Background
Due to its bone preserving philosophy, short-stem total hip arthroplasty (THA) has primarily been recommended for young and active patients. However, there may be benefits for elderly patients given a less invasive operative technique due to the short curved implant design. The purpose of this study was to compare the clinical and radiological outcomes as well as perioperative complications of a calcar-guided short stem between a young (< 60 years) and a geriatric (> 75 years) population.
Methods
Data were collected in a total of 5 centers, and 400 short-stems were included as part of a prospective multicentre observational study between 2010 and 2014 with a mean follow-up of 49.2 months. Preoperative femur morphology was analysed using the Dorr classification. Clinical and radiological outcomes were assessed in both groups as well as perioperative complications, rates and reasons for stem revision.
Results
No differences were found for the mean visual analogue scale (VAS) values of rest pain, load pain, and satisfaction, whereas Harris Hip Score (HHS) was slightly better in the young group. Comparing both groups, none of the radiological parameters that were assessed (stress-shielding, cortical hypertrophy, radiolucency, osteolysis) reached differences of statistical significance. While in young patients aseptic loosening is the main cause of implant failure, in the elderly group particularly postoperative periprosthetic fractures due to accidental fall have to be considered to be of high risk. The incidence of periprosthetic fractures was found to be 0% in Dorr type A femurs, whereas in Dorr types B and C fractures occurred in 2.1 and 22.2% respectively.
Conclusions
Advanced age alone is not necessarily to be considered as contra-indications for calcar-guided short-stem THA, although further follow-up is needed. However, markedly reduced bone quality with femur morphology of Dorr type C seems to be associated with increased risk for postoperative periprosthetic fractures, thus indication should be limited to Dorr types A and B.
Trial registration
German Clinical Trials Register;
DRKS00012634
, 07.07.2017 (retrospectively registered).
Complications related to the neck-stem junction of modular stems used for total hip arthroplasty (THA) are generating increasing concern. A 74-year-old male had increasing pain and a cutaneous reaction around the scar 1 year after THA with a modular neck-stem. Imaging revealed osteolysis of the calcar and a pseudo-tumour adjacent to the neck-stem junction. Serum cobalt levels were elevated. Revision surgery to exchange the stem and liner and to resect the pseudo-tumour was performed. Analysis of the stem by scanning electron microscopy and by energy dispersive X-ray and white light interferometry showed fretting corrosion at the neck-stem junction contrasting with minimal changes at the head-neck junction. Thus, despite dry assembly of the neck and stem on the back table at primary THA, full neck-stem contact was not achieved, and the resulting micromotion at the interface led to fretting corrosion. This case highlights the mechanism of fretting corrosion at the neck-stem interface responsible for adverse local tissue reactions. Clinical and radiological follow-up is mandatory in patients with dual-modular stems.
Femoral neck stress fractures (FNSFs) can be treated conservatively or surgically, depending on initial displacement and patient condition. Surgical treatment options include internal fixation, with or without valgus osteotomy or hip arthroplasty, either hemi or total. The latter is mainly considered when initial treatment fails. A review of the literature shows that total hip arthroplasty (THA) is only considered as primary treatment in displaced fractures (type 3) in low-demand patients. We present a case of successive bilateral FNSF in a young active patient, where a THA was performed on one side, after failed internal fixation, and where it was chosen as primary treatment on the other side after failed conservative treatment.
Introduction Quadriceps tendon ruptures (QTR) frequently occur in patients with end-stage renal failure, while triceps brachii tendon ruptures (TTR) are less common. This is the first properly documented report of a simultaneous ipsilateral traumatic rupture of both of these tendons. Case Report A 50-year-old patient, on hemodialysis for end-stage renal failure, fell on his right side. He presented with sudden right knee and elbow pain, with functional impairment of both joints. X-rays showed avulsion-like osseous lesions on the olecranon and patella with a low-riding patella. Ultrasound confirmed complete quadriceps and triceps avulsion ruptures. Both lesions were treated surgically. Fixation was performed with anchors using the Krackow suture technique for both tendons. Postoperative clinical and radiological results were satisfactory, and follow-up was uneventful. The patient regained his preinjury functional level with a complete range of motion of both his knee and elbow. Discussion Isolated QTR and TTR are frequent lesions in chronic renal failure patients treated with hemodialysis. Simultaneous ipsilateral rupture of both tendons however is extremely rare and should therefore not be overlooked. Surgical treatment is recommended for complete ruptures.
Primary tumors of the pelvis are considered difficult to treat due to the complex anatomy and the proximity of important neurovascular structures. The surgical armamentarium for the treatment of these tumors has evolved with the help of cutting-edge technology from debilitating hemipelvectomies to solutions such as precise resections guided by patient-specific instruments or computer navigation and reconstruction by modular prostheses, 3D-printed custom-made implants, or orthotopic autograft reimplantation after extracorporeal irradiation. Different combinations of these techniques have been described in the literature with various rates of success. We present two cases of pelvic chondrosarcomas successfully treated by a combination of periacetabular resection with patient-specific osteotomy guides and orthotopic reimplantation of the extracorporeally irradiated autograft resulting in retention of the native hip.
Background
Total knee arthroplasty (TKA) is most frequently planned using conventional two-dimensional weight-bearing lower limb radiographs and is performed with conventional femoral and tibial cutting guides. Questions have been raised about the accuracy of conventional TKA instrumentation and planning for an anatomically standard or complex joint. Use of computed tomography (CT)-based three-dimensional (3D) templating and patient-specific cutting guides printed in 3D has shown improved postoperative lower limb alignment parameters. This case-control study compared costs and operative times of using CT-based, patient-specific, single-use instruments versus conventional metal instruments for TKA.
Methods
In this case-control, retrospective chart review, all TKAs were performed by one senior surgeon, using the F.I.R.S.T. posterior-stabilised knee prosthesis (Symbios, CH), with a similar protocol and identical operating room setup. Group A included 51 TKAs performed with patient-specific cutting guides and conventional metal instruments. Group B included 49 TKAs performed with patient-specific cutting guides and patient-specific, single-use instrumentation. Operation duration, number of instrumentation trays and sterilisation costs were evaluated.
Results
The groups were similar for age, body mass index, hip-knee-ankle angle and operation duration. The mean number of instrumentation trays was 8.0 ± 0.8 for group A (controls) and 5.1 ± 0.9 for group B (p<0.001). The mean sterilisation costs were 380 ± 47 Swiss Francs (CHF) for group A and 243 ± 55 CHF for group B (p<0.001), for a mean cost reduction of 130.50 CHF per intervention in group B. The time interval between two consecutive surgeries was 24 min for group A and 18 min for group B. There were no adverse events or complications, instrument-related or otherwise.
Conclusion
Compared to conventional instrumentation, use of patient-specific, single-use instruments for TKA reduced the number of instrumentation trays by more than one-third and saved 36% in sterilisation costs. If fabrication costs of single-use instruments are included by the company, the total cost is significantly diminished. There was no operative time advantage for single-use instrumentation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.