ABSTRACT.-Terzariol M., Hünning P.S., Brambatti G., Albuquerque L., Neumann C. & Pigatto J.A. T. 2016 The aim was to investigate the ultrastructural changes in the corneal endothelium of pigs induced by intracameral 0.05% brilliant blue. Twenty swine corneas were separated into two groups, the right eye bulbs (control group) and the left eye bulbs (experimental group) of the same animal. All the eye bulbs were evaluated with specular microscopy. The cornea of the right eye bulbs was excised and in the left eye bulbs 0.2ml of 0.05% brilliant blue vital dye (OPTH-blue ® ) was injected into the anterior chamber, where it remained for one minute. Then the anterior chamber was cleaned with a balanced salt solution injection and the cornea was excised too. All the corneas were evaluated by scanning electron microscopy to evaluate the changes on the endothelium caused by the brilliant blue dye. There were no significant differences between the right corneal endothelium cells and the left corneal endothelium cells with scanning electron microscopy after intracameral use of 0.05% brilliant blue dye. The 0.05% brilliant blue dye concentration did not cause deleterious effects for the swine corneal endothelium after intracameral use and can be a choice for safe staining of the anterior capsule of the lens in cataract surgery.INDEX TERMS: Eye, brilliant blue 0.05%, toxicity, corneal endothelium, swine.
Procurou-se comparar duas técnicas de ovariosalpingohisterectomia (OSH): vídeo-assistida com dois portais e convencional em cadelas, ambas com o uso de equipamento Ligasure atlas®. Para tanto, foram utilizados 18 animais separados em dois grupos, sendo no primeiro grupo realizada a OSH por celiotomia e no segundo pelo acesso vídeo-assistido. Os procedimentos videocirúrgicos foram realizados por meio de dois trocartes dispostos nas regiões umbilical e pré-púbica, com os cães posicionados em decúbito dorsal. Em ambos os grupos, o único método de hemostasia empregado foi o Ligasure atlas®. Não houve diferença significativa acerca do tempo operatório, das complicações trans e pós-operatórias e das perdas sanguíneas. Conclui-se que a OSH vídeo-assistida com o uso de dois portais e Ligasure atlas® e a técnica convencional com o emprego do mesmo equipamento são rápidas, seguras e efetivas em cadelas.
RESUMOAvaliaram-se duas novas técnicas de inseminação laparoscópica intrauterina com o uso de agulha espinhal em ovinos. Foram realizadas quatro etapas experimentais, sendo os animais separados em dois grupos em cada etapa. Para tanto, foram utilizados os posicionamentos quadrupedal e dorsal. Realizou-se a inseminação de 80 ovinos após a sincronização de cio. Verificou-se que os acessos laparoscópicos propostos foram viáveis para a inseminação em ovinos. Considerou-se que a inseminação em posicionamento quadrupedal foi tecnicamente mais difícil se comparada ao acesso laparoscópico em decúbito dorsal, porém, com o aprimoramento da técnica e na dependência dos resultados quanto aos índices de prenhez, poderá se tornar procedimento adequado para a inseminação de ovelhas. Palavras-chave: ovelhas, videolaparoscopia, agulha espinhal, útero, prenhez ABSTRACT This study evaluated two new laparoscopic intrauterine insemination techniques with spinal needles in sheep.
Pesq. Vet. Bras. 33(7):920-923, julho 2013 920 RESUMO.-O presente trabalho objetivou avaliar uma técni-ca de vasectomia laparoscópica em macacos-prego (Cebus nigritus). Para tanto, foram utilizados oito animais submetidos à anestesia geral inalatória. Foram introduzidos três portais (dois de 5mm e um de 10mm) na parede abdominal ventral. Os ductos deferentes foram isolados, cauterizados com energia bipolar e seccionados próximo ao anel inguinal interno. Os procedimentos duraram 30,67+8,78 min. sem a ocorrência de complicações trans ou pós-operatórias o que permite concluir que a técnica proposta é adequada para essa espécie.
In the current experimental study, two different instruments were compared for prophylactic hemostasis during a 3-port technique of laparoscopic ovariohysterectomy (OVH) in bitches. Moreover, the need for port enlargement for specimen retrieval using 5mm or 10mm trocartes, technical difficulties and complications were assessed. Ultrasonic energy and a vascular sealing system were tested. Duration of surgery, patient weight and diameter of the uterine arteries and veins were compared among the groups. Fifteen dogs randomly divided into three groups (GI, GII, GIII) were submitted to ovariohysterectomy with hemostasis from the use of ultrasonic scalpel or vascular sealing equipment. In GI and GII the LigaSure ™ impedance-controlled bipolar vessel-sealing device was used, differing in the size of trocartes used between groups, and in GIII Autosonix ™ was used. Patients' weight, duration of surgery, technical difficulties and complications were compared among the groups. Statistical analysis showed no difference between the data analyzed among the groups. In conclusion, both methods of hemostasis were effective for 3-port total laparoscopic ovariohysterectomy in bitches. However, 5mm trocartes were not adequate for retrieval of the uterus and ovaries without need for enlargement of the port incision.Keywords: laparoscopy, canines, coagulation systems, spay, surgery RESUMO No presente experimento, foram comparados dois diferentes equipamentos, um com emprego de energia ultrassônica, e outro utilizando sistema de selamento vascular, como única forma de hemostasia em ovário-histerectomias laparoscópicas com três portais em cadelas. Ademais, a necessidade de ampliação da incisão do portal de 5mm ou de 10mm para a remoção dos espécimes ressecados, dificuldades técnicas e complicações foram avaliadas. Quinze cadelas aleatoriamente distribuídas em três grupos (GI, GII, GIII) foram submetidas à ovário-histerectomia com hemostasia a partir da utilização de bisturi
The goal of this study was to describe the normal values of corneal endothelial cell density and hexagonality in healthy rabbits’ eyes using contact specular microscopy. Both eyes of 18 rabbits, males and females, of different ages were evaluated. The eyes were divided into three groups of 12 each according to the age range of the animals: G1 (6 months old), G2 (12 months old), and G3 (48 months old). Parameters studied included mean endothelial cell density and hexagonality. For Group I, the mean cell density was 2307 cells per mm2. For GII, the mean cell density was 1895 cells per mm2. For G III, the mean cell density was 1818 cells per mm2. Cell density decreased significantly with aging (P<0.001) among the three groups. Pleomorphism in the rabbits of GI was 74.33±10.08. In the rabbits of GII it was 71.83±11.38. In the rabbits of GIII it was 64.02±28.80. Significant differences (P<0.001) were evident between GI and GIII and GII and GIII but not between Groups I and II. The results showed a decrease in number of cells and hexagonality with aging. Corneal endothelium of rabbits suffers changes due to advancing age both in terms of cell density and morphology.
A membrana pupilar persistente (MPP) é uma alteração congênita rara, caracterizada por finas faixas que atravessam a íris e geralmente não afetam a capacidade visual do indivíduo. Esta alteração não necessita obrigatoriamente de intervenção terapêutica; porém, o local de ligação dessa membrana pode gerar opacidade de córnea ou catarata. A etiologia não foi bem elucidada, entretanto, acredita-se que tenha fundo hereditário e esta alteração já foi relatada em humanos, cães, ratos e felinos. Foi atendimento, um felino, fêmea, não castrada, sem raça definida (SRD), aproximadamente 2 anos de idade, pesando 3,2 kg, encaminhado para avaliação pré-operatória de ovariohisterectomia eletiva, na qual observou-se a alteração ocular unilateral esquerda, compatível com membrana pupilar persistente. O objetivo deste trabalho foi apresentar um caso de MPP em um felino, espécie com rara incidência desta anomalia, tornando o caso relevante para melhor compreensão da epidemiologia desta condição. Por mais que a afecção não apresente uma repercussão ocular importante, recomenda-se de acompanhamento médico veterinário.
This study evaluated the cervical and transdiaphragmatic thoracoscopic approaches regarding their implementation, intrathoracic evaluation and application o f a chest tube, using the treatment o f pneumothorax as an experimental model. After injection o f 20ml kg'1 o f air per hemithorax, thoracoscopy was made by transdiaphragmatic paraxiphoid or cervical positions. After cavity examination, a thoracic drain was inserted using the surgical site to drain the pneumothorax. The cardiorespiratory function and arterial blood gas were measured during time o f evaluation. The cavity examination allowed visualizing the aspect and function o f intrathoracic structures. There were no significant differences between the two approaches when comparing the measurements made in each period evaluated. Both enabled intracavitary exploration and application o f thoracic drain. Cervical access shows viability, but resulted in the death o f two patients, and it not recommended as a substitute for the latter in the insertion o f thoracic drains in dogs. RESUMO Este estudo avaliou os acessos toracoscópicos cervical e paraxifóide em relação à sua aplicação, avaliação intratorácica e colocação de dreno torácico, utilizando o tratamento de pneumotórax como modelo experimental. Após a injeção de 20ml k g 1 de ar por hemitórax, a toracoscopia fo i realizada pelas técnicas cervical ou paraxifóide transdiafragmática. Após a exploração da cavidade, fo i inserido um dreno torácico utilizando o acesso cirúrgico para drenar o pneumotórax. A função cardiorrespiratória e a gasometria arterial foram aferidas durante o tempo de avaliação. A exploração da cavidade permitiu visualização do aspecto e função das estruturas intratorácicas. Não houve diferenças significativas entre os dois acessos quanto aos dados aferidos em cada período de avaliação. Ambos permitiram exploração intracavitária e aplicação do dreno torácico. O acesso cervical demonstra viabilidade, porém resultou na morte de dois pacientes, e não é recomendado como substituta à paraxifóide transdiafragmática para a aplicação de drenos torácicos em cães. Palavras-chave: canino, dreno torácico, pneumotórax, videocirurgia.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.