2017
DOI: 10.1016/j.gie.2017.03.081
|View full text |Cite
|
Sign up to set email alerts
|

270 Prevention of Biofilm Accumulation in Duodenoscopes Varies With the Method of Reprocessing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
3
0
4

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 0 publications
0
3
0
4
Order By: Relevance
“…En los establecimientos donde se adoptó el método automatizado, la mayoría de los profesionales desconocía que el mecanismo del elevador debe permanecer en posición vertical durante todo el proceso, para permitir un mayor contacto con las soluciones de limpieza y desinfección (3,14) . Ese hallazgo es importante, debido a que la inadecuada posición de este dispositivo favorece la acumulación de suciedad y microorganismos, especialmente en su cara posterior y, por ende, que permanezcan los microorganismos en la estructura (22) .…”
Section: Resultsunclassified
See 1 more Smart Citation
“…En los establecimientos donde se adoptó el método automatizado, la mayoría de los profesionales desconocía que el mecanismo del elevador debe permanecer en posición vertical durante todo el proceso, para permitir un mayor contacto con las soluciones de limpieza y desinfección (3,14) . Ese hallazgo es importante, debido a que la inadecuada posición de este dispositivo favorece la acumulación de suciedad y microorganismos, especialmente en su cara posterior y, por ende, que permanezcan los microorganismos en la estructura (22) .…”
Section: Resultsunclassified
“…Las fallas durante el procesamiento de dicho equipo han sido causas importantes de varios brotes infecciosos, que afectaron a innumerables pacientes en diferentes países del mundo (16,(24)(25) . Este desconocimiento indica que es necesario capacitar con mayor frecuencia a los equipos del servicio de endoscopia sobre la correcta limpieza y desinfección de los equipamientos (22)(23) .…”
Section: Resultsunclassified
“…In the institutions where the automated method was adopted, most of the professionals were unaware that the elevator mechanism should remain upright throughout the process, in order to allow greater contact with the cleaning and disinfection solutions (3,14) . The inadequate position of this device deserves to be highlighted due to its potential accumulation of dirt and microorganisms, especially on its posterior face, which may favor maintenance of microorganisms in the structure (22) .…”
Section: Discussionmentioning
confidence: 99%
“…Such findings give rise to a special look at this stage of the process, as the professionals' non-perception of the elevator mechanism as a threat to safe use of the duodenoscopes is a matter of concern (23) , as failures during its processing have been attributed as important causes of several infectious outbreaks, with involvement of numerous patients in different countries in the world (16,(24)(25) . This lack of knowledge reinforces the need to train Endoscopy teams more frequently on correct cleaning and disinfection of these devices (22)(23) .…”
Section: Discussionmentioning
confidence: 99%
“…Ainda na contramão das recomendações científicas, a fim de permitir um maior contato com soluções de limpeza e de desinfecção (3,14) . A posição inadequada deste dispositivo merece destaque em virtude de seu potencial acúmulo de sujidade e microrganismos, especialmente em sua face posterior, podendo favorecer a manutenção de microrganismos na estrutura (22) .…”
Section: Aspectos éTicosunclassified