The literature in this area is scarce and the evidence is weak. Most studies were retrospective, and confounding factors were poorly defined or not addressed. There is thus currently insufficient evidence to conclude that an intra-articular corticosteroid injection administered prior to THA increases the rate of infection. High quality, multicentre randomised trials are needed to address this issue. Cite this article: Bone Joint J 2016;98-B:1027-35.
This paper describes the application of solid finite element models in the analysis of five tubular specimens containing interacting corrosion defects. Each of these specimens has been submitted to hydrotest up to failure as part of a previous research project. The specimens were cut from longitudinal welded tubes made of API 5L X80 steel with a nominal outside diameter of 457.2 mm (18 in) and a nominal wall thickness of 7.93 mm (0.312 in). The analyses accounted for large strains and displacements, stress-stiffening and material nonlinearity. The failure pressures predicted by the solid finite element models are compared with the failure pressures of these specimens measured in the laboratory burst tests carried out previously. Also the failure behavior of each specimen is described and illustrated by contour plots of stresses.
The standard goniometer (SG) is the most commonly used tool to assess range of motion (ROM) in patients with knee restrictions. Several medical applications have been designed to measure joint ROM. Little data are available on their reliability in the postoperative clinical setting. The purpose of this study was to assess whether a smartphone accelerometer-based knee goniometer application (App) is as reliable as the SG to measure knee ROM in clinical settings. A total of 60 subjects were included in this cross-sectional reliability trial. Overall, 20 healthy subjects (HS) and 20 acute postoperative patients (PO) underwent three active and three passive measurements in knee flexion and extension, using the SG and the smartphone knee goniometer App. To determine the fatigability of postoperative patients, a third group of 20 patients underwent a single active measurement in knee flexion and extension (PO1). Measurements were performed by three clinicians. For intraobserver reliability, mean intraclass correlation coefficient (ICC) values were higher for the App in all circumstances (overall mean SG 0.85, App 0.91), indicating an excellent correlation. For interobserver reliability, the highest ICC scores were in the PO1 group, with the App more consistent than the SG in all movements. Interobserver reliability was lower in the PO group versus PO1. Interobserver reliability was better for active ROM than for passive measurements. The overall concordance coefficient was very good to excellent with active measurements (range, 0.60-0.97). In conclusion, the App is a reliable tool for use in acute orthopedic care and offers better intra- and interobserver correlation scores for a single active measurement.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.