The science behind the buildup mechanism of polyelectrolyte multilayers is important for developing devices for various engineering applications. Here we, study the dependency of thickness of polyelectrolyte multilayer films, fabricated using spin-assisted layer-by-layer self-assembly of polyelectrolytes technique, with respect to varying spin-speed while keeping all other parameters of the fabrication process-window constant. The thickness measurements were performed using variable angle spectroscopic ellipsometry and atomic force microscopy. The experimentally observed results were validated mathematically using a Flory type theory. In addition, the biomolecular adsorption studies on these polyelectrolyte multilayer films fabricated at various spin-speeds, were also quantitatively analyzed using fluorescence microscopy studies. It was seen that the effect of spin-speed on the thickness of polyelectrolyte multilayers was negligible. In addition, it was also observed that the bio-molecular adsorption modalities onto these substrates were also independent of the spin-speed. This finding prompts to develop low-cost alternative technologies for various biomedical engineering applications, like functionalized substrates for centrifugal assay for fluorescence-based cell adhesion, wherein stability of films against strong mechanical forces generated during spinning can play an important role.
The matrix properties of polyelectrolyte multilayer thin films (PEM) are critical in making them a viable candidate for various biomedical applications. The location and ability of molecules to diffuse through the PEM architecture determines their encapsulation and release capabilities in a given matrix for various biomedical applications. The main aim of this review article is to provide a complete understanding of molecular transport on the surface as well as across the bulk of the PEM matrix. Different physiochemical strategies to promote or suppress the diffusivity of various molecules inside the PEM are mentioned in brief. A set of guiding principles is uncovered for getting a complete picture of loading and release of molecules across the PEM structure, which can play a key role in designing a desirable PEM assembly and have important implications for designing multicomponent, targeted and controlled drug‐delivery vehicles. Understanding the molecular diffusivity in PEM stack at the nano and micro scales will help to design superior host materials for biomedical engineering applications.
Etched Fiber Bragg Grating (EFBG) sensors are attractive from the point of the inherently high multiplexing ability of fiber based sensors. However, the strong dependence of the sensitivity of EFBG sensors on the fiber diameter requires robust methods for calibration when used for distributed sensing in a large array format. Using experimental data and numerical modelling, we show that knowledge of the wavelength shift during the etch process is necessary for high-fidelity calibration of EFBG arrays. However as this approach requires the monitoring of every element of the sensor array during etching, we also proposed and demonstrated a calibration scheme using data from bulk refractometry measurements conducted post-fabrication without needing any information about the etching process. Although this approach is not as precise as the first one, it may be more practical as there is no requirement to monitor each element of the sensor array. We were able to calibrate the response of the sensors to within 3% with the approach using information acquired during etching and to within 5% using the post-fabrication bulk refractometry approach in spite of the sensitivities of the array element differing by more than a factor of 4. These two approaches present a tradeoff between accuracy and practicality.Index Terms-Etched fiber Bragg grating, FBG sensor arrays, fiber array based biosensing.
Layer-by-layer (LbL) self-assembled polyelectrolyte multilayer (PEM) films are a simple yet elegant bottom-up technology to create films at the nano−microscale. This low-cost technology has been widely used as a universal functionalization technique on a broad spectrum of substrates. Biomolecules under investigation can be incubated onto films based on complementary charge interactions between the films and biomolecules. There is a great demand for developing an ultralow-cost biosensing device, which can optimally enhance the fluorescence signal of the adsorbed biomolecules from the traditional labeled sensing platforms. In this work, we have incorporated a blend of the conventional metal enhanced fluorescence technology and the PEM as a dielectric spacer and functionalized film, coated on an aluminum paper (tape)-based substrate. These device has been found to be capable of holding biomolecules in three-dimensional PEM space. The devices fabricated by the proposed spray LbL technique provide significant fluorescence signal enhancement by holding a relatively higher mass per volume of the adsorbed biomolecules, when compared to traditional spin-and dip-coating techniques. Interestingly, our proposed device has expressed a fluorescence enhancement factor, which is 9 times higher than PEM-functionalized glass-based devices. To demonstrate the practical utility of our devices, we also compared our devices to Whatman FAST slides. Our experimental fluorescence results are almost comparable to Whatman FAST slides. Such PEM devices fabricated on top of low-cost aluminum tape using a spray LbL technique give new insights into the future development of ultralow-cost, high-throughput, and disposable lab-on-chip diagnostic applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.