Nursing workload is--against a common belief--decreased by systematic implementation of enhance recovery protocol. The higher the compliance with the pathway, the lower the burden for the nurses!
Among instruments measuring spiritual well-being, the Functional Assessment of Chronic Illness Therapy-Spiritual well-being (FACIT-Sp-12) is the most widely used instrument in research. It has been validated in patients suffering from cancer or HIV/AIDS, but has rarely been used in elderly patients. The objectives of this study were to determine the psychometric properties and suitability of the FACIT-Spto assess spiritual well-being in hospitalized elderly patients. This cross-sectional study uses a mixed method approach. Subjects were patients (N = 208), aged 65 years and older, consecutively admitted in post-acute rehabilitation. Psychometric properties of the FACIT-Sp were investigated. The internal structure of the FACIT-Sp (factor structure and internal consistency) was assessed. Convergent validity of the FACIT-Sp was assessed using the Spiritual Distress Assessment Tool (SDAT), the question "Are you at peace?" and the Geriatric Depression Scale (GDS). Predictive validity was assessed using length of stay (LOS) and discharge destination. Understanding and interpretation of FACIT-Sp items were consecutively assessed in a sub-sample of 135 patients. Results show that FACIT-Sp scores ranged from 7 to 46 (mean 29.6 ± 7.8); 23.1% of the patients had high spiritual well-being. Cronbach's α was good (0.85). Item-to-total correlations were all significant (0.34 to 0.73). Principal component analyses performed with 2 or 3 factors were only moderately consistent with previous work. FACIT-Sp correlated with SDAT, "Are you at peace?" and GDS (Rho = −0.45, P < 0.001; 0.51, P < 0.001 and −0.38, P < 0.001). No association was found with LOS or discharge destination. Spontaneous comments about one or more FACIT-Sp items were made by 97/135 (71.9%). Specifically, items that address purpose and meaning in life were frequently found difficult to answer. Analyses suggest that the FACIT-Sp may underestimate spiritual well-being in older patients. In conclusion, despite having acceptable psychometric properties, * Corresponding author. S. Monod et al. 1312 the FACIT-Sp presents limitations for measurement of spiritual well-being in hospitalized elderly patients.
BackgroundThe evaluation of swelling is important for the outcome of total knee arthroplasty (TKA) surgery. The circumference or volume measurements are applicable at the bedside of the patient but are altered by muscular atrophy and the post-surgical dressing. Bioimpedance spectroscopy might overcome these limitations; however, it should be validated. This study aimed to explore the validity, the reliability and the responsiveness of bioimpedance spectroscopy for measuring swelling after TKA.MethodsThe degree of swelling in 25 patients undergoing TKA surgery was measured using bioimpedance spectroscopy (BIS R0), knee circumference and limb volume. The measurements were performed on D-1 (day before surgery), D + 2 (2 days after surgery) and D + 8 (8 days after surgery). The BIS R0 measurements were repeated twice, alternating between two evaluators. The percentage of the difference between the limbs was calculated for BIS R0, circumference and volume. The intra- and inter-observer intraclass correlation coefficients (ICCs), limits of agreement (LOA), effect size (Cohen’s d), correlations between the methods and diagnostic sensitivity were calculated.ResultsBIS R0, circumference and volume detected swelling < 3.5% at D-1. The swelling at D2 and D8 was greater with BIS R0 [mean (SD) 29.9% (±9.8) and 38.27 (±7.8)] than with volume [14.7 (±9.5) and 14.9 (±8.2)] and circumference [11.1 (±5.7) and 11.7 (±4.1)].The BIS R0 intra- and inter-evaluator ICCs ranged from 0.89 to 0.99, whereas the LOA were < 5.2%. The BIS R0 correlation was 0.73 with volume and 0.75 with circumference. The BIS R0 Cohen’s d was 3.32 for the D-1–D2 evolution. The diagnostic sensitivity was 83% D2 and 96% at D8.ConclusionBioimpedance is a valid method for the evaluation of swelling following TKA. BIS R0 also demonstrated excellent intra- and inter- evaluator reliability. The diagnostic sensitivity and responsiveness is superior to that of concurrent methods. BIS R0 is an efficient method for post-surgical follow up at the bedside of the patient. The measurement of BIS R0 is a straightforward, valid, reliable and responsive method for lower limb swelling following TKA surgery that could be used in clinics and research.Trial registrationClinicalTrials.gov Identifier: NCT00627770.
Objective To assess the impact of implementation of the TeamSTEPPS teamwork improvement concept on patient safety culture. Design Pre-post culture assessment using the Hospital Survey on Patient Safety Culture, at baseline and one year after implementation of TeamSTEPPS. Setting Two maternity wards within the same 480-bed multisite teaching hospital. Intervention Implementation of the TeamSTEPPS teamwork improvement concept. Main Outcome Measures Analysis of variation of the percentage of positive responses (score) in both wards (intervention and control) was conducted. Results There was a significant increase in scores in three dimensions of patient safety culture in the intervention ward: Supervisor/Manager Expectations and Actions Promoting Safety increased from 48.7% in 2015 to 70.8% in 2016 (P < 0.005); Teamwork Within Units increased from 35.5% in 2015 to 54.5% in 2016 (P < 0.005); Nonpunitive Response to Errors increased from 16.7% in 2015 to 32.3% in 2016 (P < 0.005). Other dimensions showed no significant changes. In the control ward, there was a significant decrease in scores in one dimension. A secondary analysis of differences in differences still shows significant improvement in one dimension (Supervisor/Manager Expectations and Actions Promoting Safety P < 0.005). Conclusion After implementing the TeamSTEPPS teamwork concept, patient safety culture significantly improved for three of twelve dimensions in the intervention group. When controlling for differences in baseline scores between implementation and control wards, a significant improvement remains in one dimension. This suggests that TeamSTEPPS could be considered when seeking to enhance patient safety culture, especially in high-risk environments such as maternity wards.
The standard goniometer (SG) is the most commonly used tool to assess range of motion (ROM) in patients with knee restrictions. Several medical applications have been designed to measure joint ROM. Little data are available on their reliability in the postoperative clinical setting. The purpose of this study was to assess whether a smartphone accelerometer-based knee goniometer application (App) is as reliable as the SG to measure knee ROM in clinical settings. A total of 60 subjects were included in this cross-sectional reliability trial. Overall, 20 healthy subjects (HS) and 20 acute postoperative patients (PO) underwent three active and three passive measurements in knee flexion and extension, using the SG and the smartphone knee goniometer App. To determine the fatigability of postoperative patients, a third group of 20 patients underwent a single active measurement in knee flexion and extension (PO1). Measurements were performed by three clinicians. For intraobserver reliability, mean intraclass correlation coefficient (ICC) values were higher for the App in all circumstances (overall mean SG 0.85, App 0.91), indicating an excellent correlation. For interobserver reliability, the highest ICC scores were in the PO1 group, with the App more consistent than the SG in all movements. Interobserver reliability was lower in the PO group versus PO1. Interobserver reliability was better for active ROM than for passive measurements. The overall concordance coefficient was very good to excellent with active measurements (range, 0.60-0.97). In conclusion, the App is a reliable tool for use in acute orthopedic care and offers better intra- and interobserver correlation scores for a single active measurement.
Kinematic functional evaluation with body-worn sensors provides discriminative and responsive scores after shoulder surgery, but the optimal movements' combination has not yet been scientifically investigated. The aim of this study was the development of a simplified shoulder function kinematic score including only essential movements. The P Score, a seven-movement kinematic score developed on 31 healthy participants and 35 patients before surgery and at 3, 6 and 12 months after shoulder surgery, served as a reference. Principal component analysis and multiple regression were used to create simplified scoring models. The candidate models were compared to the reference score. ROC curve for shoulder pathology detection and correlations with clinical questionnaires were calculated. The B-B Score (hand to the Back and hand upwards as to change a Bulb) showed no difference to the P Score in time*score interaction (P > .05) and its relation with the reference score was highly linear (R(2) > .97). Absolute value of correlations with clinical questionnaires ranged from 0.51 to 0.77. Sensitivity was 97% and specificity 94%. The B-B and reference scores are equivalent for the measurement of group responses. The validated simplified scoring model presents practical advantages that facilitate the objective evaluation of shoulder function in clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.