Background This prospective comparative study was done to evaluate the effectiveness of implants of different design (titanium elastic intramedullary nail versus anatomical precontoured dynamic compression plate) in treatment of displaced midshaft clavicular fractures.Materials and methods Sixty-six patients between 18 and 65 years of age were included in this study. They were randomized in two groups to be treated with either elastic intramedullary nail (EIN) or plate. Clinical and radiological assessments were performed at regular intervals. Outcomes and complications of both groups over 2 years of follow-up time were compared.ResultsLength of incision, operation time, blood loss and duration of hospital stay were significantly less for the EIN group. American Shoulder and Elbow Surgeons (ASES) and Constant Shoulder scores were significantly higher (p < 0.05) in the plating group than the EIN group for the first 2 months but there was no significant difference found between the two groups regarding functional and radiological outcome at the 2-year follow-up. Significantly higher rates of refracture after implant removal (p = 0.045) in the plating group was observed. Infection and revision surgery rates were also higher in the plate group, but this difference was insignificant (p > 0.05).ConclusionsEIN is a safe, minimally invasive surgical technique with a lower complication rate, faster return to daily activities, excellent cosmetic and comparable functional results, and can be used as an equally effective alternative to plate fixation in displaced midshaft clavicle fractures.Level of evidenceLevel 2.
IntroductionOsteoarthritis (OA) is a progressively debilitating disease that affects mostly cartilage, with associated changes in the bone. The increasing incidence of OA and an ageing population, coupled with insufficient therapeutic choices, has led to focus on the potential of stem cells as a novel strategy for cartilage repair.MethodsIn this study, we used scaffold-free mesenchymal stem cells (MSCs) obtained from bone marrow in an experimental animal model of OA by direct intra-articular injection. MSCs were isolated from 2.8 kg white New Zealand rabbits. There were ten in the study group and ten in the control group. OA was induced by unilateral transection of the anterior cruciate ligament of the knee joint. At 12 weeks post-operatively, a single dose of 1 million cells suspended in 1 ml of medium was delivered to the injured knee by direct intra-articular injection. The control group received 1 ml of medium without cells. The knees were examined at 16 and 20 weeks following surgery. Repair was investigated radiologically, grossly and histologically using haematoxylin and eosin, Safranin-O and toluidine blue staining.ResultsRadiological assessment confirmed development of OA changes after 12 weeks. Rabbits receiving MSCs showed a lower degree of cartilage degeneration, osteophyte formation, and subchondral sclerosis than the control group at 20 weeks post-operatively. The quality of cartilage was significantly better in the cell-treated group compared with the control group after 20 weeks.ConclusionsBone marrow-derived MSCs could be promising cell sources for the treatment of OA. Neither stem cell culture nor scaffolds are absolutely necessary for a favourable outcome.Cite this article: Bone Joint Res 2014;3:32–7.
Our study has shown that decreasing the tibial slope >5° compared to pre-operative value has functionally favourable effect on the reconstructed ACL graft and outcome. It is known that increasing slope causes an anterior shift in tibial resting position that is accentuated under axial loads. This suggests that decreasing tibial slope may be protective in an ACL deficient knee. Hence by placing the tricortical graft posterior to midline in the opening wedge reduces the posterior tibial slope and thereby reduces the stress on the graft leading to better functional outcome.
This study concludes that both the implants can be used in non-union of humeral shaft fractures with good functional outcomes and acceptable rate of complications.
Background:Rotator cuff tears are a common cause of shoulder pain and dysfunction. More recently, there has been a renewed interest in understanding the subscapularis tears. There are multiple articles in the literature showing the short term results of isolated subscapularis tendon repair. However, the midterm and long term outcome studies for arthroscopic subscapularis repair are few. This study evaluates the functional outcome after arthroscopic subscapularis repair.Materials and Methods:The records of 35 patients who underwent an arthroscopic subscapularis repair between May 2008 and June 2012 were included in this retrospective study. The records of all patients were reviewed. There were 22 males and 13 female patients with mean age of 58.2 years (range 41-72 years). All patients had a complete history, physical examination, and radiographs of their shoulders. Visual analogue scale (VAS), range of movements, power of cuff muscles, and modified University of California at Los Angeles (UCLA) score were assessed.Results:The mean followup was 2.8 years (range 2-4 year). Functional outcome after arthroscopic subscapularis repair has an excellent outcome as analysed by clinical outcome, VAS score and UCLA score. Results were analyzed and had statistically significant values. The VAS for pain improved significantly (P < 0.001), and the mean modified UCLA score improved significantly (P < 0.001) from 14.24 ± 4.72 preoperatively to 33.15 ± 2.29 at 2 years postoperative. According to the UCLA system, there were 22 excellent, 11 good, and 2 fair results. Around 95% of patients returned to their usual work after surgery.Conclusion:At a median followup of 2 years, 95% of patients had a good to excellent result after an arthroscopic subscapularis tendon repair. We conclude that the midterm results show that arthroscopic subscapularis repair remains a good option for the treatment of patients with subscapularis tendon repair.
Introduction: Pigmented VillonodularSynovitis is a rare, benign condition which is locally aggressive and can undergo malignant transformation. It is characterized mostly with a hyper plastic synovium, large effusion and bone erosions. On an average it is clinically correctly identified after 4.4 years of presentation. It mostly involves the smaller joints and in larger joints commonly seen in the knee joint. Case Report: 49 years old male presented with right knee pain since 3 months, insidious in onset, localized in nature, with difficulty in walking and sitting for a long time with no episode of injury on the right knee. The patient had one episode of instability with occasional episodes of locking. Clinically there was retro patellar tenderness with full range of movement of the knee. MRI showed a lesion measuring approximately1.5*1.5*0.5 cm in the retropatellar space suspected to be a loose body. Arthroscopically a localized soft tissue growth was noted in the retropatellar space which was resected. Histology of the resected lesion demonstrated localized PVNS. Conclusion: The findings in this case suggest that localized PVNS may be mistaken as a loose body radiologically and there must be a high suspicion of PVNS in a localized abnormal growth in the knee joint.
Abstract:Articular cartilage flap tear of patella is a rare injury that occurs in children. Diagnosis is difficult both clinically and radiologically. Apart from knee swelling and retro-patellar tenderness, there is no other clinical finding. We report a case of 16 year old boy who suffered from patella cartilage flap tear without visible bony fragments. Mini-open reduction, microdrilling, sealing of margins with fibrin glue and double breasting of medial patellar retinaculum was performed. Early weight bearing was achieved together with a satisfactory range of knee motion. An awareness of cartilage flap tear, together with its characteristic clinical and radiological features and proper treatment is necessary to avoid misdiagnosis and treatment delay.
Background:The purpose of this study was to compare the resistance of intramedullary single screw device (Gamma nail) and double screw device proximal femoral nail (PFN) in unstable trochanteric fractures in terms of the number of cycles sustained, subsidence and implant failure in an axial loading test in cadaveric femora.Materials and Methods:The study was conducted on 18 dry cadaveric femoral specimens, 9 of these were implanted with a Gamma nail and 9 with PFN. There was no significant difference found in average dual energy X-ray absorptiometry value between both groups. The construct was made unstable (AO type 31A3.3) by removing a standard sized posteromedial wedge. These were tested on a cyclic physiological loading machine at 1 cycle/s with a load of 200 kg. The test was observed for 50,000 loading cycles or until implant failure, whichever occurred earlier. Peak displacements were measured and analysis was done to determine construct stiffness and gap micromotion in axial loading.Result:It was observed that there was statistically significant difference in terms of displacement at the fracture gap and overall construct stiffness of specimens of both groups. PFN construct group showed a mean subsidence of 1.02 mm and Gamma nail construct group showed mean subsidence of 2.36 mm after cycling. The average stiffness of Gamma nail group was 62.8 ± 8.4 N/mm which was significantly lower than average stiffness of the PFN group (80.4 ± 5.9 N/mm) (P = 0.03). In fatigue testing, 1 out of 9 PFN bone construct failed, while 5 of 9 Gamma nail bone construct failed.Conclusion:When considering micromotion (subsidence) and incidence of implant/screw failure, double screw device (PFN) had statistically significant lower micromotion across the fracture gap with axial compression and lower incidence of implant failure. Hence, double screw device (PFN) construct had higher stability compared to single screw device (GN) in an unstable trochanteric fracture femur model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.