significantly less hyperopic than that of Canon RK-F1 (p = 0.004) before cycloplegia. When the Bland Altman analysis was performed in comparisons of spherical equivalent values measured with the Retinomax K-plus 3, Canon RK-F1 and cycloplegic retinoscopy, it was seen that almost all of the differences between the measurements remained within the range of ±2 standard deviation. Good agreement was found between Retinomax K-plus 3 and Canon RK-F1 for the Jackson cross-cylinder values at axis 0° and 45°; keratometer values respectively.ConclusionsThe refractive error components were highly correlated between the two instruments and cycloplegic retinoscopy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.