While this diet does not replace conventional antineoplastic treatments, these preliminary results suggest a potential for clinical application which merits further research.
The murine IgG3 monoclonal antibody (MoAb) 3F8, specific for the ganglioside GD2, activates human complement, is active in antibody-dependent cell-mediated cytotoxicity (ADCC), and can target specifically to human neuroblastoma in patients with metastatic disease. In a phase I study, 3F8 was administered intravenously (IV) to 17 patients with metastatic GD2 positive neuroblastoma or malignant melanoma at doses of 5, 20, 50, and 100 mg/m2. Serum 3F8 levels achieved were proportional to the dose of 3F8 infused. However, serum antimouse antibody levels did not increase with the amount of 3F8 administered. Toxicities included pain, hypertension, urticaria, and complement depletion. All acute side effects were controllable with symptomatic therapy. No long-term side effects were detected in patients observed for more than 14 months. None of the 17 patients received any antitumor therapy postantibody treatment. Antitumor responses occurred in seven of 17 patients. These ranged from complete clinical remissions to mixed responses. The murine monoclonal antibody (MoAb) 3F8 has clinical utility for the diagnosis and therapy of neuroblastoma and melanoma.
Cervical cancers have a high avidity for FDG. The use of PET-FDG scanning accurately predicts both the presence and absence of pelvic and para-aortic nodal metastatic disease.
Although H2(15)O is widely used for CBF measurement by positron tomography, it underestimates CBF, especially at elevated flow rates. Several tracers, including butanol, overcome this problem, but the short half-life of 15O provides advantages that cause water to remain the tracer of choice. We report the first use and evaluation of 15O-labeled butanol for CBF measurement. Flow measurements made in a similar fashion with water and butanol at 10-min intervals were compared in normal volunteers under resting and hypercapnic conditions. Regional analysis showed good agreement between the tracers at low flows, and significant underestimation of flow by water relative to butanol in regions of elevated flow. The observed relationship between the tracers and the curve-fitted permeability-surface area product for water (133 ml.100 g-1.min-1) follow the known relationship between water and true flow. These observations indicate that [15O]-butanol provided accurate measurements of human regional CBF under conditions of elevated perfusion. We conclude that butanol is a convenient and accurate method for routine CBF determination by positron emission tomography.
The effect of different mAs settings on computed tomobraphy (CT) image quality was evaluated by a clinical study and phantom studies. In the clinical portion of this study, a number of CT images, obtained at various mAs settings, were reviewed by experienced CT interpreters. From these same images, graphs were charted of the root-mean-standard deviation (RMSD) vs. body size; there appeared to be a linear relationship between noise, as measured by RMSD, and body size. A performance phantom was used to evaluate the effect of the different mAs settings on resolution. There was some loss in low contrast resolution at 6 and 20 mAs; however, the resolution was identical at 40 and 100 mAs.
Elimination of artifactual accumulation of FDG in the colon and urinary system is essential if primary cancer, associated adenopathy, or subtle recurrences are to be evaluated in FDG PET imaging of the abdomen and pelvis.
The antibody 3F8, an IgG3 murine monoclonal antibody (MoAb) against disialoganglioside GD2, could target iodine-131 (131I) to established subcutaneous human neuroblastoma (NB) xenografts in BALB/c nude mice. 131I-radiolabeled MoAb (0.125-1 mCi) was injected iv. Tumor radioactivity over time was calculated from scintigraphy, and radiation dose to individual tumors was calculated. Tumor shrinkage occurred only with 131I-labeled 3F8, but not with nonradioactive 3F8 or radiolabeled irrelevant antibody. While the tumor of the control mice enlarged by tenfold, the treated tumor showed over 95% shrinkage by 12 days. Both the rate of shrinkage and duration of tumor response were dose dependent. Calculated doses of more than 10,000 rad could be achieved. Only those tumors that received more than 4,200 rad were completely ablated without recurrence. Recurrent tumors were not antigen negative or radioresistant. These results confirmed the prediction based on imaging studies that human NB xenografts could be effectively eradicated with the use of 131I-labeled MoAb 3F8 with tolerable toxicities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.