IntroductionSimulated-use buildup biofilm (BBF) model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes.Materials and methodsBBF was formed in polytetrafluorethylene channels using Enterococcus faecalis, Escherichia coli, and Pseudomonas aeruginosa. Sterile reverse osmosis (RO) water, and phosphate-buffered saline with and without Tween80 as well as two neutralizing broths (Letheen and Dey–Engley) were each assessed with and without friction. Neutralizer was added immediately after sample collection and samples concentrated using centrifugation. Simulated-use testing was done using TJF-Q180V and JF-140F Olympus duodenoscopes.ResultsDespite variability in the bacterial CFU in the BBF model, none of the extraction fluids tested were significantly better than RO. Borescope examination showed far less residual material when friction was part of the extraction protocol. The RO for flush-brush-flush (FBF) extraction provided significantly better recovery of E. coli (p = 0.02) from duodenoscope lever cavities compared to the CDC flush method.Discussion and conclusionWe recommend RO with friction for FBF extraction of the channel and lever cavity of duodenoscopes. Neutralizer and sample concentration optimize recovery of viable bacteria on culture.
OBJECTIVE Biofilm has been implicated in bacterial persistence and survival after endoscope reprocessing. In this study, we assessed the impact of different methods of reprocessing on organic residues and viable bacteria after repeated rounds of biofilm formation when each was followed by full reprocessing. METHODS ATS-2015, an artificial test soil containing 5-8 Log10 colony-forming units (CFU) of Enterococcus faecalis and Pseudomonas aeruginosa, was used to form biofilm in polytetrafluroethylene channels overnight on 5 successive days. Each successive day, full pump-assisted cleaning using bristle brushes or pull-through devices in combination with enzymatic or nonenzymatic detergents followed by fully automated endoscope reprocessor disinfection using peracetic acid was performed. Residuals were visualized by scanning electron microscopy (SEM). Destructive testing was used to assess expected cutoffs for adenosine triphosphate (ATP; <200 relative light units), protein (<2 µg/cm2), and viable bacteria count (0 CFU). RESULTS Protein residuals were above 2 µg/cm2, but ATP residuals were <200 relative light units for all methods tested. Only when enzymatic cleaner was used for cleaning were there no viable bacteria detected after disinfection irrespective of whether bristle brushes or pull-through devices were used. SEM revealed that some residual debris remained after all reprocessing methods, but more residuals were detected when a nonenzymatic detergent was used. CONCLUSIONS Surviving E. faecalis and P. aeruginosa were only detected when the non-enzymatic detergent was used, emphasizing the importance of the detergent used for endoscope channel reprocessing. Preventing biofilm formation is critical because not all current reprocessing methods can reliably eliminate viable bacteria within the biofilm matrix. Infect Control Hosp Epidemiol 2017;38:1284-1290.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.