Background: Age is considered as an important factor for the development of sublingual varices (SV). It has been suggested that some other conditions such as gender, systemic diseases, smoking, denture wearing may play a role in aetiology. However, there are a limited number of studies investigating these associations. This study was perform to evaluate association between SV and the conditions which are described as possible risk factors previously. Materials and methods: A total of 691 patients (470 females, 221 males) who attended for comprehensive clinical examination were included in the study. Age, gender, systemic health, venous varix of the lower extremities, smoking status, denture wearing were recorded during the history taking. SV were classified into two categories: stage 0 (few or none visible) and stage 1 (moderate or severe). Tongue photographs were taken from a group of these patients. For the evaluation of intra-observer reliability, 60 photographs of tongue were re-evaluated by the same observer. Intra-observer reliability was evaluated using Kappa statistics. Pearson c 2 test and Fisher's exact test were used to assess SV in relation to each variable, and variables showing associations with p < 0.05 were selected for the multivariable analysis, then logistic regression analysis was applied. Results: Kappa value of intra-observer reliability was 0.91. SV were significantly associated with age (odds ratio [OR] = 1.08, p = 0.000), hypertension (OR = 2.3, p = 0.007) and denture wearing (OR = 2.17, p = 0.02). Conclusions: The presence of SV is associated with hypertension and denture wearing as well as aging. More detailed studies are needed to prove causative relations between SV and systemic diseases.
The objective of this clinical study was to compare conventional caries detection techniques, pen-type laser fluorescence device, and near-infrared light transillumination method in approximal dentin caries lesions. The study included 157 patients, aged 12-18, without any cavity in the posterior teeth. Two calibrated examiners carried out the assessments of selected approximal caries sites independently. After the assessments, the unopened sites were excluded and a total of 161 approximal sites were included in the study. When both the examiners arrived at a consensus regarding the presence of dentin caries, the detected lesions were opened with a conical diamond burr, the cavity extent was examined and validated (gold standard). Sensitivity, specificity, negative predictive value, positive predictive value, accuracy, and area under the ROC curve (Az) values among the caries detection methods were calculated. Bitewing radiography and near-infrared (NIR) light transillumination methods showed the highest sensitivity (0.83-0.82) and accuracy (0.82-0.80) among the methods. Visual inspection showed the lowest sensitivity (0.54). Laser fluorescence device and visual inspection showed nearly equal performance. Near-infrared light transillumination can be used as an alternative method to approximal dentin caries detection. Visual inspection and laser fluorescence device alone should not be used for approximal dentin caries.
Conventional methods of caries detection, including the gold standard of histological examination, have certain disadvantages that must be addressed prior to validating any other diagnostic technique-current or new. Here we evaluated the validity of micro-computed tomography (micro-CT) as an alternative gold-standard technique for caries detection. Sixty teeth with suspected occlusal caries were chosen from a pool of teeth extracted for orthodontic, periodontal, or surgical reasons. Identical reference points were marked on photographs taken for teeth and were used to evaluate each method. Dimensions of caries were assessed by two calibrated examiners using the ICDAS-II visual examination system, bitewing radiographs, and micro-CT. The teeth included in the study were selected randomly from solution before all measurements. For micro-CT, the device was set to 50 kV, 800 µA, pixel size 15 µm (at 1024 × 1024 resolution), and 1° rotation step. NRecon software (SkyScan) was used to obtain reconstructed images. For each diagnostic method, results were compared with histology results using the McNemar test. Receiver operator characteristic (ROC) analysis was also performed for each method (Z-test; p < 0.05). Besides showing a high correlation with histology results, micro-CT yielded the greatest values at the D3 threshold; moreover, accuracy and area under the ROC curve (AUC) values were greatest at the D1threshold. Our results indicate that micro-CT performs as well as or better than histological examination for the purpose of comparing methods for caries detection.
Lung cancer is a complex, multifactorial disease which is the leading cause of cancer death in both men and women. NF-κB is a transcription factor which is known to affect the expression of more than 150 genes related to inflammation, lymphocyte activation, cell proliferation, differentiation, and apoptosis, as well as contributing to cell apoptosis and survival. However, NF-κBIA (IκBα) is the inhibitor of the transcription factor. The -94ins/delATTG polymorphism of the NF-κB1 gene promoter region which causes a functional effect and NF-κBIA 3′UTR A → G polymorphism has been shown to be related to various inflammatory diseases and cancer. Ninety-five NSCLC patients and 99 healthy controls were included in study. The NF-κB1 -94ins/delATTG and NF-κBIA 3′UTR A → G polymorphism have been studied by using PCR-RFLP method. It was found that the NF-κB1 -94ins/delATTG DD genotype and D allele frequencies were higher in patients than healthy controls and the presence of the DD genotype has a 3.5-fold increased risk of the disease (P: 0.014). This study is the first to investigate the NF-κB1 -94ins/delATTG and NF-κBIA 3′UTR A → G polymorphism together in the Turkish population. According to the results, the NF-κB1 -94ins/del ATTG promoter polymorphism may have a role in lung carcinogenesis and prognosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.